Bosch DWW091451A Installation Manual

Operating and installation instructions

Fig. 1

Abb. 1

GAZ

ELECTRO

mind.

mind.

650

550

2

Operating Instructions

 

Appliance description

 

 

Chimney

 

panelling

 

Light / fan

 

switches

Filter grille

Lighting

Operating modes

Exhaust-air mode:

The extractor-hood fan extracts the kitchen vapours and conveys them through the grease filter into the atmosphere.

The grease filter absorbs the solid particles in the kitchen vapours.

The kitchen is kept almost free of grease and odours.

DWhen the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion.

Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar).

Operating modes

This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air- intake/exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc.

If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room.

An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.

Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens.

Unrestricted operation is possible if the extractor hood is used in recirculating mode

– with activated carbon filter.

Circulating-air mode:

An activated carbon filter must be fitted for this operating mode (see Filters and

maintenance).

The complete installation set and replacement filters can be obtained from specialist outlets.

The corresponding accessory numbers can be found at the end of these operating instructions.

The extractor-hood fan extracts the kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen.

The grease filter absorbs the grease particles in the kitchen vapours.

The activated carbon filter binds the odorous substances.

If no activated carbon filter is installed, it is not possible to bind the odorous substances in the cooking vapours.

3

Before using for the first time

Important notes:

The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance.

This extractor hood complies with all relevant safety regulations.

Repairs should be carried out by qualified technicians only.

Improper repairs may put the user at considerable risk.

Before using your appliance for the first time, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance.

Please retain the operating and installation instructions for a subsequent owner.

This appliance is labelled

in accordance with European Directive 2002/96/EG concerning used electrical and

electronic appliances (waste electrical and electronic equipment – WEEE). The guideline

determines the framework for the return and recycling of used appliances as applicable throughout the EU.

If you encounter a problem

If you have any questions or if a fault occurs, please call Customer Service.

(See list of Customer Service representatives).

When you call, please quote the following:

E-Nr. FD

Enter the relevant numbers into the box above. The E-Nr. (product no.) and FD (production date) are shown on the nameplate which can be seen inside the extractor hood after the filter frame has been detached.

The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework.

4

Safety instructions

Do not use the appliance if damaged.

The appliance may be connected to the mains by a qualified technician only.

The appliance is not intended for use by young children or infirmed persons

without supervision.

Young children should be supervised to ensure they do not play with the appliance.

If the connecting cable for this

appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.

Dispose of packaging materials properly (see Installation instructions).

This extractor hood is designed for domestic use only.

Light bulbs must always be fitted when the extractor hood is in use.

Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading.

Never operate the extractor hood without a grease filter.

Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended.

Never allow children to play with the appliance.

Do not let adults or children operate the appliance unsupervised:

if they are mentally or physically unable to use the appliance safely and correctly,

if they don’t have the knowledge and experience to use the appliance safely and correctly.

Do not flambé food directly under the extractor hood.

!Risk of grease filter catching fire due to flames.

The hotplates must always be covered with a utensil.

Restrictions apply to the use of the extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions).

Gas hobs / Gas cookers

Do not use all the gas hotplates simultaneously for a prolonged period (max. 15 minutes) at maximum thermal load, otherwise there is a risk of burns if the housing surfaces are touched or a risk of damage to the extractor hood. If the extractor hood is situated over a gas hob, operate the hood at maximum setting if three or more gas hotplates are operated simultaneously.