Sony HDC-3100 User Manual

4.3 (4)

4-745-633-11 (1)

Fiber Color Camera

HDC3100

Triax Color Camera

HDC3170

Operating Instructions

Before operating the unit, please read this manual thoroughly and retain it for future reference.

© 2018 Sony Corporation

Table of Contents

 

Overview.....................................................................

3

Supported Formats ..........................................................

3

System Configuration.......................................................

4

Locations and Functions of Parts............................

6

Accessory Attachments....................................................

6

Controls and Connectors .................................................

7

Preparations.............................................................

11

Attaching a Lens ............................................................

11

Adjusting the Flange Focal Length.................................

11

Attaching a Viewfinder ...................................................

11

Attaching the Cable Clamp Belt (Supplied)....................

12

Adjusting the Shoulder Pad Position..............................

13

Mounting the Camera to a Tripod ..................................

13

Adjustments and Settings for Shooting................

14

Adjusting the Black Balance and White Balance ...........

14

Setting the Electronic Shutter.........................................

16

Setting the Focus Assist Functions ................................

16

Setting the Focus Position Meter Function ....................

18

Setting the Camera Outputs ...................................

19

Viewfinder Screen Status Display..........................

20

Menu Operations .....................................................

21

Starting Menu Operations ..............................................

21

Selecting Pages .............................................................

22

Setting the Menu Items ..................................................

23

Editing the USER Menu .................................................

23

Menu List..................................................................

27

Menu Tree......................................................................

27

OPERATION Menu ........................................................

32

PAINT Menu...................................................................

40

MAINTENANCE Menu ...................................................

43

FILE Menu......................................................................

46

DIAGNOSIS Menu .........................................................

48

Appendix ..................................................................

50

Precautions ....................................................................

50

Digital Triax Transmission (HDC3170)...........................

50

Error Messages..............................................................

51

Using a USB Drive ...................................................

52

Specifications ..........................................................

53

HDC3100/3170 ..............................................................

53

Optional Accessories/Related Equipment......................

53

Dimensions ....................................................................

55

2

Overview

The HDC3100/3170 are color cameras equipped with a newly developed 2/3 inch CMOS sensor with global shutter for F12 (1080/ 59.94i)/F13 (1080/50i) high sensitivity and 62 dB high signal-to-noise ratio.

The HDC3100 supports operation as a studio camera when connected with an HDCU3100 a), HDCU3170 b), or HDCU2000-series c) Camera Control Unit (CCU) using a fiber cable.

The HDC3170 supports operation as a studio camera when connected with an HDCU3170 using a triax cable.

a)Use HDCU3100 software version 2.00 or later.

b)Install the HKCU-FB30 Optical Fiber Connector Kit (option).

c)Use HDCU2000-series software version 3.30 or later.

Note

Before starting system operation, check that the software version and ROM version of the unit and system devices meet the version requirements.

Supported Formats

The unit supports 1080-59.94i, 1080-50i, 720-59.94P, and 720-50P formats as standard. (The HDC3170 supports 1080-59.94P and 1080-50P formats as standard.)

You can extend the formats that are supported by installing the following camera operating software (option).

For details, contact a Sony service or sales representative.

Camera operating software

Extended formats

 

 

HZC-PRV50/PRV50M/PRV50W 1080-59.94P 1080-50P

HZC-PSF50/PSF50M/PSF50W 1080-24PsF 1080-23.98PsF 1080-25PsF 1080-29.97PsF

Notes

HZC-PRV50M/PSF50M are 30-day software licenses.

HZC-PRV50W/PSF50W are 7-day software licenses.

HZC-PSF50/PSF50M/PSF50W cannot be installed on the HDC3170.

3

System Configuration

Note

Production of some of the peripherals and related devices shown in the figures has been discontinued. For advice on choosing devices, please contact your Sony dealer or a Sony sales representative.

Connection example (optical fiber transmission)

 

HDVF-EL75/L750/L770

 

Viewfinder

 

 

HDVF-EL20

 

HDVF-EL30

 

Viewfinder

Lens

HDC3100

 

(for ENG/EFP)

Optical fiber cable a)

 

 

USB drive

VCT-14 Tripod

CAC-6

 

Return Video Selector

Attachment

 

 

 

Intercom headset

Tripod

CAC-12

Microphone

 

Microphone

 

Holder

 

a)Signal transfer up to a maximum of 2 km is possible. However, the actual transfer distance may vary depending on the system configuration of the cameras and the type of optical fiber cables used.

b)Set the signal transmission rate for the camera to connect using the following menu item on the camera control unit.

SYSTEM CONFIG t <CAMERA I/F> t FIBER TRANSMIT RATE

For details, refer to the operation manual of the camera control unit.

c)To use the HDCU3170, install the HKCU-FB30 Optical Fiber Connector Kit.

