Panasonic CS-C12BKPG, CU-2C24BKP5G, CU-C14BKPG, CU-2C23BKP5G Service Manual

0 (0)
Order No. MAC0201007C2
Multi-Split Air Conditioner
CS-C12BKPG CU-2C24BKP5G CS-C14BKPG CU-2C23BKP5G CS-C9BKPG
CONTENTS
Page Page
1 Features 2 2 Functions 3 Product Specifications 4 Dimensions 5 Refrigeration Cycle Diagram 6 Block Diagram 7 Wiring Diagram 8 Operation Details 9 Operating Instructions 10 Installation Instructions
11 3-way Valve 40 12 Servicing Information
3 6
13 Troubleshooting Guide 14 Technical Data
10 12
15 Exploded View
13
16 Replacemen t Parts List 17 Exploded View
15 17
18 Replacemen t Parts List 19 Electronic Parts List
25 30
20 Electronic Circuit Diagram
© 2002 Matsushita Air-Conditioning Corp. Sdn. Bhd. (183914D). All rights reserved. Unauthorized copying and distribution is a violation of law.
47 51 53 55 56 57 58 60 61
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
1 Features
High Efficiency
Compact Design
Comfort Improvement
Longer hours of sleep mode operation
Air filter with function to reduce dust and smoke
Wider range of horizontal discharge air
Auto Restart
Random auto restart after power failure for safety restart
operation
Removable and Washable Front Panel
Remote Control Self-illuminating Button
Catechin Air Purifying Filter
Trap dust, tobacco smoke and tiny particles
Prevent the growth of bacteria and viruses trapped
Solar Refreshing Deodorizing Filter
Remove unpleasant odour from the air
Quality Improvement
Gas leakage protection
Prevent compressor reverse cycle
Low voltage protection
Operation Improvement
Economy mode to reduce electrical power consumption
Powerful mode to reach the desired room temperature
quickly
Installation Work Improvement
Long piping up to 15 meter
24-hour Timer Setting
Service Improvement
Easy fan motor replacement procedure
2
2 Functions
Remote Control
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
Self illuminating
button
OFF / ON I
MODE
FAN SPEED
AIR SWING
POWERFUL
Operation OFF / ON
Operation Mode Selection
AUTO COOL DRY FAN
Automatic Operation Mode Cooling Operation Mode Soft Dry Operation Mode Air Circulation Mode
Indoor Fan Speed Selection
FAN
Low Fan Speed
FAN
Medium Fan Speed
FAN
High Fan Speed
AUTO FAN
Automatic Fan Speed
Vertical Airflow Direction Control
AUTO
Automatic Vertical Airflow Direction Control
MANUAL
Vertical Airflow Direction Manual Control (5 stages of adjustment)
Powerful Mode Operation OFF/ON
TEMP.
ON-TIMER OFF-TIMER
TIME
SET CANCEL
CLOCK
Room Temperature Setting
Cooling, Soft Dry, Air Circulation Operation.
• Temperature Setting (16°C to 30°C) Automatic Operation
Operation with 2°C higher than standard temperature.
Operation with standard temperature.
Operation with 2°C lower than standard temperature.
Timer Operation Selection
• 24-hour, OFF / ON Real Timer Setting.
Time / Timer Setting
• Hours and minutes setting.
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and cancellation.
Clock Setting
• Current time setting.
ECONOMY
Economy Mode Operation OFF/ON
3
SLEEP
Sleep Mode Operation OFF / ON
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
Indoor Unit
AUTO
OFF / ON
Automatic Operation Button
Random Auto Restart Control
Press for < 5s to operate Automatic operation mode. (Used when the remote control cannot be used.)
Press continuously for 5s or < 10s to operate Test Run/Pump down. “Beep” sound will be heard at the 5th second. (Used when test running or servicing.)
Press continuously for 10s and above to omit or resume the remote control signal receiving sound. Beep, beep sound will be heard at the 10th second.
Operation Indication Lamps (LED)
POWER
(Green) ........Lights up in operation,
blinks in Automatic Operation Mode judging.
SLEEP
(Orange)........ Lights up in Sleep
Mode Operation.
TIMER
(Orange) .......Lights up in Timer
Setting.
POWERFUL
(Orange)..Lights up in Powerful
Mode Operation.
ECONOMY
(Green) ..... Lights up in Economy
Mode Operation.
Operation Mode
Cooling, Soft Dry, Air Circulation and Automatic Mode.
Powerful Operation
Reaches the desired room temperature quickly.
Operation is restarted randomly after power failure at previous setting mode.
