Redmond RHF-3301 User Manual

4.3 (9)

Ultrasonic humidifier

Ультразвуковой увлажнитель воздуха

Befeuchtungsapparat der Luft Humidificateur d’air

RHF-3301

EN

RHF-3301

Ultrasonic humidifier

Instruction for use

RU

RHF-3301

Ультразвуковой увлажнитель воздуха

Инструкция по применению

DE

RHF-3301 Befeuchtungsapparat der Luft

Gebrauchsanweisung

FR

RHF-3301 Humidificateur d’air

Mode d`emploi

EN: For your own safety read these instructions carefully before using the appliances.

RU: В целях Вашей собственной безопастности, перед использованием изделия

внимательно прочитайте настоящую инструкцию.

DE: Wegen eigener Sicherheit lesen Sie aufmerksam diese Gebrauchsanweisung vor dem

Gebrauch der Anlage.

FR: Avant que vous utiliser cet appareil, lisez bien ce mode d`emploi pour votre sécurité.

Redmond RHF-3301 User Manual

ENGLISH

EN

Model description

RU

Описание модели

DE

Die Musterbeschreibung

FR

La description du modèle

 

1

 

2

 

3

 

4

7

 

8

 

9

5

 

10

6

11

 

Режим

Пар

Пар

Реж. Стан. Здор.

Кожа Увл.

Уст.

 

 

Увлаж.

Комн. Темп. Влаж.

Таймер

EN

DE

1.

Direction mist nozzle

1.

Richtungsnebel-Schnauze

2.

Water tank

2.

Wasserzisterne

3.

Cap

3.

Kappe

4.

Air outlet

4.

Luftauslass

5.

Control Panel

5.

Bedienungsfeld

6.

Power Switch

6.

Macht-Schalter

7.

Water Line Protective Switch

7.

Wasserlinie Schutzschalter

8.

Connector

8.

Stecker

9.

Flume

9.

Klamm

10.

Unit Base

10.

Einheitsbasis

11. Power Cord

11. Macht-Schnur

12.

Mode Setting

12. Weise, die

13.

Humidity Setting

13.

Untergeht. Feuchtigkeit, die

14.

Mist Intensity Control

14.

Untergeht.

15.

Time Setting

 

 

Nebel-Intensitätskontrolle

16.

Mist Intensity Display

15.

Zeit, die

17. Mode Display

16. Untergeht.

18.

Humidity Display

 

 

Nebel-Intensitätsanzeige

19.

Water Scarce Display

17.

Weise-Anzeige

20.

Room Temperature Display

18.

Feuchtigkeitsanzeige

21. Time Display

19. Knappe Wasseranzeige

 

 

 

20. Raumtemperatur Zeigt

RU

21.

Zeitanzeige

 

 

 

1.

Носик

FR

2.

Водный резервуар

3.

Крышка водного

1.

Ajutage de brouillard

 

резервуара

 

de direction

4.

Воздуховыпускное

2.

Réservoir d’eau 3. Bonnet

 

отверстие

4.

Issue aérienne

5.

Панель управления

5. Pupitre de commande

6.

Кнопка электропитания

6. Changement de Pouvoir

7.

Защитное устройство,

7. Ligne D’eau Changement

 

отключающее прибор

 

Protecteur

 

при опустошении резервуара.

8.

Connecteur

8.

Ультразвуковой

9.

Ravin

 

преобразователь

10.

Base d’Unité

9.

Водосборник

11. Corde de Pouvoir

10.

Платформа

12. Mode Mettant

11.

Сетевой кабель

13. Humidité Mettant

12.

Кнопка выбора режима

14.

Contrôle d’Intensité

13.

Кнопка выбора режима

 

 

de Brouillard

 

 

увлажнения

15. Temps Mettant

14.

Кнопка выбора

16.

Étalage d’Intensité

 

 

интенсивности паро–

 

 

de Brouillard

 

 

выделения.