Sync signal input

 

 

 

 

 

Return video input

2K video

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

monitor

 

 

 

 

Intercom

 

 

 

 

microphone

 

 

 

 

 

 

 

input

 

 

CCA-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCP-1500/1000 series

 

 

Remote Control Panel

LANcable

HDCU3100, HDCU3170 c)

monitor

monitor

BNC

 

Camera Control Unit b)

 

 

 

 

Video

Waveform

 

Hub

 

 

 

LAN cable

 

 

 

 

Video router

MSU-1000 series

Master Setup Unit

HKCU1001/1003/ CCA-5 2007/2040

 

 

 

RCP-1500/1000 series

 

 

 

Remote Control Panel

 

HDCU2000

 

 

 

 

Camera Control Unit

 

 

 

cable

HKCU1001/1003/

BNC

Video

Waveform

2007/2040

monitor

monitor

 

 

LAN

CCA-5

 

 

 

 

 

 

 

HDCU2500

Camera Control Unit

Hub

LAN cable

Video router

RCP-1500/1000 series

Remote Control Panel

MSU-1000 series Master Setup Unit

4

Connection example (digital triax)

 

HDVF-EL75/L750/L770

 

Viewfinder

 

HDVF-EL20

 

HDVF-EL30

 

Viewfinder

Lens

HDC3170

(for ENG/EFP)

Triax cable a)

 

 

USB drive

VCT-14 Tripod

CAC-6

Return Video Selector

Attachment

 

 

Intercom headset

Tripod

CAC-12

 

Microphone Microphone

 

Holder

Sync signal input

 

 

 

 

Return video input

 

 

 

 

Intercom

2K video

 

 

 

monitor

 

 

 

microphone

 

 

 

 

 

 

 

input

 

CCA-5

 

 

 

 

 

 

 

 

RCP-1500/1000 series

 

 

 

Remote Control Panel

cableLAN

HDCU3170 b)

BNC

 

 

Camera Control Unit

 

 

 

 

 

 

 

 

 

Video

Waveform

 

Hub

 

monitor

monitor

 

 

 

 

 

LAN cable

 

Video router

 

 

 

MSU-1000 series

Master Setup Unit

a)Signal transfer up to a maximum of 1.8 km is possible. However, the actual transfer distance may vary depending on the system configuration of the cameras and the type of triax cables used.

For details, see page 50.

b)Set the signal protocol using the following menu item on the camera control unit. SYSTEM CONFIG t <CAMERA I/F> t TRIAX TRANSMIT

For details, refer to the operation manual of the camera control unit.

5

Locations and Functions of Parts

Accessory Attachments

O

 

A

 

 

B

 

 

C

 

 

D

 

 

E

 

 

F

 

 

G

 

 

H

N

 

I

M

 

 

L

J

 

 

 

 

K

a VF (viewfinder) connector (20-pin)

Connect the cable of the viewfinder (not supplied).

b Shoulder strap fitting post

Attach one end of a shoulder strap (not supplied) to this fitting post, and the other end to the fitting post on the other side of the camera.

c Accessory shoe

To attach an accessory using a 1/4-inch screw.

d Viewfinder left-right positioning ring

Loosen this ring to adjust the viewfinder position towards the left or right.

e Viewfinder front-rear positioning lever

Unlock the front-rear positioning lever to adjust the viewfinder position towards the front or rear, then lock in the desired position.

For details on adjusting the viewfinder position, see “Attaching a Viewfinder” on page 11.

f Lens cable clamp

To secure the cable of the lens (not supplied).

g Lens fixing lever

To secure the lens in the lens mount.

h Lens mount cap

The cover can be removed by moving the lens fixing lever upwards. Always keep the lens mount covered with this cap when a lens is not attached.

i Lens mount

To attach a lens.

j LENS connector (12-pin)

Connect the lens cable. The camera can control the lens functions through this cable.

k Tripod mount

Attach the VCT-14 Tripod Attachment when mounting the camera on a tripod.

l Camera number

Insert the supplied camera number label to display the camera number.

m Shoulder pad

You can adjust the position so that you can get the best balance for shooting with the camera on your shoulder.

For details, see “Adjusting the Shoulder Pad Position” on page 13.

n Microphone holder attachment

Use to attach a CAC-12 Microphone Holder.

For details, refer to the microphone holder operation manual.

o V-wedge shoe attachment points

Attach a V-wedge shoe here to mount an HDVF-EL75/L750/ L770 Viewfinder.

Note

Select either the front or rear V-wedge shoe attachment points to attach the V-wedge shoe. If the front position is used, it may restrict the tilt/pan angle available for the viewfinder.

For details about attachment, refer to the operation manual of the viewfinder.

6

Controls and Connectors

Front right

a

 

b

 

c

 

d

f

 

 

g

 

h

e

i

j

 

 

k

a INCOM1 (intercom 1) button

The intercom 1 microphone is turned ON while this button is held pressed.

You can also assign other functions to this button, using the menu displayed on the viewfinder screen.

b RET 1 (return video 1) button

The return video 1 signal from the camera control unit is monitored on the viewfinder screen while this button is pressed. It function the same as the RET 1 button on the side (page 8) and RET/ASSIGNABLE button A on the operation panel on the rear of the camera (page 9).

You can also assign other functions to this button, using the menu displayed on the viewfinder screen.

c ASSIGN (assignable) A, B, C, D switches

You can assign a function using the menu displayed on the viewfinder screen.

