– 17 –
FILE NO. SVM-05016
4-3. Outdoor Unit (RAS-18UAH-E4)
4-4. Indoor Unit (RAS-24NKD-E4, RAS-24NKDX4, RAS-24NKD-AR4, RAS-24NKDX4-T,
RAS-18NKD-E4, RAS-18NKDX4, RAS-18NKD-AR4, RAS-18NKDX4-T2)
No. Parts name Type Specifications
1 Fan motor (for indoor) AFS-220-31A AC 200 − 240V, 31W
2 Thermo sensor (TA-sensor) ——— 10 kΩ at 25°C
3 Micro Power Module (M01) µRM1260V DC 390 V, Secondary DC 12 V
4 Microcontroller TMP87CM40AN
5 Heat exchanger sensor
——— 10 kΩ at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C63) KMH400VSSN47M22S 4.7µF, 400 V
9 Fuse (F01) BET6.3A T6.3 A, 250 V
10 Varistor (R21, R22) 15G561K 560 V
11 Resistor (R319) RF-2TK5R6 5.6Ω, 2 W
12 Louver motor MP35EA12 Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
13 Relay : (RY04) G5NB-1A Coil DC 12V, 16.7mA, Contact AC 250V, 1A
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor 2JS350D5DA02 Winding resistance (Ω) C-R C-S
(at 20°C) 0.981 2.845
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) KFG6-71SB5P-T3 Winding resistance (Ω) Red-Black White-Black
(at 20°C) 64.4 127.4
3
Running capacitor
451205L AC 450 V, 2µF
(for fan motor)
4
Running capacitor
BUM44X4505B AC 440 V, 45µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 – 240 V
(for 4-way valve)
6 Thermo sensor TE / TD 10 kΩ at 25°C / 50 kΩ at 25°C
7 Magnetic contactor
CLK-26J
220 − 240 V, 50 Hz
8 Transformer TT-05 220 – 240 V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74, R86) 15G471K 470 V
11 Fuse (F01) MT3 T6.3 A, 250 V