Sony SDX-D800V, SDX-D900V, SDX-D400V, SDX-D500V, SDX-D700V Operators Manual

...
0 (0)

2-176-211-06(1)

SDX-D1100V/D900V/D800V/D700V/D500V/D400V

AIT Drive Unit

Operator’s Guide –––––––––page 2–––––––––––––––38 Mode d’emploi –––––––––––page 78 Benutzerhandbuch –––––––Seite 112 Guía del operador ––––––––página 146

–––––––––––––––––180

––––––––––––––––––––––––––– 214

––––––––––––––––––––––––––– 246

Safety Regulations

Owner’s Record

The model and serial numbers are located on the bottom. Record the serial number in the space provided below.

Refer to them whenever you call upon your dealer regarding this product.

Model No.

Serial No.

________________________

__________________________________

Information

WARNING

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.

Model No. for Regulatory Compliance

Your SDX-D1100V is assigned a Model No.: SDX-D1100 for regulatory compliance certifications.Your SDX-D900V and SDX-D800V are assigned a Model No.:ATDEA4 for regulatory compliance certifications. Your SDX-D700V is assigned a Model No.: ATDEA3 for regulatory compliance certifications. Your SDX-D500V and SDX-D400V are assigned a Model No.: ATDEA2 for regulatory compliance certifications. The number is indicated on the model number label on your drive along with the rated voltage and current.

For the customers in the USA

You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

DECLARATION OF CONFORMITY

Trade Name:

SONY

 

Model:

SDX-D1100, ATDEA4, ATDEA3, ATDEA2

Responsible Party:

Sony Electronics Inc.

Address:

16530

Via Esprillo San Diego, CA.

 

92127

U.S.A.

Telephone number:

858-942-2230

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1)This device may not cause harmful interference.

(2)This device must accept any interference received, including

interference that may cause undesired operation.

2 Safety Regulations

WARNING

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.

CAUTION

The mains plug on this equipment must be used to disconnect mains power. Please ensure that the socket outlet is installed near the equipment and shall be easily accessible.

ACHTUNG

Zur Trennung vom Netz ist der Netzstecker aus der Steckdose zu ziehen, welche sich in der Nähe des Gerätes befinden muß und leicht zugänglich sein soll.

Hinweis

Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger gemäss EN ISO 7779.

NOTICE

Use the power cord set approved by the appropriate testing organization for the specific countries where this unit is to be used.

HINWEIS

Die 3-adrige Geräteanschlußleitung muß Typ H05VV-F oder H05VVH2-F sein und nach DIN VDE 0625 geprüft sein. Der Stecker und die Gerätesteckdose müssen nach DIN VDE 0620 bzw DIN VDE 0625 geprüft sein. Der Leitungsquerschnitt kann 0,5 mm2 betragen wenn die Anschlußleitung eine Länge von 2 m nicht überschreitet. Anderenfalls muß der Leitungsquerschnitt mindestens 0,75 mm2 betragen.

If you have any questions about this product, please refer to Sony contact in the instruction manual.

English

Safety Regulations

3

ATTENTION

According to the EU Directives related to product safety, EMC and R&TTE the manufacturer of this product is Sony Corporation, 1-7-1 Konan Minato-ku Tokyo, 108-0075 Japan. The Authorised Representative is Sony Deutschland GmbH, Hedelfinger Strasse 61,70327 Stuttgart, Germany. For any service or guarantee matters please refer to the addresses given in separate service or guarantee documents.

AUFMERKSAMKEIT

Im Sinne der EU Richtlinien bezüglich Produktsicherheit, EMV und R&TTE ist Sony Corporation, 1-7-1 Konan Minato-ku Tokyo, 108-0075 Japan der Hersteller dieses Produktes. Bevollmächtigter ist Sony Deutschland GmbH, Hedelfinger Strasse 61, D-70327 Stuttgart. Für Service oder Garantieangelegenheiten wenden Sie sich bitte an die in separaten Service oder Garantiedokumenten angegebenen Adressen.

European Union Restriction of Hazardous Substances Directive compliant.

