Introduction
The User Switch 480 has 3 programmable buttons that allow users to easily change the operating scene or allow users to
enable / disable tN4 setpoint devices on a tN4 system.
Multiple User Switches are required if more than 3 scenes or setpoint enable / disables are desired.
The 480 has 3 demand inputs that allow for connection of a tN4 system to a third party automation system or telephone
switch. This allows users to remotely change the operating scene on a tN4 system.
Features
• tN4 Compatible
• 3 User buttons
• 3 Demand Inputs
- Input for Home or Building Automation
- Input for Telephone Switch
- Input for Security Systems
User
Button
1
User
Button
2
User
Button
3
Decora cover plate not included
1 of 8 © 2009 D 480 - 09/09
Table of Contents
Table of Contents ............................................................2
User Interface .................................................................2
Sequence of Operation ...................................................3
3 User Buttons .......................................................3
Programming the User Buttons ..............................4
Demand Inputs ...............................................................6
Applications Using Multiple 480 & 481 Together ............7
Error Messages ..............................................................7
Cleaning the User Switch ..............................................8
Warranty .........................................................................8
User Interface
The User Switch has a total of 5 buttons.
User Buttons 1, 2, and 3 allow for users to select the operation of the tN4 system.
Buttons A and B allow the installer to program the operation of User Buttons 1, 2, and 3.
BUTTON
A
User
Button
1
User
Button
2
User
Button
3
BUTTON
B
Factory Defaults:
User Button 1
Scene = 1
Label = Normal
User Button 2
Scene = 3
Label = Unoccupied
User Button 3
Scene = 2
Label = Away
© 2009 D 480 - 09/09 2 of 8
Sequence of Operation
Three User Buttons
The User Switch provides users with a simple interface to
change the operating scene of the tN4 system or provide
an enable / disable to tN4 setpoint controls. The 480 has
3 User Buttons and 3 demand inputs.
The 3 User Buttons provide the ability to:
1) Select a scene for the tN4 system
The User Buttons allow users to select the scene of the
tN4 system. Each of the 3 User Buttons is programmed by
the installer to select a particular scene on the tN4 system.
The temperature of each tN4 thermostat in the system is
pre-programmed by the installer for each of the scenes.
This allows users to change the temperature of all the
thermostats using a single button.
tN4 thermostats and tN4 setpoint controls must have Scenes
turned to “On” in order to respond to scene changes on
the User Switch.
When a User Button is pressed, the green LED under that
button turns on and remains on until a new scene is selected,
or the time for the selected temporary scene expires.
When the current selected scene on the tN4 network is the
same as the scene that the User Button is programmed
for, the button turns green.
When a selected scene is “On” and that User button is pressed
again, the scene is changed based on the following table:
Current Scene
Perm Scene 1 No Change
Perm Scene 2
- Away
Perm Scene 3
- Unoccupied
Perm Scene 4 Selects Scene 1
Perm Scene 5
Press the
Same Button
New Scene
Selects Scene 1
Selects Scene 1
Selects Scene 1
Application Examples:
Allows residential users to change the scene to 2 (Away)
while going on vacation, or select an occupied scene
while entertaining guests.
Allows commercial users a simple way to allow staff to
override the night setback / setup schedule on the tN4
system.
2) Provide a setpoint device enable
Each of the 3 User Buttons can be programmed to enable
or disable one or more tN4 setpoint controls on the tN4 bus.
The installer programs a setpoint device enable number for
one of the User Buttons. In turn, the installer programs a
tN4 setpoint control with the same setpoint device enable
number. This allows users to enable or disable a tN4 setpoint
control by pressing a single button. Multiple tN4 setpoint
controls can be enabled or disabled from the same User
Switch button.
The tN4 setpoint control operates for the “Occupied Time”
or until the User Button is pressed once again to cancel the
operation. The User Button is green when the tN4 setpoint
device is in operation. Should the tN4 setpoint control be
unable to operate, the button turns red for 5 seconds and
then the button light is turned off.
See the tN4 Setpoint Control Data Brochure for more
information on the setpoint control operation.
Application Examples:
A user can remotely enable a tN4 setpoint control to heat
a hot tub or sauna.
A user can remotely enable a tN4 setpoint control to heat
a garage or workshop.
3) Disabled Button
The User Button can be disabled so that it does not function
when pressed.
Tmpy Scene 6
- Occupied
Tmpy Scene 7
Tmpy Scene 8
3 of 8 © 2009 D 480 - 09/09
Selects previous
perm scene
Selects previous
perm scene
Selects previous
perm scene