You can also display the assigned function name by attaching the corresponding label (supplied) for the assigned function.

d Filter select control

Turn the knob to select the internal filter setting.

e AUTO W/B BAL (white and black balance automatic adjustment) switch

To automatically adjust white and black balance when the camera is used in standalone status without connecting to the camera control unit.

WHT: Automatically adjust white balance. BLK: Automatically adjust black balance.

f GAIN switch

To select the gain of the video amplifier based on lighting conditions when the camera is used in standalone status without connecting a camera control unit.

When shipped from the factory, the values set are L = 0 dB, M = 6 dB, and H = 12 dB.

g OUTPUT (output signal selection)/AUTO KNEE switch

To select the signal (color bar signal or camera’s video signal) to be used as output to the viewfinder or a video monitor when the camera is used in standalone status without connecting a camera control unit.

When the camera’s video signal is being used as output, the auto knee function may be used.

The relationship between the switch setting and the output signal and auto knee function is shown in the table below.

OUTPUT

AUTO KNEE

Function

BARS

OFF

Output is a color bar signal.

 

 

 

CAM

OFF

Output is the camera’s video signal.

 

 

The auto knee circuit is disabled.

 

 

 

CAM

ON

Output is the camera’s video signal.

 

 

The auto knee circuit is enabled.

 

 

 

h WHITE BAL (white balance memory selection) switch

To select the white balance adjustment method or the memory used to store the adjusted value when the camera is used in standalone status without connecting a camera control unit.

PRST (preset): White balance is adjusted to a preset value corresponding to a color temperature of 3200K.

A or B: Selects memory A or B.

i DISPLAY switch

The functions of the DISPLAY switch are as follows: DISPLAY: Characters and messages showing the camera

settings and operating status may be displayed on the viewfinder screen.

OFF: Status messages will not appear on the viewfinder screen.

MENU: Menus for camera settings will be displayed on the viewfinder screen.

j STATUS/CANCEL switch

STATUS: When no menu is displayed on the viewfinder screen, the status information of this camera is displayed.

CANCEL: When a menu is displayed on the viewfinder screen, you can cancel any changed settings or return the display to the previous menu.

k MENU SEL (menu select) knob/ENTER button (rotary encoder)

To select settings from menus displayed on the viewfinder screen (by rotating the knob) and to confirm settings (by pushing the button).

You can change the ECS frequency by pushing the ENTER button when no menu is displayed on the viewfinder screen. Make sure that the camera is used in standalone status without connecting a camera control unit, and the shutter mode is set to ECS. When the camera is used in standalone status and the shutter mode is set to other than ECS, the VF DETAIL function can be adjusted.

Note

When a camera control unit or a remote control device, such as an MSU or RCP-series Remote Control Panel, is connected, the functions of 5 to 8 are controlled from the external control device and the controls on the camera are disabled.

7

Front left

abe c

df g

a DC power supply out connector (2-pin)

Supplies power to an external device up to 2.5 A.

b RET 1 (return video 1) button

The return video 1 signal from the camera control unit is monitored on the viewfinder screen while this button is pressed. It function the same as the RET 1 button on the handle (page 7) and RET/ASSIGNABLE button A on the operation panel on the rear of the camera (page 9).

You can also assign other functions to this button, using the menu displayed on the viewfinder screen.

c MIC 1 IN (microphone 1 input) connector (XLR 3-pin)

Connect a microphone.

This connector and the AUDIO IN CH-1 connector (page 10) on the operation panel on the rear of the camera are alternately activated with the CH1 audio input select switch (page 10).

d MIC (microphone) power switch

+48V: To supply a power of +48 V to the connected microphone.

OFF: Not to supply a power to the connected microphone.

e SHUTTER switch

For setting the electronic shutter functions when the camera is used in standalone status without connecting a camera control unit.

OFF: The electronic shutter does not function. ON: The electronic shutter is activated.

SEL: The shutter speed and shutter mode change each time the switch is set to this position.

For details, see “Setting the Electronic Shutter” on page 16.

f INTERCOM LEVEL control

To adjust the intercom/earphone volume level. The intercom level adjustment is enabled when the

INTERCOM LEVEL switch (page 9) on the rear of the camera is set to “FNT.”

g RET 2 (return video 2) button

When this button is pressed, the picture on the viewfinder screen changes to the return video signal selected using RET/ ASSIGNABLE button A, B, or C on the operation panel on the rear of the camera or using the menu.

You can also assign other functions to this button, using the menu displayed on the viewfinder screen.

Rear

 

 

b

 

Shoulder strap fitting

 

post (page 6)

 

Operation panel

 

(page 9)

 

c

 

d

 

e

a

Connector panel

(page 9)

 

 

f

a CAMERA POWER switch

 

CCU: Power is supplied from the camera control unit. EXT: Power is supplied through the DC IN connector.

b Tally lamp and switch

ON: The tally lamp lights when a tally signal is input to the connected camera control unit or a call signal is generated in response to pressing of a CALL button.