Entspricht der Richtlinie der Europäischen Union zur Beschränkung der Verwendung gefährlicher Stoffe.

Für Kunden in Deutschland

Diese Ausrüstung erfüllt die Europäischen EMC-Bestimmungen für die Verwendung in folgender/folgenden Umgebung(en):

Wohngegenden

Gewerbegebiete

Leichtindustriegebiete

(Diese Ausrüstung erfüllt die Bestimmungen der Norm EN 55022, Klasse B.)

4 Safety Regulations

Sony SDX-D800V, SDX-D900V, SDX-D400V, SDX-D500V, SDX-D700V Operators Manual

IMPORTANT SAFEGUARDS

For your protection, please read these safety instructions completely before operating the appliance, and keep this manual for future reference.

Carefully observe all warnings, precautions and instructions on the appliance, or described in the operating instructions and adhere to them.

USE

Power Sources – This unit should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of electrical power, consult your dealer or local power company.

For the unit with a three-wire grounding type ac plug:

If you are unable to insert the plug into the outlet, contact your electrician to have a suitable plug installed. Do not defeat the safety purpose of the grounding plug.

AC Power cord:

The AC power cord should have appropriate safety approvals or marking for the country in which the equipment will be used. Consult your dealer or local power company.

Cleaning – Unplug the unit from the wall outlet before cleaning or polishing it. Do not use liquid cleaners or aerosol cleaners.

Use a cloth lightly dampened with water for cleaning the exterior of the unit.

Object and Liquid Entry – Never push objects of any kind into the unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit.

Safety Regulations

5

INSTALLATION

Water and Moisture – Do not use power-line operated units near water - for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool, etc.

Power-Cord Protection – Route the power cord so that it is not likely to be walked on or pinched by items placed upon or against it, paying particular attention to the plugs, receptacles, and the point where the cord exits from the appliance.

Accessories – Do not place the unit on an unstable cart, stand, tripod, bracket, or table. The unit may fall, causing serious injury to a child or an adult, and serious damage to the unit. Use only a cart, stand, tripod, bracket, or table recommended by the manufacturer.

Ventilation – The slots and openings in the cabinet are provided for necessary ventilation. To ensure reliable operation of the unit, and to protect it from overheating, these slots and openings must never be blocked or covered.

Never cover the slots and openings with a cloth or other materials.

Never block the slots and openings by placing the unit on a bed, sofa, rug, or other similar surface.

Never place the unit in a confined space, such as a bookcase, or built-in cabinet, unless proper ventilation is provided.

SERVICE

Damage Requiring Service – Unplug the unit from the wall outlet and refer servicing to qualified service personnel under the following conditions:

When the power cord or plug is damaged or frayed.

If liquid has been spilled or objects have fallen into the unit.

If the unit has been exposed to rain or water.

If the unit has been subject to excessive shock by being dropped, or the cabinet has been damaged.

If the unit does not operate normally when following the operating instructions. Adjust only those controls that are specified in the operating instructions. Improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the unit to normal operation.

When the unit exhibits a distinct change in performance - this indicates a need for service.

Servicing – Do not attempt to service the unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards.

Refer to all servicing to qualified service personnel.

6 Safety Regulations

Table of Contents

Part 1.

Introduction

Part 2.

Preparation

Part 3.

Operation

Part 4.

Care and

Maintenance

Appendix

How To Use This Guide .....................................................................

8

About AIT Drives ...............................................................................

9

Features ....................................................................................................

9

Compatible Data Cartridges ..................................................................

12

System Components ..............................................................................

13

Part Names and Functions .............................................................

14

Front Panel .............................................................................................

14

Rear Panel ..............................................................................................

15

Supplied Items.................................................................................

16

Interconnections .............................................................................

16

SCSI ID Setting ................................................................................

17

Option Switches (DIP Switch) ........................................................

17

How To Use the AIT Drive ...............................................................

22

Cartridge Removal .................................................................................

23

Attaching the Dust Cover ...............................................................

24

WORM Function ..............................................................................

26

Taking Care of the Drive .................................................................

28

Safety Considerations ............................................................................

28

Avoiding Damage ..................................................................................

