LG SP122HM US1, SP091CM US1, SP122HM UT1, SP092CM NT0, SP121CM NY2 Owner's Manual

...
0 (0)
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating your set and retain it for future reference.
P/NO:MFL67445111
www.lg.com
SP092CM
NY0
SP092CM
UY0
TYPE:WALL MOUNTED
MODELS
ENGLISH ESPAÑOL
ENGLISH
ESPAÑOL
SP092CM
NT0
SP092CM
US0
SP122HM
US1
SP122HM
UT1
SP091CM
NT1
SP091CM
US1
SP121CM
NY2
SP121CM
US2
SP121CM
UY2
SP121HM
NT1
SP122CM
NT1
SP122CM
US1
SP122CM
UT1
SP182CM
N54
SP182CM
U54
SP242CM
N54
SP242CM
US4
SP242CM
U54
SP242HM
US2
SP242HM
U52
SP122HM
NT1
SP091CM
UT1
SP121HM
US1
SP182CM
US4
SP242HM
N52
2 Room Air Conditioner
Room Air Conditioner Owner’s Manual
TABLE OF CONTENTS
Display Luminosity(Optional) ..............14
......................15
To Cancle The Timer Setting...............15
Sleep Mode .........................................15
......................
Jet Cool
...............................................17
Forced Operation.................................17
E. Maintenance and Service..................18
Indoor Unit...........................................18
Outdoor Unit ........................................20
Operation Tips!....................................20
Self-Diagnosis Function ......................20
Troubleshooting Tips!
Save time and money!.........................21
Call the service immediately in the
following situations ..............................21
Spec sheet...........................................22
A. Safety Precautions ..............................3
B. Electrical Safety...................................6
Temporary Use of an Adapter ...............6
Temporary Use of an Extension Cord ...6
Symbols used in this Manual.................6
C. Product Introduction...........................7
Indoor Units ...........................................7
Operation Indication Lamps ..................8
Outdoor Unit ..........................................8
D. Operating Instructions........................9
How to insert the Batteries ....................9
Wireless Remote Controller
Maintenance..........................................9
Operating Method..................................9
Wireless Remote Controller
Operation Mode...................................12
.....13
Air Circulation Operation
.....................14
Auto Clean Operation..........................14
Cooling Only Model ..........................10
Wireless Remote Controller
Heat Pump Model .............................11
Airflow Direction Control
16
Auto Operation.....................................13
Healthy Dehumidification Operation
Timer Setting Operation
Setting the Current Time......................14
FOR YOUR RECORDS
Write the model and serial numbers here:
You’ll find many answers to common problems in the
Inside you will find many helpful hints on how to use
You can find them on a label on the side of each unit.
Model # Serial #
Dealer's Name Date Purchased
Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
READ THIS MANUAL
and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips
for service at all.
first, you may not need to call
PRECAUTION
Contact the authorized service technician for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by authorized personnel only using only genuine replacement parts.
Plug in the power plug properly.
Otherwise, it will cause electric shock or fire due to heat generation or electric shock.
Do not operate or stop the unit by inserting or pulling out the power plug.
Do not operate with wet hands or in damp environment.
Do not direct airflow at room occupants only.
Do not allow water to run into electric parts.
Do not use the socket if it is loose or damaged.
Do not open the entrance during operation.
Always perform grounding work.
Always install air leakage breaker and a dedicated switching board.
Unplug the unit if strange sounds,smell,or smoke comes from it.
It will cause electric shock or fire due to heat generation.
In the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly
Do not damage or use an unspecified power cord.
It will cause electric shock or fire.
It will cause electric shock or fire due to heat generation.
It may cause electric shock.
It may cause failure of machine or electric shock.
No grounding may cause electric shock.
No installation may cause fire and electric shock accident.
It may cause fire and electric shock accident.
It may cause fire and electric shock.
It may cause electric shock.
This could damage your health.
Do not modify power cord length or share the outlet with other appliances.
quallfied order to avoid a hazard.(Y Attachment)
ENGLISH
There is risk of fire or electric shock.
Avoid personal injury.
It may cause corrosion on the product.
A bad connection may cause water leakage.
Install the drain hose to ensure that the condensed water is drained away properly.
Do not use the telephone or turn switches on or off. There is risk of explosion or fire.
product on.
Two or more peopie must lift and transport the product.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
Do not place ANYTHING on the power cable.
Do not plug or unplug the power supply plug to turn the unit ON/OFF.
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the
Harsh detergent may also cause failure of product, fire, or electronic shock.
Do not use harsh detergent that causes corrosion or damage on the unit.
For inner cleaning, contact an Authorized Service Center or a dealer.
Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals.
Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after
Improper or loose connections can cause heat generation or fire.
Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the
Children may play with them and cause injury.