OFF: The tally lamp is prevented from lighting.

c RET 1/2 (return video 1/2) buttons

When pressed, the picture on the viewfinder screen changes to the return video signal selected using the operation panel on the rear of the camera or using the menu.

d CCU (camera control unit) connector

HDC3100: Connect a camera control unit using an optical electrical multi cable.

HDC3170: Connect a camera control unit using a triax cable.

e SDI 1 (serial digital interface 1) connector (BNC-type)

For 3G SDI, HD SDI or HD PROMPTER signal output.

On the HDC3100, in addition to the above signals, HD TRUNK signal input is supported.

For details on the output signals, see “Setting the Camera Outputs” (page 19).

f CALL button

When this button is pressed, the red tally lamp of the RCP-1500/1000 series Remote Control Panel or the MSU-1000-series Master Setup Unit will light. Use to call the operator of the RCP or MSU.

8

Operation panel

b

c

 

d

 

 

 

RET/ASSIGNABLE

 

 

 

LIGHT

A

B

C

DISP

 

 

 

 

 

ON

 

 

 

 

 

OFF

 

 

 

MENU

 

 

 

MIC

PROD

TRACKER

LEVEL

 

 

LINE

 

REAR

 

 

OFF

ENG

 

FNT

a

 

 

 

 

 

ENG

 

 

 

 

PGM2

control

 

 

 

 

control

PROD

 

PGM1

 

 

control

 

control

 

 

 

MIC

PROD

TRACKER LEVEL

 

 

LINE

 

REAR

 

 

OFF

ENG

 

FNT

 

 

INTERCOM

 

 

 

 

MIC LINE switch

 

 

 

TRACKER control

 

 

 

LEVEL switch

 

a INTERCOM controls and switches

ENG control, PROD control, PGM1 control, PGM2 control, MIC LINE switch, TRACKER control, and LEVEL switch for the intercom.

ENG (engineer line) control

Adjust the intercom audio listening level of the engineer line.

PROD (producer line) control

Adjust the intercom audio listening level of the producer line.

PGM1 (program 1) control

Adjust the audio listening level of program 1.

PGM2 (program 2) control

Adjust the audio listening level of program 2.

MIC LINE (intercom microphone line) switch

Select the intercom line.

PROD: Use the producer line. ENG: Use the engineer line.

OFF: Turn the intercom headset microphone off.

TRACKER control

Adjust the intercom audio listening level of an intercom connected to the TRACKER connector (page 10).

LEVEL switch

REAR: The intercom audio listening level is adjusted with the controls on the operation panel.

FNT: The intercom audio listening level is adjusted with the INTERCOM LEVEL control (page 8) on the front of the camera.

b LIGHT switch

Set to ON to illuminate the operation panel.

c RET/ASSIGNABLE button A, B

Press the button to switch the function assigned to the button on the <REAR FUNCTION ASSIGN> page on/off. When the return function is assigned, press the button to display the return video signal on the viewfinder screen while the button is pressed.

Turn the button to change the assigned function setting. When the return function is assigned, you can change the return signal channel.

d RET/ASSIGNABLE button C / DISP/MENU switch

Press the button to switch the function assigned to the button on the <REAR FUNCTION ASSIGN> page on/off. When the return function is assigned, press the button to display the return video signal on the viewfinder screen while the button is pressed.

Turn the button to change the assigned function setting. When the return function is assigned, you can change the return signal channel.

When the DISP/MENU switch is set to the MENU position to display the MENU screen, you can perform menu operations using RET/ASSIGNABLE button C.

Connector panel

 

 

 

 

 

 

f

 

 

 

 

 

 

g

 

 

 

EARPHONE

 

DC OUT

REMOTE

a

 

 

 

 

 

h

 

 

 

 

 

 

b

 

 

TRACKER

 

 

 

 

 

 

 

 

PROMPTER

 

 

 

 

 

/GEN

c

 

 

 

 

 

LOCK

RET CTRL

 

 

 

 

i

d

FRONT MIC

AES/EBU

 

 

LINE

MIC

LINE

MIC

 

TEST

 

+48V

 

+48V

 

 

 

OFF

 

OFF

 

OUT

 

DC IN 10.5-17V

AUDIO IN

 

 

j

 

CH1

 

CH2

 

 

 

 

 

e

 

 

 

 

 

SDI

 

 

 

 

 

MONI

 

 

 

 

 

k

 

 

 

 

 

 

 

 

 

l

 

 

 

a EARPHONE jack (4-pole mini jack)

Connect to a headset, or earphones with microphone (3-pole/ 4-pole earphones), to input/output the intercom audio signal. For 4-pole earphones, the intercom line is linked to the INTERCOM setting.

Turn the microphone function on/off using HEADSET MIC (page 38) in the OPERATION menu. When set to ON, the microphone can be turned on/off in conjunction with the INTERCOM setting using the MIC LINE switch on the operation panel. The default setting is OFF.

9

b USB connector (for connecting a USB drive)

Connect a USB drive to save or load the settings data file.