28

Taking Care of Cartridges ..............................................................

30

Use Precautions .....................................................................................

30

Storage Precautions ...............................................................................

30

Cleaning ...........................................................................................

31

How To Clean ........................................................................................

31

Specifications (SDX-D1100V) .........................................................

32

Specifications (SDX-D900V) ...........................................................

33

Specifications (SDX-D800V) ...........................................................

34

Specifications (SDX-D700V) ...........................................................

35

Specifications (SDX-D500V) ...........................................................

36

Specifications (SDX-D400V) ...........................................................

37

 

Table of Contents

7

 

How To Use This Guide

This Guide describes the SDX-D1100V/SDX-D900V/SDX-D800V/ SDX-D700V/SDX-D500V/SDX-D400V drive, and how to take care of it. Please read it carefully before using the unit, and keep it handy for future reference.

The Guide consists of four parts, plus the specifications. Refer to the parts that relate to your use of the drive.

Part 1 describes the features of the drive, its system components, and the name and function of each part.

Part 2 describes the necessary connections between the drive and the host computer. If other SCSI devices are being used, you may need to change the SCSI ID setting. Read this part if you are installing the drive.

Part 3 describes how to use the drive, including how to turn it on, and how to insert and remove cartridges. Read this part if you are going to operate the drive.

Part 4 describes how to take care of the drive and cartridges, and how to clean the drive. Read this part before using the drive.

Appendix provides the major specifications of the SDX-D1100V/

SDX-D900V/SDX-D800V/SDX-D700V/SDX-D500V/SDX-D400V drive.

8 How to Use this Guide

Part 1. Introduction

About AIT Drives

The SDX-D1100V AIT-5 Tape Drives is an external AIT drive unit that uses data cartridges conforming to the AIT-5 format.

The SDX-D900V AIT-4 Tape Drive is an external AIT drive unit that uses data cartridges conforming to the AIT-4 format.

The SDX-D800V AIT-3 Ex Tape Drives is an external AIT drive unit that uses data cartridges conforming to the AIT-3 Ex format.

The SDX-D700V AIT-3 Tape Drive is an external AIT drive unit that uses data cartridges conforming to the AIT-3 format.

The SDX-D500V AIT-2 Tape Drive is an external AIT drive unit that uses data cartridges conforming to the AIT-2 format.

The SDX-D400V AIT-1 Tape Drive is an external AIT drive unit that uses data cartridges conforming to the AIT-1 format.

The SDX-D1100V drive supports the AIT-5, AIT-4, AIT-3 Ex, and AIT-3 formats.

The SDX-D900V drive supports the AIT-4 and AIT-3 Ex format.

The SDX-D800V drive supports the AIT-3 Ex, AIT-3, AIT-2 Turbo, AIT-2 (Read only), AIT-1 Turbo (Read only), AIT-1 (Read only), and AIT-E Turbo (Read only) formats.

The SDX-D700V drive supports the AIT-3, AIT-2, and AIT-1 formats. The SDX-D500V drive supports the AIT-2 and AIT-1 formats.

The SDX-D400V drive supports only the AIT-1 format.

Features

The SDX-D1100V drive has the following features:

Supports reading and writing to data cartridges conforming to the AIT-5, AIT-4, AIT-3 Ex, and AIT-3 formats.

The second-level error correction code guarantees high data reliability writing to data cartridges conforming to the AIT-5, AIT-4, and AIT-3 Ex formats.

The third-level error correction code guarantees high data reliability writing to data cartridges conforming to the AIT-3 format.

Data compression provides 1,040 gigabytes of storage on SDX5-400C data cartridges.*

The native capacity is 400 gigabytes of storage on SDX5-400C data cartridges.

Stored data are automatically checked for compression.

Ultra 160 SCSI interface is fully supported for host computer access.

Fragment rewrite function (AIT-5, AIT-4, AIT-3 Ex)

Frame rewrite function (AIT-3)

*This is assuming 2.6:1 compression ratio.

The degree of data compression attained while recording data varies according to system environment and data type.

