Whirlpool JES1450D, WEC530H0D, YIEL730C, JIS1450CD, YWEE730H0D Installation Instructions Manual

...
0 (0)
INSTALLATION INSTRUCTIONS
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10665255A
30" (76.0 CM) SLIDE-IN ELECTRIC RANGES
INSTRUCTIONS D’INSTALLATION DES CUISINIÈRES
ÉLECTRIQUES ENCASTRABLES DE 30" (76,0 CM)
Table of Contents/Table des matières
RANGE SAFETY .............................................................................2
INSTALLATION REQUIREMENTS................................................3
Tools and Parts ............................................................................3
Electrical Requirements - U.S.A. Only.........................................6
Electrical Requirements - Canada Only.......................................7
INSTALLATION INSTRUCTIONS..................................................8
Unpack Range..............................................................................8
Install Anti-Tip Bracket.................................................................8
Adjust Leveling Legs....................................................................9
Level Range................................................................................10
Electrical Connection - U.S.A. Only...........................................10
Verify Anti-Tip Bracket is Installed and Engaged ......................15
Remove/Replace Drawer...........................................................16
Oven Door ..................................................................................16
Complete Installation .................................................................17
SÉCURITÉ DE LA CUISINIÈRE ...................................................19
EXIGENCES D’INSTALLATION...................................................20
Outillage et pièces......................................................................20
Exigences d’emplacement.........................................................20
Spécifications électriques – Canada seulement........................23
INSTRUCTIONS D’INSTALLATION.............................................24
Déballage de la cuisinière ..........................................................24
Installation de la bride antibasculement ....................................24
Réglage des pieds de nivellement .............................................25
Réglage de l’aplomb de la cuisinière.........................................26
Vérifier que la bride antibasculement
est bien installée et engagée......................................................26
Dépose et repose du tiroir..........................................................27
Porte du four...............................................................................27
Achever l’installation ..................................................................28
RANGE SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
Tip Over Hazard A child or adult can tip the range and be killed. Install anti-tip bracket to floor or wall per installation instructions. Slide range back so rear range foot is engaged in the slot of the anti-tip bracket. Re-engage anti-tip bracket if range is moved. Do not operate range without anti-tip bracket installed and engaged. Failure to follow these instructions can result in death or serious burns to children and adults.
Anti-Tip Bracket
To verify the anti-tip bracket is installed and engaged:
Slide range forward.
Look for the anti-tip bracket securely attached to floor or wall.
Slide range back so rear range foot is under anti-tip bracket.
See installation instructions for details.
Range Foot
WARNING
2
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools needed
Tape m e a s ure
Flat-blade screwdriver
Phillips screwdriver
Level
Hand or electric drill
Wrench or pliers
Marker or pencil
Parts supplied
Check that all parts are included.
3 - 10-32 hex nuts (attached to terminal block)
3 - Direct wire lugs
2 - #10 x 1⁵⁄₈" (4.1 cm) screws (for mounting anti-tip bracket)
Anti-tip bracket (inside oven cavity)
Anti-tip bracket must be securely mounted to the back wall or floor. Thickness of flooring may require longer screws to anchor bracket to subfloor. Longer screws are available from your local hardware store.
For model:
IEL730C WEC530H0D WEE730H0D YIEL730C YWEE730H0D
Oven racks 23
Parts needed
If using a power supply cord kit:
A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening and must end in ring terminals or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes. Check existing electrical supply. See the appropriate “Electrical Requirements” section.
It is recommended that all electrical connections be made by a licensed, qualified electrical installer.
Masking tape
¼" (13 mm) drive ratchet
¼" (13 mm) nut driver
³⁄₈" (10 mm) and ⁵⁄₁₆" (8 mm)
nut driver
¹⁄₈" (3 mm) drill bit (for wood
floors)
Tin snips or large wire
cutters (for cutting ground strap if necessary)
JES1450CD JES1450D JIS1450CD JIS1450D KSEG700E KSEB900E KSIB900E MES8880D WEE760H0D YKSEG700E YKSEB900E YKSIB900E YMES8880D YWEE760H0D
Optional Parts
To purchase these or any other accessories, please reference the “Accessories” section of the User Guide for contact information.