For details, see “Using a USB drive” (page 52).

c TRACKER connector (12-pin)

For external interface, such as intercom and tally.

d RET CTRL (return control) connector (6-pin)

For connection to a CAC-6 Return Video Selector.

e DC IN (DC power supply input) connector (XLR 4-pin)

Used for connection to the AC-DN10 AC Adaptor to supply power to the camera.

f INTERCOM connector (XLR 5-pin)

Used for input and output of intercom audio signals if an XLR 5-pin headset is connected.

The INTERCOM connector can be used for communication over the engineer line even when the power is off, as long as the power LED is lit in red.

g DC OUT (DC power supply output) connector (4-pin)

To supply power to devices such as a wireless receiver (optional) (max. 0.5 A).

h REMOTE connector (8-pin)

For connection to an RCP-1500/1000 series Remote Control Panel, or MSU-1000/1500 Master Setup Unit.

Note

When the camera is connected to a CCU, do not connect any remote control device, such as RCP and MSU, to this connector.

iPROMPTER/GENLOCK (prompter 1 signal output/ external gen-lock signal input) connector (BNC-type)

The PROMPTER function is enabled when a camera control unit is connected. The GENLOCK IN function is enabled when a camera control unit is not connected.

GENLOCK IN: For input of an external gen-lock signal (VBS or 3-level sync) during stand-alone operation.

PROMPTER: For output of the prompter 1 signal (valid only when a camera control unit is connected). When a camera control unit having two prompter inputs is connected, the signal of input 1 is output from this connector.

j TEST OUT connector (BNC-type)

To output the analog signal.

This can also output a VBS signal, HD-SYNC signal, or SD-SYNC signal, whichever is selected in the menu.

For details on the output signals, see “Setting the Camera Outputs” (page 19).

kSDI MONI (serial digital interface) connector (BNCtype)

For HD-SDI or SD-SDI signal output.

For details on the output signals, see “Setting the Camera Outputs” (page 19).

l AUDIO IN CH1 and CH2 connectors (XLR 3-pin) and switches

Connect audio signals. An input select switch and microphone power switch are provided for each channel.

CH1 audio input select switch

Microphone power switches

CH2 audio input select switch

FRONT MIC

AES/EBU

LINE

MIC

LINE

MIC

 

+48V

 

+48V

 

OFF

 

OFF

 

 

AUDIO IN

 

 

 

CH1

CH2

AUDIO IN CH1 connector

AUDIO IN CH2 connector

CH1 audio input select switch

Set to the appropriate position according to the equipment connected to the AUDIO IN CH1 connector.

LINE: When a line-level (0 dBu) signal source is connected

FRONT MIC: When using the microphone connected to the MIC 1 IN connector

MIC: When an external microphone is connected

CH2 audio input select switch

Set to the appropriate position according to the equipment connected to the AUDIO IN CH2 connector.

LINE: When a line-level (0 dBu) signal source is connected

AES/EBU: When a digital audio signal is connected (The signal must be in synchronization with the camera output).

MIC: When an external microphone is connected

Microphone power switches

When a microphone is connected to the corresponding AUDIO IN connector, set whether or not to supply a power to the microphone.

+48V: To supply a power of +48 V OFF: Not to supply a power

(No function has been assigned to the lowermost position. No power is supplied to the microphone.)

Note

To supply +12 V power, contact a Sony sales representative or Sony service representative.

10

Preparations

Attaching a Lens

For information on handling lenses, refer to the lens’ operation manual.

Attaching procedure

5

2

4

1,3

1 Push the lens fixing lever upwards and remove the lens mount cap from the lens mount.

2 Align the lens’ alignment pin with the notch in the upper part of the lens mount and insert the lens into the mount.

3 While supporting the lens, push the lens fixing lever downwards to secure the lens.

4 Connect the lens cable to the LENS connector.

5 Secure the lens cable with the cable clamp.

Adjusting the Flange Focal Length

Adjustment of the flange focal length (the distance between the lens mount attachment plane and the imaging plane) is necessary in the following situations:

The first time a lens is attached

When changing lenses

If the focus is not sharp at both telephoto and wide angle when zooming

The flange focal length can be more precisely adjusted by using the focus assist indicators.

See “Displaying the focus assist indicators” on page 17 for the focus assist indicators.

Note

The various parts of the lens used in adjusting the flange focal length are in different positions on different lenses. Refer to the operation manual for the particular lens.

Adjusting procedure

1 Set the iris control to manual, and open the iris fully.

2 Place a flange focal length adjustment chart approximately 3 meters from the camera and adjust the lighting to get an appropriate video output level.

3 Loosen the Ff (flange focal length) ring lock screw.

4 With either manual or power zoom, set the zoom ring to telephoto.

5 Aim at the flange focal length adjustment chart and turn the focus ring to focus the image.

About 3 meters (10 ft)

6 Set the zoom ring to wide angle.

7 Turn the Ff ring to bring the chart into focus. Take care not to move the distance ring.

8 Repeat steps 4 through 7 until the image is in focus at both telephoto and wide angle.

9 Tighten the Ff ring lock screw.

Attaching a Viewfinder

Caution

When the viewfinder is attached, do not leave the camera with the eyepiece facing the sun. Direct sunlight can enter through the eyepiece, be focused in the viewfinder and cause fire.