Part 1. Introduction

9

The SDX-D900V drive has the following features:

Supports reading and writing to data cartridges conforming to the AIT-4 and AIT-3 Ex formats.

The second-level error correction code guarantees high data reliability writing to data cartridges conforming to the AIT-4 and AIT-3 Ex formats.

Data compression provides 520 gigabytes of storage on SDX4-200C data cartridges.*

The native capacity is 200 gigabytes of storage on SDX4-200C data cartridges.

Stored data are automatically checked for compression.

Ultra 160 SCSI interface is fully supported for host computer access.

Fragment rewrite function

The SDX-D800V drive has the following features:

Supports reading and writing to data cartridges conforming to the AIT-3 Ex, AIT-3, and AIT-2 Turbo formats.

Supports reading from data cartridges conforming to the AIT-2, AIT-1 Turbo, AIT-1, and AIT-E Turbo formats.

The second-level error correction code guarantees high data reliability writing to data cartridges conforming to the AIT-3 Ex format.

The third-level error correction code guarantees high data reliability writing to data cartridges conforming to the AIT-3 format.

Data compression provides 390 gigabytes of storage on SDX3X-150C data cartridges.*

The native capacity is 150 gigabytes of storage on SDX3X-150C data cartridges.

Stored data are automatically checked for compression.

Ultra 160 SCSI interface is fully supported for host computer access.

Fragment rewrite function (AIT-3 Ex)

Frame rewrite function (AIT-3)

The SDX-D700V drive has the following features:

Supports reading and writing to data cartridges conforming to the AIT-3, AIT-2, and AIT-1 formats.

The third-level error correction code guarantees high data reliability.

Data compression provides 260 gigabytes of storage on SDX3-100C data cartridges.*

The native capacity is 100 gigabytes of storage on SDX3-100C data cartridges.

Stored data are automatically checked for compression.

Ultra 160 SCSI interface is fully supported for host computer access.

Frame rewrite function

*This is assuming 2.6:1 compression ratio.

The degree of data compression attained while recording data varies according to system environment and data type.

10 Part 1. Introduction

The SDX-D500V drive has the following features:

Supports reading and writing to data cartridges conforming to the AIT-2 and AIT-1 formats.

The third-level error correction code guarantees high data reliability.

Data compression provides 130 gigabytes of storage on SDX2-50C data cartridges.*

The native capacity is 50 gigabytes of storage on SDX2-50C data cartridges.

Stored data are automatically checked for compression.

Wide Ultra SCSI (LVD/SE) interface is fully supported for host computer access.

Frame rewrite function

The SDX-D400V drive has the following features:

Supports reading and writing to data cartridges conforming to the AIT-1 format.

The third-level error correction code guarantees high data reliability.

Data compression provides 91 gigabytes of storage on SDX1-35C data cartridges.*

The native capacity is 35 gigabytes of storage on SDX1-35C data cartridges.

Stored data are automatically checked for compression.

Wide Ultra SCSI (LVD/SE) interface is fully supported for host computer access.

Frame rewrite function

*This is assuming 2.6:1 compression ratio.

The degree of data compression attained while recording data varies according to system environment and data type.

Part 1. Introduction 11

Compatible Data Cartridges

The SDX-D1100V drive can be used with data cartridges marked with the

AIT-5, AIT-4, AIT-3 Ex, or AIT-3 logo.

The SDX-D900V drive can be used with data cartridges marked with the

AIT-4 or AIT-3 Ex logo.

The SDX-D800V drives can be used with data cartridges marked with the

AIT-3 Ex, AIT-3, AIT-2 Turbo, AIT-2 (read only), AIT-1 Turbo (read only),

AIT-1 (read only), or AIT-E Turbo (read only) logo.

The SDX-D700V drive can be used with data cartridges marked with the

AIT-3, AIT-2, or AIT-1 logo.

The SDX-D500V drive can be used with data cartridges marked with the

AIT-2 or AIT-1 logo.

The SDX-D400V drive can be used with data cartridges marked with the

AIT-1 logo.

