GT25-05UCOV

Thank you for purchasing Mitsubishi Electric Graphic Operation Terminal.

Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.

MODEL

GT25-UCOV-U-JE

MODEL

1D7MI2

CODE

 

IB(NA)-0800501-E(2004)MEE

© 2013 MITSUBISHI ELECTRIC CORPORATION

lSAFETY PRECAUTIONSl

(Always read these precautions before using this equipment.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.

The precautions given in this manual are concerned with this product.

In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates that incorrect handling may cause hazardous

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

conditions, resulting in death or severe injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates that incorrect handling may cause hazardous

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

conditions, resulting in medium or slight personal injury

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or physical damage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note that the CAUTION level may lead to a serious accident according to the circumstances.

Always follow the precautions of both levels because they are important to personal safety.

Please save this manual to make it accessible when required and always forward it to the end user.

[INSTALLATION PRECAUTIONS]

CAUTION

[DISPOSAL PRECAUTIONS]

CAUTION

Dispose of this product as industrial waste.

[TRANSPORTATION PRECAUTIONS]

CAUTION

When fumigants that contain halogen materials such as fluorine, chlorine, bromine, and iodine are used for disinfecting and protecting wooden packaging from insects, they cause malfunction when entering our products. Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products, or treat packaging with methods other than fumigation (heat method).

Additionally, disinfect and protect wood from insects before packing products.

Manuals

The following shows manuals relevant to this product.

Manual name

Manual number (Model code)

 

 

GOT2000 Series User’s Manual (Hardware)

SH-081194ENG (1D7MJ5)

 

 

For detailed manuals and relevant manuals, refer to the e-Manual or PDF manuals stored in the DVD-ROM for the screen design software used.

The latest manuals are also available from MITSUBISHI ELECTRIC FA Global Website (www.MitsubishiElectric.com/fa).

Referenced Standard: GB/T15969.2 (Requirement of Chinese standardized law)

Packing List

After unpacking the box, check that the following products are included.

·

 

 

Model

Product

Quantity

 

GOT2000 series USB environmental protection

1

GT25-UCOV

cover

 

GT21-WUCOV

Fixing screw (M3 x 6)

1

GT25-05UCOV

GOT2000 Series USB Environmental Protection

1

 

Cover User's Manual (This manual)

 

 

1. OVERVIEW

This user's manual describes the USB environmental protection cover of the GOT2000 series (hereinafter referred to as the USB environmental protection cover).

The USB environmental protection cover is for protection of the USB interface.

The following table shows the USB environmental protection cover models and applicable GOTs.

Model

Screen sizes for the applicable GOTs

 

The following GOTs with the USB interface on their front faces

 

· 15" models

GT25-UCOV

· 12.1" models

 

· 10.4" models

 

· 8.4" models

 

The following GOTs with the USB interface on their front faces

GT21-WUCOV

· 10.1" wide models

· 7" wide models

 

 

· GT2505-VTBD

GT25-05UCOV

GT2705-VTBD

The USB environmental protection cover is used to make the USB interface complaint with the protective structure IP67F*1.

*1: The suffix "F" of IP67F is a symbol that indicates protection rate against oil. It is described in the Appendix of Japanese Industrial Standard JIS C 0920.

2. SPECIFICATIONS

The following shows the performance specifications of the USB environmental protection cover.

The general specifications of the USB environmental protection cover are the same as those of the GOT.

For the general specifications of the GOT, refer to the GOT2000 Series User's Manual (Hardware).

Item

Description

 

 

Protective structure*1

IP67F

 

 

Weight

0.005 kg

 

 

*1: The USB interface is IP67F-rated when the USB environmental protection cover is installed to the GOT.

To conform to IP67F, close the USB environmental protection cover by pushing in the [PUSH] mark or [PULL] mark firmly to lock the cover.

(The USB interface is IP2X-rated when the USB environmental protection cover is open.)

3.EXTERNAL DIMENSIONS

3.1GT25-UCOV

 

 

1)

 

 

2)

 

 

3)

66.1

(2.60)

 

 

 

4)

15.7

7

Unit: mm (inch)

(0.62)

(0.28)

 

No.

