Operating Instructions
50cm Free Standing Gas Cooker
|
|
|
|
|
|
Contents |
|
GB |
|
|
|
|
|
|
Warning,2
GB
Introduction, 3
English,1
Installation, 4-8
Gas connection Electrical connection
Adapting the cooker to different types of gas Burner and Nozzle Specifications
IT50G1 IT50G S IT50G1 S
IT50L S
IT50L
IT50G
ITL50G1
ITL50GM
ITL50GA
ITL50GW
Safety Information, 9
Features, 10
Control Panel, 11
Use of hotplates, 12
Grilling, 13
Oven, 14
Oven cooking charts, 15
Care and Cleaning, 16
Cooking Results Not Satisfactory?, 17 Something Wrong With Your Cooker?, 18 If it Still Won’t Work..., 19
Technical Characteristics, 20
Key Contacts, 24
You must read these instructions prior to using your appliance and retain them for future use.
WARNING
WARNING: The appliance and its accessible parts become hot during use. Care should be taken to avoid touching hea ng elements.
Children less than 8 years of age shall be kept away unless
con nuously supervised. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabili es or lack of experience and knowledge if they have been given supervision or instruc on concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. WARNING: Una ended cooking on a hob with fat or oil can be dangerous and may result in fire.
NEVER try to ex nguish a fire with water, but switch o the appliance and then cover flame e.g. with a lid or a fire blanket.
Do not use harsh abrasive cleaners or sharp metal scrapers to clean the oven door glass since they can scratch the surface, which may result in sha ering of the glass.
The internal surfaces of the compartment (where present) may become hot.
Never use steam cleaners or pressure cleaners on the appliance.
Remove any liquid from
the lid before opening it. Do not close the
glass cover (if present) when the gas burners or electric hotplates are s ll hot. WARNING: Ensure that the appliance is switched o before replacing the lamp to avoid the possibility of electric shock. CAUTION: the use of inappropriate hob guards can cause accidents.
! When you place the rack inside, make sure that the stop is directed upwards and in the back of the cavity.
Introduction
Your new appliance is guaranteed* and will give lasting service. This guarantee is only applicable if the appliance has been installed in accordance with the installation instructions detailed in this booklet.
To help make best use of your cooking equipment, please read this booklet carefully.
The cooker is designed specifically for domestic use and responsibility will not be accepted for use in any other installation.
! When the cooker is first used an odour may be emitted, this will cease after a period of use.
When first using the cooker ensure that the room is well ventilated (e.g. open a window or use an extractor fan) and that persons who may be sensitive to the odour avoid any fumes. It is suggested that any pets be removed from the room until the smell has ceased. This odour is due to temporary finish on oven liners and elements and also any moisture absorbed by the insulation.
* The guarantee is subject to the provisions that the |
GB |
|
appliance: |
||
|
a.Has been used solely in accordance with the Users Instruction Book.
b.Has been properly connected to a suitable supply voltage as stated on the rating plate attached to this equipment.
c.Has not been subjected to misuse or accident or been modified or repaired by any person other than the authorised employee or agent.
d.Has been correctly installed.
1.This appliance is intended for nonprofessional use within the home.
2.These instructions are only for those countries whose symbols appear in the booklet and on the serial no. plate of the appliance.
3.This owner’s manual is for a class 1 appliance (insulated) or class 2, subclass 1 appliances (installed between two cabinets.
! Keep the appliance clean, as a build up of grease or fat from cooking can cause a fire.
3
Installation
The appliance must only be installed by a
GB competent person. In the UK, CORGI registered installers undertake to work to safe and satisfactory standards.
Before moving your cooker check that it is cool, and switch off at the cooker control unit. Movement of your cooker is most easily achieved by lifting the front as follows:
Open the grill door sufficiently to allow a comfortable grip on the underside front edge of the oven roof, avoiding any grill elements.
! Take care in moving the cooker as it is heavy. Take care to ensure that any floor covering is not damaged. (see
figure)
Splashplate optional, apply to Parts Department (see Back Cover for contact number.)
The following instructions should be read by a qualified
technician to ensure that the appliance is installed, regulated and technically serviced correctly in compliance with current regulations.
! remember to unplug the appliance from the mains before regulating the appliance or carrying out any maintenance work.