Anti-Freezing Control
Anti-Freezing control for indoor heat exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
Indoor Fan operates at Low speed.
Operation stops after 8 hours.
Indoor Fan Speed Control
High, Medium and Low.
Automatic Fan Speed Mode Cooling : Fan rotates at Hi, Me and
SLo speed. Deodorizing control is available.
Soft Dry: Fan rotates at SLo speed.
Deodorizing control is available.
Airflow Direction Control
Automatic air swing and manual adjusted by remote control for vertical airflow.
Manually adjusted by hand for horizontal airflow.
Starting Current Control
Fan motor is delayed for 1.6 seconds when compressor starts simultaneously.
Time Delay Safety Control
Restarting is inhibited for appro. 3 minutes.
Economy Operation
To reduce electrical power consumption.
7 Minutes Time Save Control
Cooling Operation only.
Anti-Dew Formation Control
Anti-Dew Formation Control for indoor unit discharge area.
4
Outdoor Unit
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
Compressor Reverse Rotation Protection Control
To protect compressor from reverse rotation when there is a instantaneous power failure.
Overload Protector for Compressor
Inner protector (For 2C24BK only).
Overload Protector will trip when High temperature or high current flows
to compressor. (Refer circuit diagram for OLP characteristic)
60 Secs. Forced Operation Control
Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal.
Overload Protector for Fan Motor
Inner protector.
5
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
3 Product Specifications
Unit CS-C12BKPG CU-2C24BKP5G
Power Source Phase
Cooling Capacity kW
Moisture Removal l/h
Airflow Method OUTLET
Air Volume Indoor Air (Lo) m3/min (cfm) 7.3 (260) - 7.3 (260)
Indoor Air (Me) m3/min (cfm) 8.7 (310) - 8.7 (310) Indoor Air (Hi) m3/min (cfm) 10.2 (360) - 10.2 (360) Indoor Air (SHi) m3/min (cfm) 10.5 (370) - 10.5 (370)
V
Cycle
kcal/h
Pint/h
INTAKE
(1 unit) 3.52 - 3.46
3,023 - 2,975.5
(1 unit) 2.0
4.2
SIDE VIEW TOP VIEW
Single
230 - 220
50
(2 units) 7.03 - 6.92
6,046 - 5,951
(2 units) 4.0
8.4
Noise Level dB (A) High 39 - 39, Low 29 - 29 High 55 - 54
Power level dB High 52 - 52 High 68 - 67
Electrical Data Input W (1 unit)
Running Current A (1 unit)
COP W/W (1 unit) 2.98 - 2.93 (2 units) 2.98 - 2.94
Starting Current A (1 unit) 27 (2 unit) 54
Piping Connection Port (Flare piping)
Pipe Size (Flare piping)
Drain Hose
Dimensions Height inch (mm) 10 - 13/16 (275) 26 - 31/32 (685)
Net Weight lb (kg) 20 (9.0) 159 (72) Compressor Type Rotary (1 cylinder)
Inner diameter mm 12 Length m 0.7
Width inch (mm) 31 - 15/32 (799) 34 - 21/32 (880) Depth inch (mm) 8 - 9/32 (210) 13 - 19/32 (345)
Motor Type Induction (2-poles) Rated Output W A: 950 B: 950
inch inch
inch inch
1,180 - 1,180
5.35 - 5.45
G ; Half Union 1/2
L ; Half Union 1/4 G (gas side) ; 1/2
L (liquid side) ; 1/4
(2 units)
2,360 - 2,350
(2 units)
10.7 - 10.9
G ; 3-way valve 1/2
L ; 3-way valve 1/4
G (gas side) ; 1/2
L (liquid side) ; 1/4
rolling piston type
6
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
Air Circulation Type Cross-flow Fan Propeller Fan
Material AS + Glass Fiber 20% AS + Glass Fiber 20%
Motor Type Induction (4-poles) Induction (6-poles)
Input W 29.3 - 26.3 87 Rated Output W 15 50
Fan Speed Low rpm 900 - 900
Medium rpm 1,080 - 1,080 High rpm 1,260 - 1,260 870 SuperHigh rpm 1,300 - 1,300
Heat Exchanger Description Evaporator Condenser
Tube material Copper Copper Fin material Aluminium Aluminium Fin Type Slit Fin Corrugated Fin Row / Stage (Plate fin configuration, forced draft)
2×15 2×26 FPI 21 16 Size (W × H × L) mm 610 × 315 × 25.4 826 × 663.9 × 44
Refrigerant Control Device Capillary Tube Refrigeration Oil (c.c) SUNISO 4GDID or ATMOS M60
Refrigerant (R-22) g (oz) 930 × 2 (32.8 × 2) Thermostat Electronic Control — Protection Device Internal Overload Protector Capillary Tube Length mm 500
Flow Rate l/min 15.2 Inner Diameter mm 1.5
Air Filter Material
Style
Capacity Control Capillary Tube Compressor Capacitor µF, VAC 35 µF, 370 VAC Fan Motor Capacitor µF, VAC 1.5 µF, 400 VAC 3.0 µF, 450 VAC
(c.c) P.P.