AIT-E Turbo LOGO

AIT-1 LOGO

AIT-1 Turbo LOGO

AIT-2 LOGO

AIT-2 Turbo LOGO

AIT-3 LOGO

AIT-3 Ex LOGO

AIT-4 LOGO

AIT-5 LOGO

Caution

Do not use cartridges other than the ones described above with this drive. Be sure to use only the cartridges designed specifically for AIT.

Do not use anything but AIT cartridges with this drive, as doing so can damage the drive. Although commercially available 8 mm videotapes resemble AIT cartridges in appearance, they have entirely different specifications and cannot be used.

12 Part 1. Introduction

System Components

This drive uses a wide SCSI interface. The following shows a typical system configuration.

Host Computer

Wide SCSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SDX-D1100V

 

 

 

Peripheral Devices

Terminator

SDX-D900V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SDX-D800V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SDX-D700V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SDX-D500V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SDX-D400V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example connection to the host computer and other peripheral devices

Part 1. Introduction 13

Part Names and Functions

Front Panel

1 2

 

Advanced

 

 

 

Intelligent

 

 

 

Tape

 

 

3

4

5

6

1AIT Data Cartridge Receptacle

See page 22 to 23 for information on inserting and removing a AIT data cartridge.

2POWER Indicator

Lights while the drive is on.

3Dust Cover

Prevents dust from entering the data cartridge receptacle. Keep this cover closed when not inserting or removing data cartridges.

4LED Indication for Drive Status

The LED indicators are defined as follows.

 

 

 

 

 

 

 

 

 

 

 

LED

 

 

 

 

 

 

 

TAPE

 

 

CLEANING

REPLACE

Sense

MOTION

 

 

REQUEST

 

TAPE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Independent

Independent

Tape Loaded

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Independent

Independent

Tape Access in Progress

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(write/read)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Independent

Independent

Tape Access in Progress (others)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Independent

 

 

 

 

 

 

 

 

 

Independent

Cleaning is requested

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Independent

 

 

 

 

 

 

 

 

 

Independent

Cleaning is Not Completed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Independent

 

 

Independent

 

 

 

 

 

Media Error Occurred

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H/W Error Occurred

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 pulse (0.9 sec on/0.3 sec off)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 pulse (0.3 sec on/0.3 sec off)

 

14 Part 1. Introduction

5EJECT Button

Push to remove a data cartridge from the drive.

6POWER Switch

Press to turn the drive on or off.

Rear Panel

1

2 3 4

1Rotary Selector Switch

SCSI ID selector.

2AC IN Connector

Connect the supplied power cable here.

3SCSI Connector

Connects to the SCSI interface of the host computer or peripheral device via a Wide SCSI cable.

4 Cooling Fan

Part 1. Introduction 15

Part 2. Preparation

After you confirm that you have all of the required accessories for your installation, connect the drive to the host computer, and select the SCSI ID with the rotary switch on the rear panel.

Supplied Items

When you first open the box, make sure it contains the following items.

Contact your supplier if anything is missing or broken.

AIT Drive Unit

Power Cable

Operator’s Guide

Interconnections

A single Wide SCSI bus allows connection of up to 15 peripheral SCSI devices.

Use a commercially available SCSI cable appropriate to the peripheral device for connections.

This drive uses a 68-pin half-pitch connector.

Precautions

Switch off the host computer and peripherals before connecting the SCSI cable.

Make sure the SCSI connectors are pressed tightly together.

If this unit is the last (or only) device on the SCSI bus, make sure to connect a terminator to the appropriate unused SCSI connector. Using an incompatible terminator may damage the unit.

During LVD SCSI connections, make sure that the total length of the cable(s) connecting the host computer and the last device on the SCSI bus is no longer than 12 meters (39 feet). (During single-end SCSI connections, make sure that the total length of the SCSI cable(s) is no longer than 1.5 meters (5 feet).)

Terminator

AC power

16 Part 2. Preparation

SCSI ID Setting

The SCSI ID is set by the rotary switch on the rear panel. Press the + or - buttons to move the number up or down, respectively.

As shipped from the factory, the SCSI ID is set to 0. Press the switch buttons, if necessary, to select the SCSI ID number you require. Because the host adapter ID is usually set to 7, select some other value for the SCSI ID setting.

