Daikin 3MXS40K2V1B, 3MXS40K3V1B, 3MXS52E4V1B, 3AMX52E4V1B Installation manuals

0 (0)

INSTALLATION MANUAL

R410A Split Series

Models

3MXS40K2V1B 2AMX52E2V1B 3MXS40K3V1B 2AMX52E3V1B 2MXS52E2V1B 3MKS50E2V1B 2MXS52E3V1B 3MKS50E3V1B 3MXS52E2V1B 4MKS58E2V1B 3MXS52E3V1B 4MKS58E3V1B 3MXS52E4V1B

3AMX52E2V1B

3AMX52E3V1B

3AMX52E4V1B

Installation manual

R410A Split series

Installationsanleitung

Split-Baureihe R410A

Manuel d’installation

Série split R410A

Montagehandleiding

R410A Split-systeem

Manual de instalación

Serie Split R410A

Manuale d’installazione

Serie Multiambienti R410A

Εγχειρßδιο εγκατÜστασηò διαιροýìενηò σειρÜò R410A

Manual de Instalação

Série split R410A

Рóêоводство по монтажó Серия R410A с раздельной óстановêой

Montaj kýlavuzlarý

R410A Split serisi

English

Deutsch

Français

Nederlands

Español

Italiano

ΕλληνικÜ

Portugues

Рóссêий

Türkçe

DAIKIN INDUSTRIES, LTD.

3MXS40K2V1B

<![if ! IE]>

<![endif]>17J-3SB64564

Low Voltage 2006/95/EC

Electromagnetic Compatibility 2004/108/EC *

DAIKIN.TCF.015 N20/09-2011

DEKRA Certification B.V. (NB0344)

74736-KRQ/EMC97-4957

Shinri Sada

Manager Quality Control Department

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

Kita-ku, Osaka, 530-8323 Japan

DAIKIN INDUSTRIES, LTD.

2MXS52E2V1B, 2AMX52E2V1B, 3MXS52E2V1B, 3AMX52E2V1B, 3MKS50E2V1B, 4MKS58E2V1B, 2MXS52E3V1B, 2AMX52E3V1B, 3MXS52E3V1B, 3AMX52E3V1B, 3MKS50E3V1B, 4MKS58E3V1B

<![if ! IE]>

<![endif]>1-3SB64564

Low Voltage 2006/95/EC

Electromagnetic Compatibility 2004/108/EC *

DAIKIN.TCF.015 K1/07-2007

KEMA Quality B.V.

74736-KRQ/EMC97-4957

Shinri Sada

Manager Quality Control Department

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

1st. of Dec. 2008

Kita-ku, Osaka, 530-8323 Japan

3MXS40K2V1B, 2MXS52E2V1B, 2AMX52E2V1B, 3MXS52E2V1B, 3AMX52E2V1B, 3MKS50E2V1B, 4MKS58E2V1B, 2MXS52E3V1B, 2AMX52E3V1B, 3MXS52E3V1B, 3AMX52E3V1B, 3MKS50E3V1B, 4MKS58E3V1B

<![if ! IE]>

<![endif]>5A-3SB65451

Shinri Sada

Manager Quality Control Department

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

Kita-ku, Osaka, 530-8323 Japan

DAIKIN INDUSTRIES, LTD.

3MXS40K3V1B, 3MXS52E4V1B, 3AMX52E4V1B

EN60335-2-40,

<![if ! IE]>

<![endif]>9D-3SB65451

Low Voltage 2006/95/EC

Machinery 2006/42/EC **

Electromagnetic Compatibility 2004/108/EC *

DAIKIN.TCF.015 P6/07-2012

DEKRA Certification B.V. (NB0344)

74736-KRQ/EMC97-4957

Shinri Sada

 

Manager Quality Control Department

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

 

 

Kita-ku, Osaka, 530-8323 Japan

,,

Daikin 3MXS40K2V1B, 3MXS40K3V1B, 3MXS52E4V1B, 3AMX52E4V1B Installation manuals

Safety Precautions

The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.

Meaning of WARNING and CAUTION notices

WARNING .............

Failure to follow these instructions properly may result in personal injury or loss of life.

CAUTION ..............

Failure to observe these instructions properly may result in property damage or personal injury,

 

which may be serious depending on the circumstances.

• The safety marks shown in this manual have the following meanings:

Be sure to follow the instructions.

Be sure to establish an earth connection.

Never attempt.

 

 

 

After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation manual.

WARNING

• Ask your dealer or qualified personnel to carry out installation work.

Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.

• Install the air conditioner in accordance with the instructions in this installation manual.

Improper installation may result in water leakage, electric shocks or fire.

• Be sure to use only the specified accessories and parts for installation work.

Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.

• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.

A foundation of insufficient strength may result in the equipment falling and causing injury.

• Electrical work must be performed in accordance with relevant local and national regulations and with instructions in this installation manual. Be sure to use a dedicated power supply circuit only.

Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.

• Use a cable of suitable length.

Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.

• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or wires.

Improper connections or securing of wires may result in abnormal heat build-up or fire.

• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires so that the control box lid can be securely fastened.

Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.

• If refrigerant gas leaks during installation, ventilate the area immediately.

Toxic gas may be produced if the refrigerant comes into contact with fire.

• After completing installation, check for refrigerant gas leakage.

Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.

• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and use only the specified refrigerant (R410A).

The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury.

• During installation, attach the refrigerant piping securely before running the compressor.

If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.

• During pump-down, stop the compressor before removing the refrigerant piping.

If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.

• Be sure to earth the air conditioner.

Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.

• Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may result in electric shocks or fire.

CAUTION

• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.

In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.

• While following the instructions in this installation manual, install drain piping to ensure proper drainage and insulate piping to prevent condensation.

Improper drain piping may result in indoor water leakage and property damage.

• Tighten the flare nut according to the specified method such as with a torque wrench.

If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.

• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.

Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.

The temperature of refrigerant circuit will be high, please keep the inter-unit wire away from copper pipes that are not thermally insulated.

■English

1