Name

Description

 

 

 

1)

Hinge

Hinge for opening or closing the USB environmental

protection cover

 

 

 

 

 

2)

Hinge projection

Hinge projection to be fitted in the GOT guiding hole

 

 

 

3)

Packing

Packing for protecting the USB interface

 

 

 

4)

Latch

Latch for fixing or opening the USB environmental

protection cover

 

 

 

 

 

3.2 GT21-WUCOV

1)

2)

3)

51.5

(2.03)

4)

11.55.1

 

 

(0.45)

 

 

(0.20)

 

 

 

 

 

 

 

Unit: mm (inch)

 

 

 

 

 

 

 

No.

 

Name

 

 

Description

 

 

 

 

 

 

 

1)

Hinge

Hinge for opening or closing the USB environmental

protection cover

 

 

 

 

 

 

 

 

 

 

 

2)

Hinge projection

Hinge projection to be fitted in the GOT guiding hole

 

 

 

 

 

 

 

3)

Packing

Packing for protecting the USB interface

 

 

 

 

 

 

 

4)

Latch

For locking or unlocking the USB environmental

protection cover

 

 

 

 

 

 

 

 

 

 

 

3.3 GT25-05UCOV

 

 

1)

 

 

2)

 

 

3)

71

(2.80)

 

 

 

4)

15.5

7

Unit: mm (inch)

(0.61)

(0.28)

 

No.

Name

Description

 

 

 

1)

Hinge

Hinge for opening or closing the USB environmental

protection cover

 

 

 

 

 

2)

Hinge projection

Hinge projection to be fitted in the GOT guiding hole

 

 

 

3)

Packing

Packing for protecting the USB interface

 

 

 

4)

Latch

Latch for fixing or opening the USB environmental

protection cover

 

 

 

 

 

Make sure to securely fix the USB environmental protection cover onto the GOT using fixing screws and tighten the screws in the specified torque of 0.36 N•m to 0.48 N•m. Loose tightening may cause the USB environmental protection cover to drop off and/ or the GOT to fail or malfunction.

Overtightening may damage and drop screws and/or the USB environmental protection cover.

When closing the USB environmental protection cover, fix the cover to the GOT by pushing the [PUSH] or [PULL] mark on the latch firmly to comply with the protective structure.

4.INSTALLATION AND REMOVAL

4.1Installing the USB Environmental Protection Cover

4.1.1 GT25-UCOV, GT25-05UCOV

The installation procedure for the USB environmental protection cover is explained using GT2712.

1) Get up the hinge of the USB environmental protection cover.

2)Align the hinge projection of the USB environmental protection cover on the guiding hole of the GOT.

Put a supplied fixing screw through the hinge hole of the USB environmental protection cover.

Fixing screw

3)Tighten the fixing screw in the specified torque range (0.36 N•m to 0.48 N•m) to fix the cover to the GOT.

4)When you do not use the USB interface, close the USB environmental protection cover by pushing in the [PUSH] mark on the cover firmly.

5)To use the USB interface, open the USB environmental protection cover by pushing the [PUSH] mark on the cover.

4.1.2 GT21-WUCOV

The installation procedure for the USB environmental protection cover is explained using GT2510-WX.

1) Get up the hinge of the USB environmental protection cover.

2)Align the hinge projection of the USB environmental protection cover on the guiding hole of the GOT.

Put a supplied fixing screw through the hinge hole of the USB environmental protection cover.

Fixing screw

3)Tighten the fixing screw in the specified torque range (0.36 N•m to 0.48 N•m) to fix the cover to the GOT.

4)When you do not use the USB interface, close the USB environmental protection cover by pushing in the [PULL] mark on the cover firmly.

When you close the USB environmental protection cover, make sure that the latch is fully retracted into the cover body.

Otherwise, the USB environmental protection cover may get damaged.

5)To use the USB interface, unlock the USB environmental protection cover by sliding its latch and then open the cover.

4.2 Removing the USB Environmental

Protection Cover

Perform the reverse procedure of installation for removing the USB environmental protection cover.

5. PRECAUTIONS FOR USE

1)When the USB environmental protection cover is closed, the USB interface is IP67F-rated.

In this case, the USB environmental protection cover must be locked into position by pushing in the [PUSH] mark or [PULL] mark firmly.

2)The USB environmental protection cover is a consumable product.

Check the cover periodically. When the cover has damage, heavy soil, and others, replace the cover.

Warranty

Mitsubishi Electric will not be held liable for damage caused by factors found not to be the cause of Mitsubishi Electric; machine damage or lost profits caused by faults in the Mitsubishi Electric products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi Electric; damages to products other than Mitsubishi Electric products; and to other duties.