Precautions

The SCSI ID must be different from the IDs of the other peripherals on the SCSI bus.

When shipped from the factory, SCSI parity is enabled and Term power is ON. Be sure to connect a terminator to the SCSI bus before use.

Before changing the SCSI ID setting, be sure to turn off the power with the POWER switch on the front panel.

Option Switches (DIP Switch)

Remove the two slotted screws by using a slotted screwdriver. Remove the access cover to change the DIP switch settings. (Refer to the following figure for details changing the DIP switch settings.)

After changing the DIP switch settings, replace access cover and tighten the two slotted screws using a slotted screwdriver.

CAUTION

Before removing the access cover to change DIP switch settings on the drive, turn off the computer and disconnect the power cord from the unit. Once the DIP switch settings have been changed, replace the access cover using the two original slotted screws provided.

Access Cover

Slotted

Screws

DIP Switch

Part 2. Preparation 17

DIP Switch Positions

(for the SDX-D1100V, SDX-D900V, and SDX-D800V Drives)

Default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

DR (Disaster Recovery) Mode (OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Emulation Mode (OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

AIT Library Interface Mode (ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Reserved (OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Terminator Power (ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8

 

 

6

Periodic Cleaning Req (ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

DC Control (1)

(ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

DC Control (2)

(OFF)

Emulation Mode*

To enable Emulation Mode, set DIP switch 2 [Emulation Mode] to ON.

ON

OFF

1 2 3 4 5 6 7 8

*Emulation Mode for the SDX-D1100V drive returns the following as the Product Identification field of the Inquiry command.

SDX-900V

*Emulation Mode for the SDX-D900V drive returns the following as the Product Identification field of the Inquiry command.

SDX-700C

*Emulation Mode for the SDX-D800V drive returns the following as the Product Identification field of the Inquiry command.

SDX-700C

Terminator Power

To enable terminator power, set DIP switch 5 [Terminator Power] to ON.

ON

OFF

1 2 3 4 5 6 7 8

18 Part 2. Preparation

Periodic Cleaning Request Mode

To enable Periodic Cleaning Request Mode, set DIP switch 6 [Periodic Cleaning Req] to ON.

ON

OFF

1 2 3 4 5 6 7 8

The “CLEANING REQUEST” LED on the front panel lights after every 100 hours of operation.

When this LED lights, clean the drive with a cleaning cartridge.

Note

To maintain the drive in optimum condition in environments affected by dust and other contaminants, we recommend keeping cleaning requests enabled.

Data Compression Control

Data compression can be selected by DIP switches.

Data compression is enabled when DIP switch 7 [DC Control (1)] is ON.

ON

OFF

1 2 3 4 5 6 7 8

Control by host can be disabled when DIP switch 8 [DC Control (2)] is ON.

ON

OFF

1 2 3 4 5 6 7 8

Part 2. Preparation 19

DIP Switch Positions

(for the SDX-D700V, SDX-D500V, and SDX-D400V Drives)

Default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Drive Mode (OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Drive Mode (OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Drive Mode (OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Drive Mode (OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Terminator Power (ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8

 

 

6

Periodic Cleaning Req (ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

DC Control (1)

(ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

DC Control (2)

(OFF)

Emulation Mode*

To enable Emulation Mode, set DIP switches 1 to 4 [Drive Mode] to ON.

ON

OFF

1 2 3 4 5 6 7 8

*Emulation Mode for the SDX-D700V drive returns the following as the Product Identification field of the Inquiry command.

SDX-700C

*Emulation Mode for the SDX-D500V drive returns the following as the Product Identification field of the Inquiry command.

SDX-500C

*Emulation Mode for the SDX-D400V drive returns the following as the Product Identification field of the Inquiry command.

SDX-400C

Terminator Power

To enable terminator power, set DIP switch 5 [Terminator Power] to ON.

ON

OFF

1 2 3 4 5 6 7 8

20 Part 2. Preparation

Periodic Cleaning Request Mode

To enable Periodic Cleaning Request Mode, set DIP switch 6 [Periodic Cleaning Req] to ON.