Honeycomb
(410 × 2)
Specifications are subject to change without notice for further improvement.
7
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
Unit
Power Source Phase
V
Cycle
Cooling Capacity kW
kcal/h
One Unit (A)
CS-C14BKPG
(A) 4.11 - 4.06
3,533 - 3,491
One Unit (B) CS-C9BKPG
Single
230 - 220
50
(B) 2.64 - 2.61
2,272 -
CU-2C23BKP5G
(A+B) 6.75 - 6.67
5,805 - 5,736
2,245
Moisture Removal l/h
Pint/h
Airflow Method OUTLET
(A) 2.3
4.9
(B) 1.6
3.4
(A+B) 3.8
8.0
SIDE VIEW TOP VIEW
INTAKE
Air Volume Indoor Air (Lo) m3/min (cfm) 7.3 - 7.3 (260 - 260) 6.8 - 6.8 (240 - 240)
Indoor Air (Me) m3/min (cfm) 8.7 - 8.7 (310 - 310) 8.0 - 8.0 (280 - 280) Indoor Air (Hi) m3/min (cfm) 10.2 - 10.2 (360 - 360) 9.9 - 9.9 (350 - 350) Indoor Air (SHi) m3/min (cfm) 10.5 - 10.5 (370 - 370) 10.9 - 10.9 (380 - 380)
Noise Level dB (A) (A)
Power level
dB
(A+B)
(A)
(A+B)
High 39 - 39 Low 29 - 29 High 39 - 39 Low 29 - 29
High 52 - 52 High 50 - 50
(B) High 36 -
36 Low 26 ­26
(B) High 49 -
49
(A) (B)
(A+B)
(A) (B)
(A+B)
High 55 - 54 High 55 - 54 High 55 - 54
High 68 - 67 High 68 - 67 High 68 - 67
Electrical Data Input W (A) 1,410 - 1,380 (B) 900 - 890 (A+B) 2,310 - 2,270
Running Current A (A) 6.33 - 6.45 (B) 4.07 - 4.15 (A+B) 10.4 - 10.6
COP W/W (A) 2.91 - 2.94 (B) 2.93 - 2.93 (A+B) 2.92 - 2.94
Starting Current A (A) 31.1 (B) 18.8 (A+B) 49.9
Piping Connection Port (Flare piping)
Pipe Size (Flare piping)
Drain Hose
Inner diameter mm 12 Length m 0.7
inch inch
inch inch
G ; Half Union 1/2,3/8
L ; Half Union 1/4,1/4 G (gas side) ; 1/2, 3/8
L (liquid side) ; 1/4,1/4
G ; 3-way valve 1/2,3/8
L ; 3-way valve 1/4,1/4
G (gas side) ; 1/2,3/8
L (liquid side) ; 1/4,1/4
Dimensions Height inch (mm) 10 - 13/16 (275) 26 - 31/32 (685)
Width inch (mm) 31 - 15/32 (799) 34 - 21/32 (880)
Depth inch (mm) 8 - 9/32 (210) 13 - 19/32 (345) Net Weight lb (kg) 20 (9.0) 146 (66) Compressor Type Rotary (1 cylinder)
rolling piston type Motor Type Induction (2-poles) Rated Output W (A) 1,200 (B) 700 (A+B) 1,900
8
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
Air Circulation Type Cross-flow Fan Propeller Fan
Material AS + Glass Fiber 20% AS + Glass Fiber 12%
Motor Type Induction (4-poles) Induction (6-poles)
Input W (A) 28.7 - 27.1 (B) 20.6 - 19.1 87 Rated Output W (A) 15 (B) 15 50
Fan Speed Low rpm (A) 900 - 900 (B) 780 - 780
Medium rpm (A) 1,080 - 1,080 (B) 920 - 920 High rpm (A) 1,260 - 1,260 (B) 1,140 - 1,140 870 SuperHigh rpm (A) 1,300 - 1,300 (B) 1,250 - 1,250
Heat Exchanger Description Evaporator Condenser
Tube material Copper Copper Fin material Aluminium Aluminium Fin Type Slit Fin Corrugated Fin Row / Stage (Plate fin configuration, forced draft)
(A) 2 × 15 (B) 2 × 15 2 × 26 FPI 21 19 16 Size (W × H × L) mm 610 × 315 × 25.4 826 × 663.9 × 44
Refrigerant Control Device Capillary Tube Refrigeration Oil (c.c) SUNISO 4GDID or ATMOS
Refrigerant (R-22) g (oz) (A) 1,060 (37.4)
Thermostat Electronic Control Protection Device Overload Protector Capillary Tube Length mm (A) 430 (B) 370
Flow Rate l/min (A) 19.5 (B) 12.8 Inner Diameter mm (A) 1.7 (B) 1.4
Air Filter Material
Style
Capacity Control Capillary Tube Compressor Capacitor µF, VAC 30 µF, 370 VAC Fan Motor Capacitor µF, VAC 1.5 µF, 400 VAC 3.0 µF, 450 VAC
(c.c) P.P.
