ZyXEL NetAtlas Workgroup User Manual

NetAtlas Workgroup
Ethernet Switch Manager
Quick Start Guide
Version 1.03
Edition 1
1/2007
NetAtlas Workgroup Quick Start Guide
The NetAtlas Workgroup Ethernet Switch Manager is an Element Management System (EMS) that retrieves management information from switches using the SNMP protocol. The EMS allows you to manage multiple switches from a central location.
This guide shows you how to install NetAtlas Workgroup. Refer to the user’s guide for background and configuration information.

2 Minimum System Requirements

• CPU: Intel Pentium 4, 1.6 GHz or faster
• Memory (RAM): 1 GB or more
• Hard Disk free space: 20 GB or more
• Screen Resolution: 1024 x 768 pixels
• Ethernet Adaptor: 10/100 Mbps
• Operating System (using NTFS file system): Windows 2000 (service pack 1), Windows Professional, Windows XP or Windows Server 2003.
• Database Program: PostgreSQL 8.0.
• Castle Rock’s SNMPc Network Manager 7.0.14.

2.1 Installation Overview

The following gives an overview of what you need to do to install the EMS:
1 Install EMS server.
Note: The installation program will install or upgrade PostgreSQL
and SNMPc if they are not installed or are of an older version than the minimum requirement.
2 Compile MIBs.
3 Add device(s) that you want the EMS to manage.
4 If required, configure the ODBC (Open DataBase Connectivity)
driver to connect to the EMS database.
2
NetAtlas Workgroup Quick Start Guide

3 Install EMS Server

Follow the steps below to install the EMS server on a computer.
Note: Follow the directions in the wizard to proceed through the
installation. Only screens that require input specific to the EMS Workgroup installation are shown.
1 Find and double-click
NetAtlasWorkgroup_S103.exe on
the installation CD.
2 A Welcome screen displays. Click
Next to proceed to the License Agreement Screen.
Read the license agreement. Click
Yes to accept the agreement.
3 A screen displays indicating
whether SNMPc or PostgreSQL installation/upgrade is required. Click Next.
If you need to install/upgrade SNMPc, you see the screen as shown in Step 4.
If you need to install/upgrade PostgreSQL, you see the screen as shown in Step 7.
Otherwise, you see the screen as shown in Step 15.
4 A screen displays. Click Next to
proceed to install/upgrade SNMPc.
Follow the directions in the SNMPc installation wizard until you enter the Discovery Seed screen.
3
NetAtlas Workgroup Quick Start Guide
5 You can set the SNMPc to
automatically locate your ZyXEL switch(es). Specify the IP address, subnet mask and community (or password) of a device as the starting point. Make sure the IP address and subnet mask of this device and your ZyXEL switch are in the same range.
Select Start with Discovery Off to manually add a ZyXEL switch after initial setup.
6 Continue through the wizard a
screen appears to confirm a successful installation of SNMPc
7.0. Click OK
7 If you need to install/upgrade
PostgreSQL, you see the screen as shown here. Click Next to continue.
Otherwise, you see the screen as shown in Step 15.
8 Specify where you want to install
PostgreSQL. Accept the default file directory or click Browse to specify a new location.
Follow the directions in the next screens until you enter the Installation Options screen of PostgreSQL installation.
4
NetAtlas Workgroup Quick Start Guide
9 Specify the installation options.
Make sure you install in the same file location as specified in Step 8. Click Next to continue.
10 Accept the default or specify the
account user name and password that allows the PostgreSQL to run on your computer. The default password is “PostgreSQLDB”.
Note: This is NOT a Windows login
account. The account user name and password are case­sensitive.
11 Click Yes to create a new
account and then click OK to continue.
12 Specify the database cluster
settings and create the administrator (root) account.
5
NetAtlas Workgroup Quick Start Guide
13 Accept the default setting and click
Next to continue.
14 Select additional function(s) for the
database.
Note: Do NOT clear the DBsize or
pgAdmin Support option.
Continue through the installation and click Finish when you get to the final PostgreSQL screen.
15 EMS installation automatically
continues and initializes database connections.
16 When the EMS installation process
is complete, a screen displays as shown. Click Finish.
6
NetAtlas Workgroup Quick Start Guide

4 SNMPc Network Manager Startup

To start the SNMPc Network Manager manually, use the Windows Start menu.
To start SNMPc automatically each time you turn on your computer, click
Config, System Startup, select Auto Startup and then click OK.
Conversely, clear this check box if you do not wish SNMPc to automatically start each time you turn on your computer.

5 Compile MIBs

Management Information Base (MIB) is designed for holding management information on systems. ZyXEL private MIBs contains information for devices that the standard MIB does not include. During the EMS installation, ZyXEL private MIBs are automatically added into the SNMPc MIB database.
1 From the SNMPc Network Manager
main screen, click Config, MIB
Database.
2 Click Compile in the Compile Mibs
screen.
3 Click Yes when asked to confirm, then
click OK.
4 Finally click Done in the Compile Mibs screen.