Side Trim Kits:
White - Order Part Number W10677527 Black - Order Part Number W10675026 Stainless Steel - Order Part Number W10675028
Backsplash Kits:
High 6" (15.2 cm) White - Order Part Number W10655448 High 6" (15.2 cm) Black - Order Part Number W10655449 High 6" (15.2 cm) Stainless Steel - Order Part Number W10655450
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the oven door on the top right-hand side of the oven frame.
The range should be located for convenient use in the
kitchen.
Recessed installations must provide complete enclosure of
the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood or microwave hood combination that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
All openings in the wall or floor where range is to be installed
must be sealed.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
The anti-tip bracket must be installed. To install the anti-tip
bracket shipped with the range, see “Install Anti-Tip Bracket” section.
Grounded electrical supply is required. See the appropriate
“Electrical Requirements” section.
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
Use an insulated pad or ¼" (0.64 cm) plywood under range if
installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
3
Mobile Home - Additional Installation Requirements
B
D
A
F
E
C
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the current standards CAN/CSA-A240-latest edition, or with local codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.
Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to be revised. See “Electrical Connection - U.S.A. Only” section.
Product Dimensions
This manual covers several models. Your model may appear different from the models depicted. Dimensions given are maximum dimensions across all models.
Model KSEB900
A. 1
³⁄₁₆
" (3.0 cm) height from
cooktop to top of vent
B. 29
⁷⁄₈
" (75.9 cm)
C. Model/serial number plate
(located behind the oven door on the top right-hand side of the oven frame)
D. 36" (91.4 cm) height to top of
cooktop edge with leveling legs screwed all the way in*
E. 28
⁵⁄₁₆
" (71.9 cm) max. depth from front of console to back of range.
F. 2 8
⁷⁄₈
" (73.3 cm) max. depth from handle to back of range.
IMPORTANT: Range must be level after installation. Follow the instructions in the “Level Range” section. Using the cooktop as a reference for leveling the range is not recommended.
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
4
Cabinet Dimensions
K
A
B
C
D
E
G
H
I
J
F
I
L
K
A
B
C
D
E
G
H
I
J
F
I
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Range may be installed next to combustible walls with zero clearance.
NOTE: When installed in a slide-in cutout, the front of oven door may protrude beyond the base cabinet. Slide-in Cutout Freestanding cutout
A. 18" (45.7 cm) upper side cabinet to countertop B. 13" (33 cm) max. upper cabinet depth C. 30" (76.2 cm) min. opening width D. For minimum clearance to top of cooktop, see NOTE*. E. In U.S.A.: 30" (76.2 cm) min. opening width
In Canada: 31" (78.7 cm) min. opening width
F. The shaded area is recommended for installation of grounded
outlet.
G. 13
¹⁄₈
" (33.3 cm)
H. 7
¹¹⁄₁₆
" (19.5 cm)
I. 4
¹³⁄₁₆
" (12.2 cm)
J. 3
¹¹⁄₁₆
" (9.4 cm) or measurement of L, whichever is greater
K. Cabinet door or hinges should not extend into the cutout.
L. Remaining counter depth should not exceed 2¼" (5.7 cm)
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is shielded by not less than ¹⁄₄" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth C. 30" (76.2 cm) min. opening width D. For minimum clearance to top of cooktop, see NOTE*.
E. In U.S.A.: 30" (76.2 cm) min. opening width
In Canada: 31" (78.7 cm) min. opening width
F. The shaded area is recommended for installation of grounded
outlet.