Attaching a viewfinder

This section describes using a HDVF-20A/200/EL20/EL30 (the HDVF-EL30 is shown in the diagrams).

For details on the viewfinder, refer to the operation manual of the viewfinder.

VF connector

Viewfinder stopper

11

1 Slide the viewfinder in the direction of the arrow.

The viewfinder stopper automatically pops down.

2 Loosen the viewfinder left-right positioning ring, slide the viewfinder side to side to the most convenient position and tighten the ring. (See “To adjust the position to the left or right” below.)

3 Connect the viewfinder cable to the VF connector of the camera.

Adjusting the viewfinder position

The viewfinder position may be adjusted towards the front and rear and to the left and right to make it easy to see into it.

To adjust the position to the left or right

Viewfinder left-right positioning ring

1 Loosen the viewfinder left-right positioning ring.

2 Slide the viewfinder left or right to move it into a good viewing position.

3 Tighten the viewfinder left-right positioning ring.

To adjust the position forward or backward

Viewfinder front-rear positioning lever

1 Set the viewfinder front-rear positioning lever to the unlocked position.

2 Slide the viewfinder towards the front or rear of the camera to move it into a good viewing position.

3 Set the viewfinder front-rear positioning lever to the lock position to secure the viewfinder.

Detaching the viewfinder

Loosen the viewfinder left-right positioning ring, pull the viewfinder stopper, then pull out the viewfinder by sliding it in the direction opposite to that when attached.

Attaching the Cable Clamp Belt (Supplied)

You can secure the optical/electrical multi cable or triax cable, connected to the CCU connector, to the side of the camera by attaching the supplied cable clamp belt.

1 Insert the belt bracket into hole A or B of the cable clamp belt.

Belt bracket

B

A

2 Peel off the cover seal from the camera as shown in the following diagram.

Cover seal

3 Secure the cable clamp belt to the camera, using the two supplied +B3×8 screws.

+B3×8 screws

12

Sony HDC-3100 User Manual

4 1 Release the buckle, 2 bundle the cable with the belt, 3 then lock the buckle again.

1

3

2

Optical/electrical multi cable or triax cable

5 Adjust the length by pulling down the end of the belt.

Adjusting the Shoulder Pad Position

You can shift the shoulder pad from its center position (factory setting) backward by up to 10 mm (3/8 inch) or forward by up to 25 mm (1 inch). This adjustment helps you get the best balance for shooting with the camera on your shoulder.

Adjusting procedure

Shoulder pad lock lever

 

1,3

 

Bottom of the camera

2

Shoulder pad

1 Raise the lever in the center of the shoulder pad to unlock the shoulder pad.

2 Slide the shoulder pad backward or forward until it is in the most convenient position.

3 Move the lever down to lock the shoulder pad in the selected position.

Mounting the Camera to a Tripod

Mount the camera to a tripod using a VCT-14 Tripod Attachment.

Caution

Select an appropriate hole from among those at the bottom of the tripod attachment considering the balance of the weight of the camera and the tripod attachment. If an inappropriate hole is selected, the camera may fall over.

Check that the size of the selected hole matches that of the screw of the tripod. If they do not match, the tripod attachment cannot be attached to the tripod securely.

Mounting procedure

1 Attach the tripod attachment to the tripod and secure it with the screw.

Tripod attachment

Platform of the tripod

13

2 Place the camera on the tripod attachment, and slide forward it along the groove of the tripod attachment until it clicks.

3 Make sure that the camera is securely attached by moving it back and forth.

To remove the camera from the tripod attachment

Hold down the red button and pull the lever in the direction of the arrow.

Lever

Red button

If the pin of the tripod attachment does not return to its original position

After removing the camera, if the pin of the tripod attachment does not return to its original position, hold down the red button and move the lever in the direction of the arrow to return the pin to its original position. It is not possible to mount a camera with the pin not seated.

Original position

Pin

Adjustments and Settings for Shooting

Adjusting the Black Balance and White

Balance

In order to maintain high picture quality, it is necessary to set the black balance and white balance appropriately for the conditions.

Note

When a camera control unit or a remote control device-such as the MSU or RCP series-is connected, control is performed from the RCP/MSU, and the switches on the camera are disabled.

Black balance adjustment

The black balance needs adjustment in situations like the following:

The first time the camera is used

When the camera is used after a long period of disuse

When the surrounding temperature changes greatly

When the gain value is changed using the setup menus Normally, there is no need to adjust the black balance every time the camera is turned on.

White balance adjustment

Always readjust the white balance when lighting conditions change.

About the viewfinder screen

After the process of adjusting the black balance or white balance begins, messages about the progress and results of the adjustment will be displayed on the viewfinder screen.

Note

Adjusted values set through automatic adjustment, and other settings, are stored in the camera’s memory and preserved even when the camera power is turned off.

Adjusting the black balance

Push the AUTO W/B BAL switch toward BLK (downward).

AUTO W/B BAL switch

Automatic adjustment of black balance begins.

In automatic adjustment of black balance, both the black set and black balance are adjusted.

14

During adjustment, a message like the one in the figure below will be displayed on the viewfinder screen.