Positioning
! this unit may be installed and used only in permanently ventilated rooms according to the British Standards Codes Of Practice: B.S. 6172/B.S. 5440, Par. 2 and B.S. 6891 Current Editions. The following requirements must be observed:
a.The cooker should not be installed in a bed sitting room with a volume of less than 20m3. If it is installed in a room of volume less than 5m3 an air vent of effective area of 110cm2 is required, if it is installed in a room of volume between 5m3 and 10m3 a supplementary airvent area of 50cm2 is required,
if the volume exceeds 11m3 no airvent is required. However, if the room has a door or a window which opens directly to the outside no air vent is required even when the volume is between 5m3 and 11m3.
b.During prolonged use of the appliance you may consider it necessary to open a window to the outside to improve ventilation.
c.If there are other fuel burning appliances in the same room, B.S.5440 Part 2 Current Edition, should, be consulted to determine the requisite air vent
feet in the plinth (900mm - 915mm). Adjust the feet by tilting the cooker from the side. Then install the product into position.
! This appliance must not be fitted on a platform.
The cooker is designed to fit between kitchen cabinets spaced 500mm apart. The space either side need only be sufficient to allow withdrawal of the cooker for servicing. It can be used with cabinets one side or both as well as in a corner setting. It can also be used free-standing.
Adjacent side walls which project above hob level, must not be nearer to the cooker than 150mm or 65mm (Fig. A) and should be protected by heat resistant material. Any overhanging surface or cooker hood should not be nearer than 750mm. (Fig.A)
a.The cooker may be located in a kitchen, a kitchen/ diner or bed sitting room, but not in a bathroom or shower room.
b.The hoods must be installed according to the requirements in the hood handbook.
c.The wall in contact with the back of the cooker must be of flameproof material.
d.The cooker is fitted with a safety chain that must be attached to a hook, secured to the wall behind the appliance.
!some models can have their gas connection inverted. It is important to make sure the safety chain is always situated on the side which corresponds to the hose holder (Fig. B).
Tall cupboard on the right hand side of 50cm gas cooker
65 mm min |
min |
|
400 mm min |
750 mm |
150 mm min |
|
|
Fig. A |
500 mm min |
|
|
|
||
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tall cupboard on the left hand side of 50cm gas cooker
|
min |
65 mm min |
65 mm min |
750 mm |
400 mm min |
|
|
500 mm min
Fig. B
Gas connection
The cooker should be connected to the gas-supply by a corgi registered installer. During installation of this product it is essential to fit an approved gas tap to isolate the supply from the appliance for the
convenience of any subsequent removal or servicing.
4
Connection of the appliance to the gas mains or liquid gas must be carried out according to the prescribed regulation in force, and only after it is ascertained that it is adaptable to the type of gas to be used. If not, follow the instructions indicated in the paragraph headed “Adaptation to different gas types”. On some models the gas supply can be connected on the left or on the right, as necessary; to change the connection, reverse the position of the hose holder with that of the cap
and replace the gasket (supplied with the appliance). In the case of connection to liquid gas, by tank, use pressure regulators that conform to the regulation in force. The gas supply must be connected to the left of the appliance. Be sure that the hose does not pass through the rear of the cooker touching hot parts.
! make sure the supply pressure conforms with the values shown in the table entitled “Caracteristics of the burners and nozzles”. When the cooker is installed between cabinets
(recessed), the gas connection must be effected by an approved flexible hose with bayonet fitting (BS 669 Current Edition). The gas inlet for the cookers is a threaded G 1/2 gas female fitting.
Connecting the gas supply
To make the connection, a flexible hose should be used corresponding to the current gas regulations which are:
•the hose must never be at any point in its lenght in contact with the “hot” parts of the cooker;
•the hose must never be longer than 1,5 metre;
•the hose must not be subject to any tension or torsional stress and it must not have any excessively
narrow curves or bottlenecks;
• the hose must be easy to
inspect along its entire length to
check its condition;
• the hose must always be in
good condition, never attempt
to repair.
! the installation must comply with gas safety (installation and use) regulations 1984. In all cases for the above, by low, a qualified, corgi approved engineer must be called for installation.
Electrical connection
Power supply voltage and frequency: 230-240V a.c. 50Hz.
! the supply cable must be positioned so that it never reaches at any point a temperature 50°C higher than
the room temperature. The cable must be routed away GB from the rear vents. Should you require it, you may
use a longer cable, however, you must ensure that the cable supplied with the appliance is replaced by one of the same specifications in accordance with current standards and legislation.