ON

OFF

1 2 3 4 5 6 7 8

The “CLEANING REQUEST” LED on the front panel lights after every 100 hours of operation.

When this LED lights, clean the drive with a cleaning cartridge.

Note

To maintain the drive in optimum condition in environments affected by dust and other contaminants, we recommend keeping cleaning requests enabled.

Data Compression Control

Data compression can be selected by DIP switches.

Data compression is enabled when DIP switch 7 [DC Control (1)] is ON.

ON

OFF

1 2 3 4 5 6 7 8

Control by host can be disabled when DIP switch 8 [DC Control (2)] is ON.

ON

OFF

1 2 3 4 5 6 7 8

Part 2. Preparation 21

Part 3. Operation

This section describes how to use the AIT drive, and how to handle data cartridges.

How To Use the AIT Drive

1Press the POWER switch on the front panel.

The POWER indicator should light, and the TAPE MOTION, CLEANING REQUEST, and REPLACE TAPE indicators should blink as the self-test is performed.

2When the three indicators stop blinking, open the dust cover and insert a data cartridge as shown below. The TAPE MOTION indicator lights.

3Computer software controls the reading and writing of tapes. While reading or writing, the TAPE MOTION indicator blinks.

4Close the dust cover.

22 Part 3. Operation

Cartridge Removal

1Press the EJECT button.

2Open the dust cover.

The cartridge is ejected automatically.

Caution

Do not push the EJECT button while the TAPE MOTION indicator is blinking. To do so may destroy data on the tape.

3 Remove the cartridge from the receptacle, and then close the dust cover.

Part 3. Operation 23

Attaching the Dust Cover

If the dust cover comes loose, attach it as described below.

Note

We recommend that you use the drive with the dust cover.

1Align the dust cover’s hinge clips (one on each side) with the pins of the drive bezel.

The dust cover should be positioned so that the magnets* on the cover’s back face the drive bezel.

*This magnet does not affect the tape of the cartridge.

Holding the dust cover at an angle as shown in the figure below, set the hinge clips on top of the bezel pins, positioning them so that they bracket the pins.

Magnet

Bezel pin

Hinge clip

24 Part 3. Operation

2Press down at an angle on each side in turn until you hear the hinge clips click into place.

Caution

Do not press the dust cover in horizontally from the front. Doing so could cause the dust cover to break.

3Close the dust cover.

This completes attachment of the dust cover.

Part 3. Operation 25

WORM Function

The SDX-D1100V, SDX-D900V, SDX-D700V, and SDX-D500V drives support the WORM function. This explains the WORM function.

What is “WORM”?

“WORM” is an acronym for “Write Once Read Many”, a function that allows data to be written to the same place on a tape only once, but permits that data to be read from the tape for any number of times. The SDX-D1100V, SDX-D900V, SDX-D700V, and SDX-D500V drives support WORM cartridges. When a WORM cartridge is used with an application that supports the WORM function, data that has been written to a tape can not be accidentally deleted or overwritten.

A WORM drive operates in the same manner as a non-WORM drive when used with a non-WORM cartridge (henceforth referred to as “regular cartridge”).

The operation of a WORM drive and a non-WORM drive differs according to the type of cartridge that is being used.

Tape Drive

 

Cartridge

 

 

 

 

 

Regular Cartridge

 

WORM Cartridge

 

(without WORM logo)

(with WORM logo)

 

 

 

 

Non-WORM drive

Read/Write Enabled

 

Waiting for Eject

WORM drive

Read/Write Enabled

 

Read/

 

 

 

Append-Write Enabled

 

 

 

 

WORM Cartridges

WORM cartridges can be distinguished from regular cartridges by their

WORM logo and red shutters.

Red

WORM logo

AIT-5 WORM cartridge: SDX5-400W

AIT-4 WORM cartridge: SDX4-200W

AIT-3 WORM cartridge: SDX3-100W

AIT-2 WORM cartridge: SDX2-50W

26 Part 3. Operation

How to Write Data onto a WORM Cartridge

As with a regular cartridge, there is no limit on how many times data can be read from a WORM cartridge. When writing data to a WORM cartridge, the data cannot be written to a portion of the tape that data has already been written.