Incorrect refrigerant used can prevent the normal operation of the unit.
Don’t use a power cord, a plug or a loose socket which is damaged.
Otherwise it may cause a fire or electrical shock.
Do not touch, operate, or repair the product with wet hands. Hold the plug by hand when taking out.
Do not place a heater or other heating appliances near the power cable.
Do not allow water to run into electric parts.Install the unit away from water sources.
Do not store or use or even allow flammable gas or combustibles near the product.
Do not use the product in a tightly closed space for a long time. Perform ventilaion regularly.
Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if
If strange sounds, smell or smoke comes from product. Immediately turn the breaker off or
Be sure to check the refrigerant to the used. Please read the label on the product.
Dirty, loose or broken power plug can cause electric shock or fire.
plug completely.
installation or svc and then tear away and thraw away the plastic packaging bags.
There is risk of electric shock or fire.
There is risk of fire and electric shock.
There is risk of electric shock or fire.
There is risk of electric shock.
There is risk of product damage or failure, or unintended operation.
There is risk of fire or electric shock.
There is risk of fire or electric shock.
This could result in personal injury and product damage.
Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit.
Take care to ensure that power cable could not be pulled out or damaged during operation.
breaker.
When the product is not to be used for a long time, disconnect the power supply plug or turn off the
element etc.
Turn the main power off and unplug the unit when cleaning or repairing the product.
There is risk of fire, failure of the product, or electric shock.
There is risk of fire.
There is risk of physical injury, electric shock, or product failure.
the unit is so equipped.)
disconnect the power supply cable.
Ventilate the product room from time to time when operating it together with a stove, or heating
Oxygen deficiency could occur and hence harm your health.
Oxygen deficiency can occur and hence harm your health.
It may cause a problem for your neighbors and hence dispute.
Low refrigerant levels may cause failure of product.
There is risk of damage or loss of property.
It may cause product failure.
Do not touch the metal parts of the product when removing the air filter.
Do not step on or put anyting on the product. (outdoor units)
Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if
Be cautious when unpacking and installing the product.
If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
There is risk of personal injury.
necessary.
There is risk of personal injury and failure of product.
There are sharp and moving parts that could cause personal injury.
A dirty filter reduces the efficiency.
Sharp edges could cause injury.
Do not tilt the unit when removing or uninstalling it.
Do not mix air or gas other than the specified refrigerant used in the system.
The refrigernat gas can cause frostbite (cold burn)
The condensed water inside can spill.
damage or injury.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and
accordance with local and national standards.
If the refrigerant gas leaks during the installation, ventilate the area immediately.
Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in
If air enters the refrigerant system, an excessiveiy high pressure results, causing equipment
Otherwise it can be harmfull for your health.
There is risk of fire or product failure.
There may bum or explode.
Moisture may condense and wet or damage furniture.
This could harm to your health.
It is not sanitary and could cause serious health issues.
Be careful and avoid personal injury.
The chemicals in batteries could cause burns or other health hazards.
use the remote if the batteries have leaked.
window is left open.
Do not expose your skin or kids or plants to the cool or hot air draft.
Do not drink the water drained from the product.
Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not
new batteries or different types of batteries.
Do not recharge or disassemble the batteries. Do not dispose off batteries in a fire.
Do not insert hands or other objects through the air inlet or outlet while the product is operating.
consumer air conditioner, not a precision refrigeration system.
Do not block the inlet or outlet of air flow.
Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a
Always check for gas (refrigerant) leakage after installation or repair of product.
To avoid vibration or noise.
the neighborhoods.
Do not install the product where the noise or hot air from the outdoor unit could damage or disturb
Keep level even when installing the product.
ENGLISH
6 Room Air Conditioner
Electrical Safety
Electrical Safety
• This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet.
• Do not cut or remove the grounding prong from the power plug.
• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
• Never use the appliance with a broken adapter.
We strongly discourage the use of an extension cord due to potential safety hazards.
Temporary Use of an Adapter
Temporary Use of an Extension Cord
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
This symbol indicates special notes.
NOTE
Symbols used in this Manual
This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.
Owner's Manual 7
Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type.
Product Introduction
Product Introduction
Standard Split Type
Art Cool Type Wide
Display panel LED indicators
Air inlet
3M multi protection filter&Plasma filter (Optional)
Air filter
Air outlet
Front grille ON/OFF button
Signal
receiver
Grille tab
Flap
(Horizontal blade)
Louvers
(Vertical blades)
Indoor Units
ENGLISH
Art Cool Deluxe(Type 1) Display panel LED indicators
Signal receiver
Front panel
Air discharge
Power cord
ON/OFF button
Plasma filter
Air inlet
Air filter
Art Cool Deluxe(Type 2) Display panel LCD indicators
Signal receiver
Front panel
Air discharge
ON/OFF button
Power cord
Plasma filter
Air inlet Air filter
8 Room Air Conditioner
Product Introduction
Air intake vents
Air outlet vents
Connecting wires
Refrigerant pipes
Drain hose
Base plate
On/Off
: Lights up during the system operation, error code and auto restart setting.