Honeycomb
M60 (A) 410, (B) 270
(B) 640 (22.6)
Specifications are subject to change without notice for further improvement.
9
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
4 Dimensions
10
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
11
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
5 Refrigeration Cycle Diagram
12
6 Block Diagram
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
13
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
14
7 Wiring Diagram
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
15
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
16
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
8 Operation Details
8.1. Cooling Mode Operation
Cooling in operation according to Remote Control setting.
Time Delay Safety Control (3 minutes)
When the compressor is stopped by Remote Control, it restarts after 3 minutes when the Remote Control is turned ON.
When the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3 minutes.
7 minutes Time Save Control
The compressor will start automatically if it has stopped for 7 minutes even if the room temperature is between the compressor
ON temperature and OFF temperature.
Starting Current Control
When the compressor outdoor fan motor and indoor fan motor are simultaneously started, the indoor fan motor will operate 1.6
second later.
Anti-Freezing Control
If the temperature of the indoor heat exchanger falls
continuously below 2°C for 4 minutes or more, the compressor turns off to protect the indoor heat exchanger from freezing. The fan speed setting remains the same.
Compressor will restart again when the indoor heat
exchanger temperature rises to 10°C (Recovery).
3 minutes waiting of Time Delay Safety Control is valid for Cooling Operation.
Compressor Reverse Rotation Protection Control
If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and
indoor heat exchanger is 2.5°C or less for 2 minutes, compressor will stop and restart automatically. (Time Delay Safety Control is valid)
T = Intake air temperature - Indoor heat exchanger temperature
This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
Anti-Dew Formation Control
Purpose is to prevent dew formation on indoor unit air discharge area.
When the following conditions accur for 30 minutes continuously, anti-dew formation is controlled by indoor fan speed shift to
low (CLo to HLo):
Indoor intake air temperature is more than 24°C and less than 30°C.
Remote Control setting temperature is less than 25°C.
Compressor is on.
Cooling operation mode.
Indoor Fan motor operate at Low fan speed.
This control is cancelled immediately when above condition is changed.
17
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
Fan speed rotates in the range of Hi to Me.
Deodorizing Control.
Cooling Operation Time Diagram
18
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
8.2. Soft Dry Mode Operation
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start. During Soft Dry operation, the Indoor Fan will operate at SLo speed.
The operation will be switched on and off for up to 10 minutes ONand 6 minutes OFF. Once Soft Dry operation is turned
off, it stops for 6 minutes.
Time Delay Safety Control
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Starting Current Control
Same as Starting Current Control for Cooling Mode operation.
Anti-Freezing Control
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
Compressor Reverse Rotation Protection Control
Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
Anti-Dew Formation Control
Same as Anti-Dew Formation Control for Cooling Mode operation.
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
Fan speed off and on at SLo speed.
Deodorizing Control.
19
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
Soft Dry Operation Time Diagram
20
CS-C12BKPG CU-2C24BKP5G / CS-C14BKPG CU-2C23BKP5G / CS-C9BKPG
8.3. Air Circulation Mode Operation
When the temperature near the ceiling reaches the setting temperature, Air Circulation Mode operation commences at low
airflow volume. It stops when the temperature drops to 2°C below the setting temperature.
Air Circulation Mode Operation Time Diagram
8.4. Automatic Mode Operation
Standard for Determining Operation Mode
Indoor fan operates at SLo fan speed for 25 seconds.
After judging indoor air temperature, the operation mode is determined and operation continued at the mode determined.
After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation includes
Cooling mode operation. Room temperature adjustment.
The following are added to the setting temperature specified as above.
The mode judging temperature and standard setting temperature can be increased by 2°C, by open the circuit of JX1 at indoor
electronic controller.
21
Loading...