- User Brochure
tekmarNet®4 User Switch 481
U 481
06/06
The User Switch
allows for easy and
convenient control of your tN4
heating and cooling systems.
By pressing a single button, you
can:
• Activate a night setback on
the tN4 heating and cooling
system.
• Activate an away override.
• Activate custom programmed
system overrides.
• Activate and deactivate devices
such as hot tubs and radiant
floors.
The user switch also allows for
optional remote access through
a third party telephone switch,
security system, or automation
system.
Table of Contents
User Interface ......................................................... 2
Scenes .................................................................... 2
Setpoint Controls .................................................... 3
Error Messages ...................................................... 4
Warranty ................................................................. 4
User
Button
1
User
Button
2
User
Button
3
1 of 4 © 2005 U 481 - 06/06

User Interface
• Each button is labeled according to the feature that it is programmed to activate.
• When a button is pressed, the button turns green and the programmed feature activates.
• Pressing the button while it is green deactivates the programmed feature.
• In some cases, the installer may have disabled a button. In this case, when the button is pressed,
the button will not turn green.
• Each button can be programmed to activate or deactivate a Scene or a Setpoint Control. Scenes
and Setpoint Controls will be discussed in upcoming sections.
The following list is the button operation configured by the installer:
User Switch Location:
1
2
3
Button Label Name
1
2
3
Note: The installer should complete this table.)
Scenes
Scenes are system overrides. By changing the scene of
the tN4 system, all thermostats and setpoint controls with
scenes turned on are affected.
The button is green when the active scene on the tN4 system
and the programmed setting of the button are the same.
When there are no buttons programmed to the same scene
as the active scene, none of the buttons will be green.
Some scenes are permanent while others are temporary
and last for either 3, 4, or 8 hours. When a temporary scene
expires, the tN4 system returns back to the last permanent
scene. See the “Duration” column in the table to determine
the length of time the scene lasts.
Setpoint
Control
Permanent Temporary
3 hr 4 hr 8 hr
When a button is green, and the button is pressed a
second time, it cancels the current scene. For permanent
scenes, the tN4 system returns to the “Normal” scene. For
temporary scenes, the tN4 system returns to the previous
permanent scene.
There are a total of 8 possible scenes available on the tN4
system. Each user switch can activate up to 3 scenes. In
order to be able to have all 8 scenes, multiple user switches
are required.
Scene (Duration)
Normal
Press
Button
© 2006 U 481 - 06/06 2 of 4
Guest
Away
Scene is activated
Press Button
2nd time to
cancel Scene
Normal
Guest
Away
Permanent Scene
Returns to “Normal”
Scene.
Temporary Scene
Returns to previous
permanent scene

Example
A user switch has been installed together with two thermostats.
The thermostats are located in the master bedroom and
the guest bedroom.
User switch button 1 is labeled “Normal”.
User switch button 2 is labeled “Guest”.
User switch button 3 is labeled “Away”.
The master bedroom is programmed to operate at the
programmable setback schedule while in “Normal” and
“Guest” scenes.
The guest thermostat is programmed to operate at the
unoccupied temperature while in “Normal” scene and at the
programmable setback schedule while in “Guest” scene.
Setpoint Controls
In this example, when a guest arrives to stay the night, the
“Guest” button can be pressed and the Guest Bedroom
temperature will operate on a programmable setback
schedule.
Once the guest leaves, press the “Normal” button to lower the
Guest Bedroom to the unoccupied temperature setting.
The following table shows how the thermostats respond
to each button:
Button
Master Bedroom
Action
Guest Bedroom
Action
“Normal” Setback Schedule Unoccupied
“Guest” Setback Schedule Setback Schedule
“Away” Away Away
In addition to scenes, the user switch can also be programmed
to enable and disable individual setpoint controls or groups
of setpoint controls by pressing the user switch button.
These controls can regulate the temperature of devices
such as a hot tub or a radiant floor.
When a user switch button configured for setpoint controls
is pressed, the setpoint control changes the operational
setpoint from the unoccupied to the occupied temperature.
The setpoint control has a timer setting that counts down,
and when the timer expires, the setpoint device changes
back to the unoccupied temperature. Also, if the user switch
button is pressed a 2nd time, the setpoint device operation
changes back to the unoccupied temperature.
Setpoint
Control
User
Button
1
User
Button
2
User
Button
3
UnOcc
COLD
Press the “Hot Tub” button and the Hot Tub operates
for the set time.
Setpoint
Control
User
Button
1
User
Button
2
User
Button
3
Set Time
3:00 hr
HOT
Setpoint
Control
User
Button
1
User
Button
2
User
Button
3
Run Time
2:17hr
HOT
Press the “Hot Tub” button while the Setpoint Control is
running to disable the Hot Tub.
Setpoint
Control
User
Button
1
User
Button
2
User
Button
3
3 of 4 © 2006 U 481 - 06/06
UnOcc
COLD