G. 13
¹⁄₈
" (33.3 cm)
H. 7
¹¹⁄₁₆
" (19.5 cm)
I. 4
¹³⁄₁₆
" (12.2 cm)
J. 3
¹¹⁄₁₆
" (9.4 cm)
K. Cabinet door or hinges should not extend into the cutout.
5
Electrical Requirements - U.S.A. Only
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes.
Do not use an extension cord. Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/ NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service technician if you are in doubt as to whether the appliance is properly grounded. Do not modify the power supply cord plug. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating plate. The model/serial rating plate is located behind the oven door on the top right-hand side of the oven frame.
This range is manufactured with the neutral terminal
connected to the cabinet. Use a 3-wire, UL listed, 40- or 50-amp power supply cord (pigtail) (see the following Range Rating chart). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40- or 50-amps and investigated for use with ranges.
Range Rating* Specified Rating of
Power Supply Cord Kit and Circuit Protection
120/240 Volts 120/208 Volts Amps
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt, 40- or 50-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire receptacle (10-50R)
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the neutral by a link. The ground must be revised so the green ground wire of the 4-wire power supply cord is connected to the cabinet. See “Electrical Connection - U.S.A. Only” section.
Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50P plug on the supply end.
The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50** 50
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker
box (or fused disconnect) through flexible or nonmetallic sheathed, copper or aluminum cable. See the “Electrical Connection - U.S.A. Only” section.
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction box).
Wire sizes and connections must conform with the rating of
the range.
The tech sheet and wiring diagram are located on the back of
the range in a plastic bag.
6
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power cord are:
40-amp circuit 2 No.-8 conductors 1 No.-10 white neutral 1 No.-10 green grounding
Electrical Requirements - Canada Only
WARNING
Electrical Shock Hazard Electrically ground range. Failure to do so can result in death, fire, or
electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge are in accordance with local codes.
Be sure that the electrical connection and wire size are adequate and in conformance with CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
Range Rating* Specified Rating of
Power Supply Cord Kit and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of range’s final location.
Do not use an extension cord.
The tech sheet and wiring diagram are located on the back of
the range in a plastic bag.
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50** 50
7
INSTALLATION INSTRUCTIONS
WARNING
Excessive Weight Hazard
Use two or more people to move and install range. Failure to do so can result in back or other injury.
WARNING
Tip Over Hazard A child or adult can tip the range and be killed. Install anti-tip bracket to floor or wall per installation
instructions. Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket. Re-engage anti-tip bracket if range is moved. Do not operate range without anti-tip bracket installed
and engaged. Failure to follow these instructions can result in death
or serious burns to children and adults.
Centerline
A
B
Unpack Range
1. Remove shipping materials, tape and film from the range.
Keep cardboard bottom under range. Do not dispose of anything until the installation is complete.
2. Remove oven racks and parts package from oven and
shipping materials.
3. To remove cardboard bottom, first take 4 cardboard corners
from the carton. Stack one cardboard corner on top of another. Repeat with the other 2 corners. Place them lengthwise on the floor behind the range to support the range when it is laid on its back.
4. Using 2 or more people, firmly grasp the range and gently lay
it on its back on the cardboard corners.
5. Remove cardboard bottom. The leveling legs can be adjusted while the range is on its back.
See the “Adjust Leveling Legs” section. NOTE: To place range back up into a standing position, put a
sheet of cardboard or hardboard on the floor in front of range to protect the flooring. Using 2 or more people, stand range back up onto the cardboard or hardboard.
Install Anti-Tip Bracket
1. Remove the anti-tip bracket from the inside of the oven.
2. Determine which mounting method to use: floor or wall.
If you have a stone or masonry floor, you can use the wall mounting method. If you are installing the range in a mobile home, you must secure the range to the floor.
This anti-tip bracket and screws can be used with wood or metal studs.
3. Determine and mark centerline of the cutout space. The
mounting can be installed on either the left side or right side of the cutout. Position mounting bracket against the wall in the cutout so that the V-notch of the bracket is 12½" (31.8 cm) from centerline as shown.