17.

Étalage de Mode

15.

Кнопка выбора

18.

Étalage d’Humidité

 

 

периода времени

19.

Étalage Rare D’eau

16.

Индикатор интенсивности

20. La Température

 

 

паровыделения

 

 

de Pièce Affiche

17.

Индикатор выбранного

21.

Étalage de Temps

 

 

режима

 

 

 

18.Индикатор величины влажности

19.Индикатор наличия воды в водном резервуаре

20.Индикатор величины температуры в помещении

21.Индикатор выбранного периода времени

2

Instruction for use

ENGLISH

Dear Customer,

Thank you for preferring the domestic electric appliance manufactured by REDMOND. REDMOND means quality, reliability and thoughtful attitude towards our clients.

We hope that you will select products of our firm in future, and the brand REDMOND will become predominant among your domestic appliances.

IMPORTANT SAFEGUARD

When using any electric appliance, basic precautions should always

be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

Read the instructions carefully before use, and save them for future reference.

Make sure the power used corresponds to the one indicated on the rating label.

Always have water in the water tank when operating the unit.

Use only clean, cool tap water to fill tank. (Softened or distilled water is recommended in hard water areas).

Ensure the filling cap at the bottom of the water tank is firmly tightened.

Always have the mist nozzle, and the mist chamber in place while the unit is operating. Rotate the mist nozzle so it is aimed away from children, walls, and furniture.

Place the humidifier on a smooth level surface.

Always disconnect the humidifier from the mains supply when not in use, and when cleaning.

This appliance is intended for household use only.

Do not leave the humidifier “ON” unattended.

Never cover the humidifier when operational as this could damage the unit.

Unplug the unit when not in use, and whenever cleaning or moving the unit.

Do not add aromatherapy oils into the nozzle, base or water tank.

Do not cover any openings of the unit or insert objects into any of the openings.

Do not tilt or tip unit or attempt to empty or fill it while it is operating.

Do not immerse the humidifier in water or let water come into contact with the connector, or control device.

Do not attempt to open any part of the humidifier.

Keep the humidifier clean. Do not allow objects to enter the ventilation, as this may damage the unit.

Close supervision is required when any appliance is used near or by children.

Never allow the cord to touch wet or hot surfaces, become twisted or be within the reach of children.

Do not use outdoors.

Do not place on or near hot gas or an electric burner.

Never use the appliance with a damaged cord or plug or after the appliance has malfunctioned or been damaged in any way.

Never attempt to open any part or dismantle the controls. Responsibility for failure cannot be accepted if these instructions have been ignored.

Do not use the appliance for anything other than its intended use.

Any repairs that need to be done to the humidifier must be referred to an authorized Service Agent only.

The unit should not be left unattended in closed rooms as air could become saturated and leave condensation on walls or furniture.

Do not use detergent to clean any parts containing water. The detergent can interfere with the output of the unit if it comes into contact with the water.

Always leave room door partly open.

3

ENGLISH

OPERATION

Carefully remove your humidifier from the carton, and take off all the protective wrapping.

Place the humidifier on a firm, level surface free from obstructions.

For first using, please put the humidifier in a room with normal temperature. After half an hour, it can be operated.

Working temperature: 5°C-40°C, relative humidity: ≤80%RH

Using water less than 40°C (purified water is recommended).

Remove the water tank from the base of unit, open the cap and fill from bottom with water.

Close the cap and put the water tank on the base correctly.

Put the nozzle in the notch of water tank and adjust the nozzle away from walls and furniture.

Plug the humidifier into a power outlet.

To turn on the humidifier (never switch it on without water). The power indicator will illuminate. You may see the status bar from the screen. It shows the highest mist output, humidification display, current room temperature and current humidity.

If setting different modes, press the button of “mode setting”.

There are four modes: standard/health/skin protect/humidification. It is convenience for people to choose. (Under mode “Humidification”, mist intensity is the highest.)