Sleep mode : Lights up during sleep mode auto operation.(non-Inverter Model)
Plasma : The function illustrates its dynamic mode by using a multiple lighting system.
Timer
: Lights up during timer operation.(non-Inverter Model) Lights up during timer operation or sleep mode auto operation (Inverter Model only)
Defrost mode
Power Display : Indicates the setting temperature and operation mode.
: Lights up during defrost mode or hot start operation (Heat pump model only) : Lights up during outdoor unit operation. (Cooling model only)
Outdoor unit operation
OUT
DOOR
! Hot start operation: Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out
from unit. ! In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat exchanger coils to maintain the efficiency.
Operation
mode
Shape of
display
Setting
temperature
Standard Too hot Hot Cold Too cold
Jet
Cool/Heat
Test
operation
Auto
clean
Comfortable
Auto operation mode
Cooling, heating, Dehumidification
Mode
Energy-saving
cooling mode
Outdoor Unit
Operation Indication Lamps
Owner's Manual 9
Operating Instructions
How to insert the Batteries
Wireless Remote Controller Maintenance
1. Remove the battery cover by pulling it according to the arrow direction.
2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
3. Reattach the cover by sliding it back into position.
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the batteries to save their working life.
3. If the display screen of remote controller starts, fading replace both of the batteries.
4. Use 2 AAA(1.5 volt) batteries.
NOTE
1. Choose a suitable place where its safe & easy to reach.
2. Fix the holder to wall etc with the supplied screws firmly.
3. Slide the remote controller inside the holder.
1. Remote controller should never be exposed to direct sunlight.
2. Signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.
3. In case some other appliances also get operated with remote control, change their position or consult your serviceman.
1. The signal receiver is inside the unit.
2.
Aim the remote controller towards the unit to operate it. There should not be any blockage in between.
NOTE
Operating Instructions
Operating Method
ENGLISH
Operating Instructions
Cooling Operation
Auto Operation or Auto Changeover
Operation Mode
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
RESET BUTTON
Used prior to resetting time.
LED LUMINOSITY BUTTON (OPTIONAL)
Used to adjust LED luminosity.
JET COOL BUTTON
Used to start or stop the speed cooling. The Jet Cool operates fan in super high speed in cooling mode.
SLEEP MODE AUTO BUTTON
Used to set sleep mode auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating.
10
13
7
16
8
2
9
Flip-up door (opened)
Wireless Remote Controller (Cooling Only Model)
The controls will look like the following.
Healthy Dehumidification Operation
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
AUTO CLEAN BUTTON
Used to set auto clean.
AUTO CLEAN
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
INDOOR FAN SPEED SELECTION BUTTON
Used to select fan speed in four steps low, medium, high and natural wind.
HORIZONTAL VANE CONTROL BUTTON
Used to set the desired vertical airflow direction.
ON/OFF BUTTON
Used to turn off/on the unit.
TIME SETTING BUTTONS
Used to adjust the time.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
ON
OFF
TIMER SET/CANCEL BUTTON
Used to set and to cancel the timer operation.
SET
CANCEL
2nd F BUTTON
Used prior to using modes printed in blue at the bottom of buttons.
Signal transmitter
ON
OFF
CANCEL
AUTO CLEAN
SET
1
3
15
4
11
14
5
6
1
2
Room Air Conditioner10
To use the functions printed in blue at the bottom of the buttons press 2
nd
F button first and then the required function
button. Pressing the 2
nd
F button activates the blue printed function of the respective button. To cancel the function
press the 2nd F button again else it will automatically cancel if remains idle after 10 seconds.
NOTE
Operating Instructions
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
AUTO CLEAN BUTTON
Used to set auto clean.
AUTO CLEAN
INDOOR FAN SPEED SELECTION BUTTON
Used to select fan speed in four steps low, medium, high and natural wind.
HORIZONTAL VANE CONTROL BUTTON
Used to set the desired vertical airflow direction.
To use the functions printed in blue at the bottom of the buttons press 2
nd
F button first and then the required function
button. Pressing the 2
nd
F button activates the blue printed function of the respective button. To cancel the function
press the 2nd F button again else it will automatically cancel if remains idle after 10 seconds.
ON/OFF BUTTON
Used to turn off/on the unit.
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
TIME SETTING BUTTONS
Used to adjust the time.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
ON
OFF
TIMER SET/CANCEL BUTTON
Used to set and to cancel the timer operation.