For safe use

This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.

This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

Country/Region

Sales office/Tel

USA

Mitsubishi Electric Automation, Inc.

 

 

500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A.

 

 

Tel: +1-847-478-2100

Brazil

Mitsubishi Electric do Brasil Comercio e Servicos Ltda.

 

 

Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil

 

 

Tel: +55-11-4689-3000

Mexico

Mitsubishi Electric Automation, Inc. Mexico Branch

 

 

Boulevard Miguel de Cervantes Saavedra 301, Torre Norte Piso 5, Ampliacion Granada,

 

 

Miguel Hidalgo, Ciudad de Mexico, Mexico, C.P.11520

 

 

Tel: +52-55-3067-7512

Germany

Mitsubishi Electric Europe B.V. German Branch

 

 

Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany

 

 

Tel: +49-2102-486-0

UK

Mitsubishi Electric Europe B.V. UK Branch

 

 

Travellers Lane, UK-Hatfield, Hertfordshire, AL10 8XB, U.K.

 

 

Tel: +44-1707-28-8780

Italy

Mitsubishi Electric Europe B.V. Italian Branch

 

 

Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7,

 

 

20864 Agrate Brianza (MB), Italy

 

 

Tel: +39-039-60531

Spain

Mitsubishi Electric Europe B.V. Spanish Branch

 

 

Carretera de Rubi, 76-80-Apdo. 420, E-08190 Sant Cugat del Valles (Barcelona), Spain

 

 

Tel: +34-935-65-3131

France

Mitsubishi Electric Europe B.V. French Branch

 

 

25, Boulevard des Bouvets, 92741 Nanterre Cedex, France

 

 

Tel: +33-1-55-68-55-68

Czech

Mitsubishi Electric Europe B.V. Czech Branch

 

 

Pekarska 621/7, 155 00 Praha 5, Czech Republic

 

 

Tel: +420-255 719 200

Turkey

Mitsubishi Electric Turkey A.S. Umraniye Branch

 

 

Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey

 

 

Tel: +90-216-526-3990

Poland

Mitsubishi Electric Europe B.V. Polish Branch

 

 

ul. Krakowska 48, 32-083 Balice, Poland

 

 

Tel: +48-12-347-65-00

Russia

Mitsubishi Electric (Russia) LLC St. Petersburg Branch

 

 

Piskarevsky pr. 2, bld 2, lit "Sch", BC "Benua", office 720; 195027 St. Petersburg, Russia

 

 

Tel: +7-812-633-3497

South Africa

Adroit Technologies

 

 

20 Waterford Office Park, 189 Witkoppen Road, Fourways, South Africa

 

 

Tel: +27-11-658-8100

China

Mitsubishi Electric Automation (China) Ltd.

 

 

Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China

 

 

Tel: +86-21-2322-3030

Taiwan

SETSUYO ENTERPRISE CO., LTD.

 

 

6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan

 

 

Tel: +886-2-2299-2499

Korea

Mitsubishi Electric Automation Korea Co., Ltd.

 

 

7F to 9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu,

 

 

Seoul 07528, Korea

 

 

Tel: +82-2-3660-9569

Singapore

Mitsubishi Electric Asia Pte. Ltd.

 

 

307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943

 

 

Tel: +65-6473-2308

Thailand

Mitsubishi Electric Factory Automation (Thailand) Co., Ltd.

 

 

12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road,

 

 

Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand

 

 

Tel: +66-2682-6522 to 31

Indonesia

PT. Mitsubishi Electric Indonesia

 

 

Gedung Jaya 8th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia

 

 

Tel: +62-21 3192-6461

Vietnam

Mitsubishi Electric Vietnam Company Limited

 

 

11th & 12th Floor, Viettel Tower B, 285 Cach Mang Thang 8 Street, Ward 12,

 

 

District 10, Ho Chi Minh City, Vietnam.

 

 

Tel: +84-28-3910-5945

India

Mitsubishi Electric India Pvt. Ltd. Pune Branch

 

 

Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune - 411026, Maharashtra, India

 

 

Tel: +91-20-2710-2000

Australia

MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD.

 

 

348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W 2116, Australia

 

 

Tel: +61-2-9684-7777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice. Printed in Japan, April 2020.

Loading...