6 Add Your Device

The SNMPc Network Manager is able to find new devices automatically using auto-discovery (enabled by default) or you can add device(s) manually.
7
NetAtlas Workgroup Quick Start Guide

6.1 Device Auto-Discovery

1 To enable auto-discovery and then
find your device, click Config, Discovery/Polling.
2 Select the Enable Discovery check
box and click OK.
3 Find your device in the Device List
panel. Double-click the device icon to access the EMS.

6.2 Add Device(s) Manually

Follow the steps below to add your device(s) manually.
1 Click Insert, MAP Object, Device.
2 In the MAP Object Properties
screen, enter a descriptive device name and IP address for the device and then click OK.
3 Click the Access tab.
4 For initial setup, configure the
specified fields to the default values listed in the table below.
Field Value
Read Access Mode SNMP V2c
Read/Write Access Mode SNMP V2c
Read, Read/Write and
public
Trap communities
8
NetAtlas Workgroup Quick Start Guide
Note: For security purposes, it is strongly recommended you
change the Read Community and Read/Write Community defaults and store this information in a secure place so you will not forget it later.
5 After the device has been found, an
icon and label appear in the network manager view window.
6 Right-click on the device icon to
view a set of SNMPc network manager shortcuts. Click Properties to verify the information you entered in Step 4.
Note: Make sure PostgreSQL
database is running. PostgreSQL should start automatically when you start Windows. If it does not, click
Start (or start), Programs, PostgreSQL 8.0 and then click Start service.

7 Access the EMS

To access the EMS, double-click a ZyXEL device icon in the SNMPc main screen. Click the Switch Manager icon to display the main EMS screen.
You have successfully installed the EMS. Refer to the user’s guide for configuration information.
9
NetAtlas Workgroup Quick Start Guide

7.1 Database Synchronization

If you upgrade EMS from a previous version, the Database Synchronization screen displays when you try to access the EMS. You can use this screen to back up the database from a previous EMS version using the new database format.
1 If you want to import the
database from a previous EMS version into SNMPc, select Yes.
Select No if you have created objects in SNMPc for your ZyXEL devices and you want to have the EMS automatically obtain device information from SNMPc.
2 In the Backup Directory field, click Browse to specify a location to
back up the database from a previous EMS version using the new database format.
3 In the Backup Name field, enter a descriptive name for the file.
4 Click OK to continue.
Note: Database backup using the new database format allows you
to restore data from a previous EMS version. You cannot restore information from a backup database with the old database format.
Troubleshooting
1 EMS, SNMPc and/or PostgreSQL will not install properly
• Make sure that the computer on which you are installing EMS meets the minimum hardware and software requirements. Refer to Section 2 on page 2.
• Before installing PostgreSQL, make sure your computer is using the NTFS file system. To check your computer’s file system, right-click on a drive in Windows Explorer and click Properties.
• Shut down any running services or applications which may affect the installation.
10
NetAtlas Workgroup Quick Start Guide
• Remove any previous versions of PostgreSQL from your com­puter. See Step 3.
• Re-install PostgreSQL and EMS in that order. See Step 3.
2 I cannot find my device in the SNMPc Management screen.
• Check that you have compiled the MIBs without errors (see Sec-
tion 5 on page 7).
• Check that you have enabled auto-discovery; see Section 4 on
page 7.
• Check that the map object properties are correct for initial setup; see Section 6.2 on page 8. Make sure the IP address entered is the IP address of the switch you want to manage via the EMS.
• Check that the ODBC driver is correctly configured; see the next section.
• Make sure that PostgreSQL is running.
• Make sure that the computer on which you have installed the EMS is connected to the network where the switch is located.
• Make sure the ZyXEL switch is turned on.
• Make sure your computer’s Ethernet card is working properly.
• If the problem still persists, uninstall and re-install the EMS, see
Step 3.
3 Uninstalling and Reinstalling EMS and its required components.
• If you encounter problems with your software or one of its com­ponents you can try uninstalling and reinstalling EMS or one of its components.
• Find and double-click NetAtlasWorkgroup_S103.exe on the installation CD. The fol­lowing screen appears.
• Follow the unscreen directions to uninstall any of the components.
11
NetAtlas Workgroup Quick Start Guide
Configure the ODBC Driver
The ODBC driver should already be installed during the EMS installation process. If you have changed the default ODBC settings, make sure the EMS can connect to the PostgreSQL database successfully.
Follow the steps below to configure the ODBC driver in Windows 2000. Steps are similar for other supported Windows operating systems.
1 Click Start, Settings and Control
Panel to open the Control Panel
screen. Double-click
Administrative Tools.
2 Double-click Data Source (ODBC).
3 A screen displays as shown. Click
the System DNS screen, select EnterpriseEMS and click Configure.
4 The PostgreSQL ODBC
Driver Setup screen
displays. Configure the fields exactly as listed in the table below.
Field Value
Database EnterpriseEMS
Server localhost
Port 5432
User Name root
Password 1234
Note: The field values are case-sensitive.
5 Click Save to save the changes and close this screen.
12