ower in Motion
LG Variable Frequency Drive(VFD) : Inverter
Starvert iG5
0.37 - 4.0kW (0.5 - 5.4HP) 1 and 3 phase 200 - 230 Volts, 3 phase 380 - 460 Volts
Contents |
|
Overview |
02 |
Features & Selection Guide |
04 |
Specifications & Wiring |
06 |
Terminal Configuration, Keypad & Parameter Navigation |
08 |
Program Parameter Descriptions |
10 |
Dimension |
12 |
DB Resistor, Options & Peripheral Devices |
14 |
Overview
Compact iG5,
is the best for a small and cost effective configuration.
Standard features
kW / Voltage Ratings:
0.5 ~ 2HP, 200-230VAC, 1phase
0.5 ~ 5HP, 200-230VAC, 3phase
0.5 ~ 5HP, 380-460VAC, 3phase
Enclosure: IP00 ~ IP20
Inverter Type: PWM with IGBT
Control Method: Volts / Hertz with Space Vector Technology
Built-in RS-485 Built-in ModBus-RTU
Built-in PID control
Removable keypad (Able to read & write parameter)
150% torque at 0.5Hz Trip-free operation algorithm
8 preset speeds
3 jump(skip) frequencies 3 Multifuctional inputs
1 Multifuctional output
Analog output (0~12V)
PNP and NPN dual directional signals
Speed search
3 wire operation
1 to 10 kHz carrier frequency
Built-in Braking transistor
Manual/Auto torque boost
Options
Cable for Remote Keypad Operations(2,3 and 5 meters) DIN rail base for easy installation
Application
|
Converting |
|
Commercial washing machine |
|
|
||
|
Fan |
|
Grinder |
|
|
||
|
|
||
|
Pump |
|
Textile machine |
|
|
||
|
|
||
|
Food processing machine |
|
Material handling machine |
|
|
||
|
|
||
|
Electric shutter |
|
Centrifuge |
|
|
||
|
Dryer |
|
Elevator door |
|
|
||
|
|
||
|
Running machine |
|
Tooling machine |
|
|
||
|
|
||
|
Overheat |
|
|
|
|
|
|
|
|
|
Conformity to global standards
UL and cUL listed for North America
CE marked for Europe
Quality process controlled by ISO9001, ISO14000
02
Starvert iG5
Reduced size
Enhancing its performance the iG5 shows much smaller size compares to the previous model, the iG series.
Maximum 50% of total volume has been reduced in iG5 in order to mount it easily on smaller control panel and DIN rail with less weight. It allows more cost effective panel construction and system design.
Built-in communication interface and PC monitoring software
The iG5 has built-in the most popular communication interfaces such as Modbus-RTU and RS232/485. The iG5 has the small inverter features and standard medium drive features together.
The "DriveviewTM" software offers Window® based computer monitoring tool through RS485 interface with graphic capture, keypad emulator, parameter edit and text monitor. It is applicable for all LG inverters.
RS - 485
ModBus-RTUTM
Built-in PID control
It is valuable in process control. The built-in PID controller controls flow, temperature, pressure, etc. through the proportional, integral and differential calculus between the feedback value and reference value in closed loop.
Space vector PWM technology
The Space vector technology is being adopted in all LG drives. It features outstanding performance in its control characteristics. It has low total harmonic distortion, low current ripple, low torque ripple, low motor temperature rise, and better voltage utilization. It is a basic control platform of the iG5 drive. The advantages of Space vector PWM technology are being proved in many applications.
Better Efficiency (Low Iron Loss in Motor)
Low Total
Harmonic Distortion |
Low Motor Heat (Extended Motor) |
|
|
||
|
|
High Voltage Utilization (15.9%) |
Low Torque Ripple |
Low Current Ripple |
Stable & Smooth Operation |
|
|
High and StableTorque
03
Features & Selection Guide
Optimum acceleration and deceleration
To achieve a maximum torque during the acceleration and deceleration, "trip free" function is activated. The 32-bit DSP CPU monitors the current transition during the acceleration and deceleration to program an optimum curve that is under the trip-triggering level.
Stopped |
|
|
|
|
|
|
Stopped |
|
|
|
|
|
|
CH1=2V |
|
|
CH3=5V |
CH4=2V |
1s/div |
CH1=2V |
|
|
CH3=5V |
CH4=2V |
1s/div |
||
DC 10:1 |
|
|
DC 10:1 |
DC 10:1 |
[1s/div] |
DC 10:1 |
|
|
DC 10:1 |
DC 10:1 |
[1s/div] |
||
|
|
|
|
|
|
NORM:1kS/s |
|
|
|
|
|
|
NORM:1kS/s |
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Trip |
|
|
|
|
|
|
=Filter= |
=Offset= |
=Record Length= |
=Trigger= |
=Filter= |
=Offset= |
=Record Length= |
|
=Trigger= |
|||||
Smoothing : OFF |
Ch1 |
: 0.00V |
Main : |
10k |
Mode : AUTO |
Smoothing : OFF |
Ch1 |
: 0.00V |
Main : |
10k |
Mode : AUTO |
||
BW : FULL |
Ch2 |
: 0.00V |
Zoom : 500 |
Type : EDGE CH1 |
BW : FULL |
Ch2 |
: 0.00V |
Zoom : 500 |
Type : EDGE CH1 |
||||
|
CH3 : 0.00V |
|
|
Delay : 0.0ns |
|
CH3 : 0.00V |
|
|
Delay : 0.0ns |
||||
|
CH4 : 0.00V |
|
|
Hold Off : |
MINIMUM |
|
CH4 : 0.00V |
|
|
Hold Off : MINIMUM |
Traditional curve |
Optimum curve |
PNP and NPN switchable duals signals
The iG5 has both PNP and NPN signals in order to controlled by PLC or outside controller.
Regardless the type of PLC or type of control signal, iG5 can work with positive 24Vdc and negative 24Vdc.
Inverter rating selection guide
Inverter type nomenclature
|
|
SV |
|
008 |
|
iG5 |
|
-4 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LG Starvert drive
|
|
|
|
004 |
0.37kW |
|
|
|
|
|
|
008 |
0.75kW |
|
|
|
|
|
|
015 |
1.5kW |
|
|
|
|
|
|
. |
. |
|
|
|
|
|
|
220 |
22kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
iG5 |
iG5 series |
|
-1 |
1 phase 200~230V |
||||
iS5 |
iS5 series |
|
-2 |
3 phase 200~230V |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
iH |
iH series* |
|
-4 |
3 phase 380~460V |
||||
|
|
|
|
|
|
|
|
|
iV5 |
iV5 series |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
* iH drive has a different designation in kW.
04