Error Messages
If a single button begins to flash red, the user switch is
unable to communicate to a setpoint control. Contact your
installer to correct this condition.
If all 3 buttons begin to flash red together, the user switch
can no longer communicate to the rest of the tN4 controls.
Contact your installer to correct this condition.
Limited Warranty and Product Return Procedure
Limited Warranty The liability of tekmar under this warranty is lim-
ited. The Purchaser, by taking receipt of any tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at
the time of such Product sale and acknowledges that it has read
and understands same.
The tekmar Limited Warranty to the Purchaser on the Products sold
hereunder is a manufacturer’s pass-through warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in
workmanship and materials if the Product is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted.
The pass-through warranty period is for a period of twenty-four (24)
months from the production date if the Product is not installed during
that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production
date.
The liability of tekmar under the Limited Warranty shall be limited to, at
tekmar’s sole discretion: the cost of parts and labor provided by tekmar
to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the
defective product, and such repair, exchange or credit shall be the sole
remedy available from tekmar, and, without limiting the foregoing in any
way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages,
whether direct, indirect, special, secondary, incidental or consequential,
arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of
contract.
The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport
the defective Product, or to reinstall the repaired or replacement Product,
all such costs and expenses being subject to Purchaser’s agreement and
warranty with its customers.
Any representations or warranties about the Products made by Purchaser
to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser’s sole responsibility and obligation. Pur-
User
Button
1
User
Button
2
User
Button
3
User
Button
1
User
Button
2
User
Button
3
OR OR
User
Button
1
User
Button
2
User
Button
3
User
Button
1
User
Button
2
User
Button
3
chaser shall indemnify and hold tekmar harmless from and against any
and all claims, liabilities and damages of any kind or nature which arise
out of or are related to any such representations or warranties by Purchaser to its customers.
The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar,
accident, fire, Act of God, abuse or misuse; or has been damaged by
modifications, alterations or attachments made subsequent to purchase
which have not been authorized by tekmar; or if the Product was not
installed in compliance with tekmar’s instructions and / or the local codes
and ordinances; or if due to defective installation of the Product; or if the
Product was not used in compliance with tekmar’s instructions.
TH IS WARRANT Y IS I N LIEU OF A LL OTH ER WA RRA NTI ES, EXPRE SS
OR IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO
CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION,
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE, DURABILITY OR DESCRIPTION OF THE
PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS
OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY
LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY
CONTRACTUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL
NOT EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE
PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS
ALLOWED BY THE GOVERNING LAW.
Product Warranty Return Procedure All Products that are believed to
have defects in workmanship or materials must be returned, together
with a written description of the defect, to the tekmar Representative
assigned to the territory in which such Product is located. If tekmar
receives an inquiry from someone other than a tekmar Representative,
including an inquiry from Purchaser (if not a tekmar Representative) or
Purchaser’s customers, regarding a potential warranty claim, tekmar’s
sole obligation shall be to provide the address and other contact information regarding the appropriate Representative.
tekmar Control Systems Ltd., Canada
tekmar Control Systems, Inc., U.S.A.
Head Office: 5100 Silver Star Road
Vernon, B.C. Canada V1B 3K4
(250) 545-7749 Fax. (250) 545-0650
Web Site: www.tekmarcontrols.com
Product design, software and literature are Copyright © 2006 by:
tekmar Control Systems Ltd. and tekmar Control Systems, Inc.
4 of 4
All specifications are subject to change without notice.
Printed in Canada. U 481 - 06/06.