When writing data onto a WORM cartridge, it is appended after data that has already been written onto the cartridge. Accordingly, move to the EOD area before writing data onto the cartridge.

SCSI Commands Supported by the WORM Drive

The WORM drives support the same SCSI commands that are supported by non-WORM drives. However, if an attempt is made to write to a portion of a tape where data has already been written, the following error information is returned: “Sense Key = 07, ASC = 27h, ASCQ = 00: Persistent Write Protect” or “Sense Key = 03, ASC = 27h, ASCQ = 04: Write Position Error.”

Notes

The manufacturer does not accept liability for data written onto a WORM cartridge that is lost as a result of using this unit.

The manufacturer accepts no responsibility for any financial damages, lost profits, or claims made by third parties arising from the use of this product.

Part 3. Operation 27

Part 4. Care and Maintenance

Taking Care of the Drive

Safety Considerations

Power

Be sure to use only 100 V - 240 V AC.

Avoid plugging into the same outlet as high-current equipment like copiers or shredders.

Power Cable Precautions

Do not crush the cable or place heavy items on it. If the cable insulation appears worn or broken, do not use the cable.

Always unplug the cable by holding the plug. Never pull the cable itself, as it will break.

If the drive is not being used for a long time, unplug the cable from the outlet.

Avoiding Damage

Avoid shock and vibration

Intense shock, such as from dropping the drive, will damage it.

Environmental considerations

Do not store or use the drive in locations subject to:

high humidity

excessive dust

high temperature

intense vibration

direct sunlight

sudden changes in temperature

Proper ventilation

To avoid overheating, install the drive where it will have free air circulation around the case, and do not cover it during operation. The drive can malfunction if the internal temperature rises too high.

28 Part 4. Care and Maintenance

Avoid sudden changes in temperature

If the drive is moved from a cool place to a warm place, or if the room temperature suddenly rises, moisture may condense inside the case. After a sudden change in temperature, wait at least one hour before turning the drive on.

Inserting a cartridge with condensation inside the drive can damage the drive or the tape. Immediately remove cartridges in the drive if there is a possibility that there is condensation inside.

Leaving the drive on without inserting cartridges, moreover, will quickly evaporate any condensation.

Abnormal occurrences

If the drive behaves abnormally, or if it begins to smell or smoke, immediately unplug it from the wall outlet and contact your supplier for assistance.

Cabinet cleaning

Wipe the cabinet with a soft dry cloth. For heavy dirt, wipe with a soft cloth moistened with a gentle liquid soap, then wipe again with a soft dry cloth. Do not use alcohol, paint thinner, bug sprays, or other volatile solvents, as they can damage the finish.

Part 4. Care and Maintenance 29

Taking Care of Cartridges

Use Precautions

Avoid heavy vibration and dropping.

The shutter on the face of the cartridge is opened automatically when it is inserted into the drive. Do not open the shutter by hand, as touching the tape may damage it.

The cartridge was carefully aligned during assembly at the factory. Please do not try to open it or take it apart.

The write-protect switch on the face of the cartridge prevents the tape from being written to or accidentally erased. If you do not need to write to the tape, move this switch to the write-protect position (in the direction of the arrow).

AIT-5

AIT-4

AIT-3 Ex

AIT-3

AIT-2 Turbo

AIT-2

AIT-1 AIT-1 Turbo

AIT-E Turbo

Using your fingernail, push the switch in the direction of the arrow to protect the tape from writing or accidental erasure.

Return the switch to its original position to re-enable writing.

In case of a sudden change in temperature, condensation may interfere with reading and writing to a tape.

Avoid unnecessary insertion and removal of cartridges if you do not need to write or read a tape.

When finished using the drive, remove the cartridge.

Storage Precautions

Keep cartridges in their cases when not in the drive.

Avoid storing cartridges in dusty places, in direct sunlight, near heaters or air conditioners, or, in humid locations.

Do not place cartridges on the dashboard or in a storage tray in a car.

30 Part 4. Care and Maintenance