Standard: According to room temperature, it will control the humidity and restrain the virus.

Health: The humidity level will be controlled at about 60% RH, that will be comfortable to people.

Skin Protect: The humidity level will be controlled at about 70%RH. It can help people to dispel crinkle.

Humidification: It will be at the position of spray without the influence of environment humidity.

Press the button of “Пар”, you can set 4 levels of mist intensity according to your room.

Press the button of “Увлажнение”. Set humidity comfortable for you. When the room humidity is higher than that shows on the screen, the humidifier will stop to spray. Once the room humidity is lower than which shows on the screen, the humidifier starts to spray again.

Press the button of “Таймер” and set time from 2 hours to 16 hours. (2hrs/4hrs/8hrs/12hrs/16hrs).

When there is no water in the water tank, the icon glimpses to remind people to fill water in

the water tank.

Note: It is normal if there is a little of mist overflows from the nozzle at the beginning of working.

CLEANING YOUR ULTRASONIC HUMIDIFIER

Note: When cleaning the inside of the unit, keep the water away from the air outlet.

The method of keeping clean:

Using purified water

Cleaning the base of unit, water tank and connector every week

Always change to use clean water.

Always drain the water tank when not in use.

Clean all parts of the humidifier before storing by wiping with a damp cloth,

4

Instruction for use

ENGLISH

and buffing with a dry cloth.(Except for the electrical control when the unit is off, any part of the humidifier may be wiped with a soft damp cloth, and buffed with a dry cloth ,ensuring the unit is unplugged.)

The methods of cleaning the connector:

To drip down 5–10 drops of the detergent on the surface of the connector and dip in for 2–5 minutes.

To clean the dirty surface with soft brush.

Rinse the connector with clean water.

The methods of cleaning the base of unit:

Clean the dirty flume with soft cloth dipping with detergent.

If there is dirty on the surface of the protective switch of water line, using soft brush to clean with detergent.

Wash the flume with clean water.

OTHER FEATURES

In cold weather, windows, and even some walls may fog or develop frost from excessive indoor humidity. If this occurs, reduce the mist intensity setting to avoid damage from condensed water dripping on windowsills.

Too much humidity in the room may allow moisture to accumulate on surfaces where bacteria and fungi can grow. Collected moisture may also harm furniture, and walls, especially wallpaper. To eliminate too much humidity, especially in a small room, leave the room door open, add adjust the mist intensity control setting.

SPECIFICATIONS

Model No.

RHF-3301

 

Consumption

38W

 

Water tank

5 Litres

 

 

 

 

 

 

Capacity

 

 

 

 

 

 

 

 

 

Voltage

220–240V

 

Moisture output

≥260ml/h

 

Net Weight

2.8 Kgs

 

 

 

 

 

 

 

 

Frequency

50Hz

 

Noise

≤35dB (A)

 

Frequency

3.6 Kgs

 

 

 

 

 

 

 

 

CHECK THE MALFUNCTION AND REPAIR

If your humidifier can’t work, please ask the service department to repair:

 

MALFUNCTION

CAUSATION

RESOLVE METHODS

 

 

 

 

 

 

Didn’t connect the power supply

Connect the humidifier from

1.

Power indicator can’t work

the power supply

 

 

and with no wind and mist

Didn’t turn on the humidifier

Switch on the unit

 

 

 

 

 

 

2.

Power indicator illuminate,

No water in the water tank

Fill water in water tank

the unit with wind but no mist

 

 

 

 

 

 

New humidifier

Open water tank, put it in

 

 

shadow for 12 hours

3.

Smelly mist

 

 

 

Dirty water or long–time to

Clean the water tank, fill clean

 

 

 

 

store water in water tank

water in

 

 

 

 

4.

Power indicator illuminate,

Too much water in the base

Empty the flume, then close

the unit with no wind and mist

flume

the cap of water tank

 

 

 

 

5

Loading...
+ 15 hidden pages