SET
CANCEL
RESET BUTTON
Used prior to resetting time.
LED LUMINOSITY BUTTON (OPTIONAL)
Used to adjust LED luminosity.
JET COOL BUTTON
Used to start or stop the speed cooling. The Jet Cool operates fan in super high speed in cooling mode.
SLEEP MODE AUTO BUTTON
Used to set sleep mode auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating.
2nd F BUTTON
Used prior to using modes printed in blue at the bottom of buttons.
Cooling Operation
Auto Operation or Auto Changeover
Healthy Dehumidification Operation
Heating Operation
Operation Mode
The controls will look like the following.
ENGLISH
Signal transmitter
ON
OFF
CANCEL
AUTO CLEAN
SET
1
3
15
4
10
13
7
16
8
2
9
13 11
14
5
6
12
Flip-up door (opened)
NOTE
Wireless Remote Controller (Heat Pump Model)
Owner's Manual 11
ENGLISH
ENGLISH
Operating Instructions
Healthy
Dehumidification
Open the cover of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
2
(For Heating Model)
Open the cover of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
(For Cooling Model)
Heating
(Heat pump model only)
Cooling Auto Operation
Cooling
Healthy
Dehumidification
Auto Operation
Press the ON/OFF BUTTON to Turn on the unit The unit will respond with a beep.
For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS. For cooling the temperature can be set within 18°C~30°C and for heating the temperature range is 16°C~30°C.
Set the fan speed with the remote controller. You can select the fan speed in four steps : low, medium, high and natural wind by pressing the INDOOR FAN SPEED SELECTION BUTTON Each time the button is pressed, the fan speed mode is shifted in the direction of the arrow.
1
3
4
Natural wind
For fresher feeling, press the INDOOR FAN SPEED SELECTION BUTTON and set to Natural wind mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed.
Step1(Low) Step2(Medium) Step3(High)Natural Wind
Operation Mode
Room Air Conditioner12
If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON, the product starts to run the dehumidification
function. It automatically sets the room temperature and airflow volume to the best
condition for dehumidification, based on the sensed current room temperature. In this case, however, the setting temperature is not displayed on the remote controller and you are not able to control the room temperature either.
During the healthy dehumidification function, the fan speed is automatically set
according to the optimization algorithm responding to the current room
temperature status, so that the room condition is kept healthy and comfortable
even in the very humid season.
Healthy Dehumidification Operation
During Healthy Dehumidification Operation
Operating Instructions
<For Cooling Model>
The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you feel hot or cold, press TEMPERATURE SETTING buttons for more cooling or heating effect. You cannot switch the indoor fan speed. It has already been set by the Auto Operation Mode rule.
Auto Operation
Code Feel Cold Slightly cool Neutral Slightly warm Warm
Please select the code
as per your requirement.
You can set desired temperature and indoor fan speed. Setting Temp. Range : 18~30°C.
: You can not set the actual setting temperature and the fan
speed in this operation mode. But you can use the Auto swing in this operation. If the system is not operating as desired, switch manually to another mode
NOTE
<For Heating Model>
13Owner’s Manual
ENGLISH
ENGLISH
Operating Instructions
During Auto Clean fuction, only ON/OFF button, Plasma button, Auto Clean button is used. During this operation, 'Cooling Lamp' lights up.
Display LuminosityOptional
The unit display luminosity can be adjusted by using the remote controller. Open the cover of the remote controller and press the LED LUMINOSITY BUTTON. Display LED will be off. Press the button again to set bright display.
During Auto Clean Operation, moistures left in indoor units after cooling operation or healthy dehumidification operation can be removed.
Select Auto Clean Operation by the function setting button( ).
Now whenever the unit is turned off, the indoor fan is still running for
about 30 minutes internally without cooling or dehumidification
operation. This function dries up any remains of moisture & cleans
the unit internally. If you push the Auto Clean button again, this function is
cancelled.
NOTE
Auto Clean Operation
AUTO CLEAN
AUTO CLEAN
This operation circulates the air without cooling or heating. It can be activated by pressing the AIR CIRCULATION BUTTON. Once the air circulation is activated you can select the fan speed by pressing the INDOOR FAN SPEED SELECTION BUTTON.
Air Circulation Operation
Room Air Conditioner14
Time can be set only when you press the RESET BUTTON. Having replacing the batteries, you should press the RESET BUTTON to reset the time. Press the ON/OFF BUTTON.
Press 2ndF button and check if icon is on.
Check the indicator for a.m. and p.m.
NOTE
Setting the Current Time
2
Press the TIME SETTING BUTTONS until the desired time is set.
3
Press the TIMER SET/CANCEL BUTTON.
4
1
CANCEL
SET
Loading...
+ 31 hidden pages