8
A. 12½" (31.8 cm) B. Bracket V-notch
4. Drill two ¹⁄₈" (3 mm) holes that correspond to the bracket
WARNING
Tip Over Hazard A child or adult can tip the range and be killed. Install anti-tip bracket to floor or wall per installation
instructions. Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket. Re-engage anti-tip bracket if range is moved. Do not operate range without anti-tip bracket installed
and engaged. Failure to follow these instructions can result in death
or serious burns to children and adults.
holes of the determined mounting method. See the following illustrations.
Floor Mounting
Rear position Front position Diagonal (2 options)
Wall Mounting
Adjust Leveling Legs
1. If range height adjustment is necessary, use a wrench or
pliers to loosen the 4 leveling legs. This may be done with the range on its back or with the range
supported on 2 legs after the range has been placed back to a standing position.
NOTE: To place range back up into a standing position, put a sheet of cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto the cardboard or hardboard.
5. Using the Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #10 x 1⁵⁄₈" (4.1 cm) screws provided.
6. Move range close enough to opening to allow for final
electrical connections. Remove shipping base, cardboard or hardboard from under range.
7. Move range into its final location, making sure rear leveling
leg slides into anti-tip bracket.
8. Move range forward onto shipping base, cardboard or
hardboard to continue installing the range using the following installation instructions.
2. Measure the distance from the top of the counter to the floor.
3. Measure the distance from the top of the cooktop to the
bottom of the leveling legs. This distance should be the same. If it is not, adjust the leveling legs to the correct height. The leveling legs can be loosened to add up to a maximum of 1" (2.5 cm). A minimum of ³⁄₁₆" (5 mm) is needed to engage the anti-tip bracket.
NOTE: If height adjustment is made when range is standing, tilt the range back to adjust the front legs, then tilt forward to adjust the rear legs.
4. When the range is at the correct height, check that there is
adequate clearance under the range for the anti-tip bracket. Before sliding range into its final location, check that the anti­tip bracket will slide under the range and onto the rear leveling leg prior to anti-tip bracket installation.
NOTE: If a Trim Kit will be used, the top of the cooktop should be higher than the counter. See the Installation Instructions included with the Trim Kit for the correct height.
9
Level Range
WARNING
Electrical Shock Hazard Disconnect power before servicing. Use a new 40 amp power supply cord. Plug into a grounded outlet. Failure to follow these instructions can result in death,
fire, or electrical shock.
A
B
C
1. Place level on the oven bottom as indicated in one of the two
figures below depending on the size of the level. Check with the level side to side and front to back.
2. If range is not level, use a wrench or pliers to adjust leveling
legs up or down until the range is level. NOTE: Range must be level for satisfactory baking
performance and best cleaning results using AquaLift Self-Clean Technology.
®
Electrical Connection - U.S.A. Only
If your home has a 3- or 4-wire receptacle, continue with “Install Using a Power Supply Cord.” If your home has a 3- or 4-wire direct connection, go to “Install Using Direct Wire.”
Install Using a Power Supply Cord
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Assemble a UL listed strain relief in the opening.
A
Power supply cord strain relief
1. Disconnect power.
2. Remove the lower access cover screws located on the back
of the range. Pull the bottom of the cover toward you and out to remove cover from range.
A. UL listed strain relief
5. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended) 3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has: And you will be
connecting to:
3-wire receptacle (NEMA type 10-50R)
4-wire receptacle (NEMA type 14-50R)
A UL listed, 250-volt minimum, 40- or 50-amp, range power supply cord
A UL listed, 250-volt minimum, 40- or 50-amp, range power supply cord
Go to Section:
3-wire connection: Power supply cord
4-wire connection: Power supply cord
10
A. Three mounting tabs B. Lower access cover C. Screws (2)
Loading...
+ 22 hidden pages