ABB:EXECUTING

When the adjustment process is completed, the message “ABB: OK” will be displayed. The adjusted value is automatically stored in memory.

Notes

During black balance adjustment, the iris will be automatically closed.

During black balance adjustment, the gain switching circuit will work automatically, and the viewfinder screen will flicker several times. This is not a malfunction.

When automatic black balance adjustment fails

If the automatic black balance adjustment process does not end successfully, the error message “ABB: NG” will be displayed on the viewfinder screen for approximately three seconds.

If this error message is displayed, try black balance adjustment again.

If the error message continues to be displayed after several attempts, the camera requires internal inspection.

About black balance memory

The black balance values stored in memory will be preserved even when the camera power is turned off.

Adjusting the white balance

1 Set the WHITE BAL switch to A or B.

WHITE BAL switch

2 Select the filter setting using the filter select switch according to the lighting conditions.

3 Place a white pattern in the same lighting conditions as the subject, and zoom in on it so that a white area is obtained in the screen to satisfy the positional and quantitative requirements illustrated below.

A white object (white cloth, a white wall, etc.) near the subject may be used in place of a white pattern.

A rectangle centered in the screen. The length of the sides must be at least 70% of the height and width of the screen.

Within this rectangle, there must be an area of white greater than 10% of the entire screen.

Note

Be careful not to have any spots of high illumination in the rectangle.

4 Adjust the lens iris opening.

With a manually adjusted lens: Set the opening to an appropriate value.

With a lens which has automatic iris control: Set the lens’ automatic/manual iris control switch to automatic.

5 Push the AUTO W/B BAL switch to WHT and release the switch.

AUTO W/B BAL switch

The switch will return to the center position, and adjustment will be performed.

During adjustment, the message “AWB: EXECUTING” will be displayed on the viewfinder screen.

A message like the one in the figure below will be displayed, and the adjustment process will complete. The adjusted value will be automatically stored in the memory (A or B) selected in step 1.

AWB:OK

Note

When using a zoom lens with automatic iris control capability, hunting1) may occur. Adjust the lens’ iris gain control (labeled IG, IS, S, etc.).

15

1)Hunting: The automatic iris responds over and over, and the image repeatedly darkens and lightens.

For more information, refer to the lens’ operation manual.

When automatic white balance adjustment fails

If the white balance adjustment process does not end successfully, the error message “AWB: NG” will be displayed on the viewfinder screen for approximately three seconds.

If this error message is displayed, try white balance adjustment again.

If the error message continues to be displayed after several attempts, the camera requires internal inspection.

When there is no time to adjust the white balance

Set the WHITE BAL switch to PRST. The white balance will be set automatically according to the filter settings.

About white balance memory

The white balance values stored in memory will be preserved even when the camera power is turned off.

There are two white balance memories, A and B. When the AUTO W/B BAL switch is pushed to the WHT side, the white balance will be adjusted automatically according to the filter settings. The adjusted value will be stored in the selected memory. Each memory can store up to five adjusted values, for a total of 10.

Setting the Electronic Shutter

This section explains the different modes which can be used for the electronic shutter and gives the procedures for setting the shutter mode and shutter speed.

Note

When a camera control unit or a remote control device, such as MSU-1000/1500 Master Setup Unit and RCP-1500/1000 series Remote Control Panel, is connected, the electronic shutter is controlled from the external control device and control on the camera are disabled.

About the shutter modes

The shutter modes that can be used with the electronic shutter of the camera and the shutter speeds that may be selected are as follows:

Shutter modes and speeds

Shutter mode

Shutter speeds*

Usage

Standard

1/100, 1/125, 1/250,

Use to obtain clear images

 

1/500, 1/1000, 1/2000

of quickly moving subjects

 

seconds

 

 

 

 

ECS (Extended

Continuously variable in

Use to obtain images on

Clear Scan)

the range of 59.96 Hz to

video monitors without

 

4300 Hz

horizontal striping

 

 

 

*The values in the table are those with 59.94i. With other formats, the available values are different.

Note

With artificial lighting, particularly fluorescent lights and mercury vapor lamps, the brightness appears to be constant, but in fact the strength of the red, green, and blue components varies with the power supply frequency. This phenomenon is known as “flicker.” When using the electronic shutter under these lighting conditions, there are certain cases in which the flicker is more noticeable. In particular, color flicker is evident when the power frequency is 60 Hz. In areas where the power

frequency is 50 Hz, setting the shutter speed to 1/100 second will reduce the flicker.

Selecting the shutter mode and speed

The shutter mode, and the shutter speed in standard mode, are set using the SHUTTER switch.

Setting the shutter mode, and shutter speed in Standard mode

1 Push the SHUTTER switch from the ON position to the SEL position.

SHUTTER switch

The current shutter setting will be displayed in the setting change/adjustment progress message display area of the viewfinder screen for about three seconds.

Example: “SHUTTER: 1/250”

2 Push the SHUTTER switch to the SEL position again before the display disappears. Repeat this action until the desired mode or speed is displayed.

When all modes and speeds are displayed, they will be displayed in the following order:

Example: with 59.94i

Standard mode

1/100 1/125 1/250 1/500 1/1000 1/2000

ECS mode

Setting the Focus Assist Functions

Using the OPERATION menu, the assist functions for easier focusing on the viewfinder, can be activated.

Adding the VF detail signal

Adding the VF detail signal to sharp edges in the image on the viewfinder screen makes it easier to check the focusing condition by observing changes in the detail signal or in the color converted from the detail signal (color detail).

The focus setting where the detail signal becomes strongest is the best focus setting.

1 Turn on the camera.

2 Set the DISPLAY switch to MENU while holding the MENU SEL knob/ENTER button pressed.

The camera enters Menu mode, and “TOP” is displayed at the upper right corner of the screen.

16

3 Rotate the MENU SEL knob/ENTER button to align the arrow marker (,) to “TOP” and push on the MENU

SEL knob/ENTER button.

The TOP MENU screen is displayed.

<TOP MENU>

USER

USER MENU CUSTOMIZE

ALL

OPERATION

PAINT

MAINTENANCE

FILE

DIAGNOSIS

4 Rotate the MENU SEL knob/ENTER button to align the arrow marker (,) to OPERATION and push on the

MENU SEL knob/ENTER button.

The CONTENTS page of the OPERATION menu is displayed.

CONTENTS

00 TOP

01.<VF DISPLAY> 02.<'!'IND> 03.<VF MARKER> 04.<VF DETAIL>

05.<FOCUS POSITION METER1 06.<FOCUS POSITION METER2 07.<FOCUS ASSIST> 08.<ZEBRA>

09.<CURSOR>

10.<BOX CURSOR FILE>

5 Rotate the MENU SEL knob/ENTER button to align the arrow marker (,) to <VF DETAIL> and push on the

MENU SEL knob/ENTER button.

The <VF DETAIL> page is displayed.

<VF

DETAIL>

 

04 TOP

VF

DETAIL

:

ON

(25%)

CRISP

 

:

0

 

FREQUENCY:

9M

 

FLICKER

:

OFF

AREA

 

:

70%

ZOOM

LINK:

ON

100%

COLOR

DETAIL

:

ON BLUE

PEAK

COLOR

:

ON

CHROMA LEVEL:

100%

6 Rotate the MENU SEL knob/ENTER button to align the arrow marker (,) to the item to be set and push on the MENU SEL knob/ENTER button.

To use the VF detail signal

Set VF DETAIL to ON to activate the VF detail function to add the detail signal to sharp edges in the image. You can adjust the signal level (strength) in the range of 0 to 100% (default 25%).

You can adjust the characteristics of the detail signal with the menu items below.

CRISP: Adjust to eliminate fine portions of the detail signal.

FREQUENCY: Change the detection band of sharp edges.

FLICKER: Turn ON/OFF the function to flicker the detail signal, which makes it easier to check the signal on a viewfinder screen.

AREA: To limit the area where to display the detail signal. ZOOM LINK: Set the VF detail level at the full WIDE

position. (The VF detail level changes according to the zoom position.)

To use the color detail

Set COLOR DETAIL to ON to convert the VF detail signal to a specified color. This makes it easier to check the signal on an LCD screen, including the viewfinder screen. The display color can be selected at the column next to ON.

You can adjust the coloring with the menu items below. PEAK COLOR: Turn ON/OFF the function to change the

color where the detail signal is strongest. CHROMA LEVEL: To reduce the chroma components of

the video signal (only for video signals on the viewfinder).

7 Rotate the MENU SEL knob/ENTER button to display the desired setting and push on the MENU SEL knob/ ENTER button.

8 To finish the adjustment, set the DISPLAY switch to OFF to exit Menu mode.

Displaying the focus assist indicators

The focus assist indicator function extracts the irregularities of a subject and converts the integrated values to a level indicator, which shows the focus condition.

Level indicator (its position and operations can be adjusted.)

Area marker to display the detection area of the focus (its size and position can be adjusted.)

The focus setting where the indicator shows the maximum level is the best focus setting. (The range of the indicator substantially changes depending on picture elements or shooting environments. Adjust it with GAIN and OFFSET as required.)

1 Display the CONTENTS page of the OPERATION menu (referring to step 1 to 4 in “Adding the VF detail signal”).

2 Rotate the MENU SEL knob/ENTER button to align the arrow marker (,) to <FOCUS ASSIST>and push on the MENU SEL knob/ENTER button.

The <FOCUS ASSIST> page is displayed.

<FOCUS ASSIST>

07 TOP

INDICATOR

: OFF

 

MODE

: BOX

BOTTOM

LEVEL

:

3

QUICK

GAIN

:

50

 

OFFSET

:

50

 

AREA MARKER:

ON

 

SIZE

:

MIDDLE

 

POSITION

:

CENTER

 

POSITION

H:

50

 

POSITION

V:

50

 

 

 

 

 

3 Rotate the MENU SEL knob/ENTER button to align the arrow marker (,) to the item to be set and push on the MENU SEL knob/ENTER button.

To use the level indicator

Setting INDICATOR to ON displays the level indicator on the viewfinder.

17

Loading...