Your appliance is supplied with a 13 amp fused plug that can be plugged into a 13 amp socket for
immediate use. Before using the appliance please read the instructions below.
WARNING - THIS APPLIANCE MUST BE EARTHED. THE FOLLOWING OPERATIONS SHOULD BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Replacing the fuse
When replacing a faulty fuse, a 13 amp ASTA approved fuse to BS 1362 should always be used, and the fuse cover re-fitted. If the fuse cover is lost, the plug must not be used until a replacement is obtained.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of the correct colour as indicated by the coloured marking or the colour that is embossed in words on the base of the plug. Replacements can be obtained directly from your nearest Service Depot.
Removing the plug:
If your appliance has a non-rewireable moulded plug and you should wish to remove it to add a cable extension or to re-route the mains cable through partitions, units etc., please ensure that either:
•the plug is replaced by a fused 13 amp re-wireable plug bearing the BSI mark of approval.
or:
•the mains cable is wired directly into a 13 amp cable outlet, controlled by a switch, (in compliance with
BS 5733) which is accessible without moving the appliance.
Please note: for appliances with a rating greater than 13 amp (eg: electric hob, double ovens and freestanding electric cookers etc.) the mains cable must be wired into a cooker output point with a rating of 45 amp. In this case the cable is not supplied.
Disposing of the plug:
Ensure that before disposing of the plug itself, you make the pins unusable so that it cannot be accidentally inserted into a socket. Instructions for connecting cable to an alternative plug:
! the wires in the mains lead are coloured in accordance with the following code:
Green & Yellow - Earth Blue - Neutral
5
|
Brown |
- Live |
||
GB |
||||
If the colours of the wires in the mains lead do not |
||||
|
||||
|
correspond with the coloured markings identifying the |
|||
|
||||
|
terminals in your plug, proceed as follows: |
|||
|
Connect Green & Yellow wire to terminal marked “E” or |
|||
|
|
or coloured Green or Green & Yellow. |
||
|
|
|||
|
|
|||
|
|
|||
|
Connect Brown wire to terminal marked “L” or coloured |
|||
|
Red. |
|
||
|
Connect Blue wire to terminal marked “N” or coloured |
|||
|
Black. |
|
||
|
If a 13 amp plug (BS 1363) is used it must be fitted |
|||
|
with a 13 amp fuse. A 15 amp plug must be protected |
|||
|
by a 15 amp fuse, either in the plug or adaptor or at |
|||
|
the distribution board. If you are in any doubt about the |
|||
|
electrical supply to your machine, consult a qualified |
|||
|
electrician before use. |
|||
|
How to connect an alternative plug: |
|||
|
The wires in this mains lead are coloured in |
|||
|
accordance with the following code: |
|||
|
BLUE |
“NEUTRAL” (“N”) |
||
|
BROWN“LIVE” (“L”) |
|||
|
GREEN AND YELLOW “EARTH” (“E”) |
Disposing of the appliance
When disposing of the appliance please remove the plug by cutting the mains cable as close as possible to the plug body and dispose of it as described above.
|
|
Adapting the cooker to |
|
|
|
GREEN & |
|
different types of gas |
YELLOW |
|
|
|
|
|
BROWN |
13 amp fuse |
|
|
|
|
BLUE |
CROSS-BAR |
In order to adapt the cooker |
|
CORD GRIP |
to a different type of gas with |
|
|
|
|
|
respect to the gas for which it |
|
|
was produced (indicated on the |
|
|
label attached to the lid), follow |
|
|
|
|
|
these steps: |
a)replace the hose holder mounted on the appliance with that supplied in the bag of “cooker accessories”.
b)Replacing the burner nozzles on the hob:
•remove the grids and slide the burners from their housings;
•unscrew the nozzles using a 7 mm socket spanner, and replace them with nozzles for the new type of gas (see table 1 “Burner and nozzle characteristics”).
•replace all the components by repeating the steps in reverse order.
c) Minimum regulation of the hob burners:
•turn the tap to minimum;
•remove the knob and adjust the regulation screw, which is positioned in or next to the tap pin, until the
flame is small but steady.
! in the case of liquid gas, the regulation screw must be screwed in to the bottom.
• check that the flame does not turn off when you turn the tap quickly from high to low.
d) Regulating the primary air of the burners: The primary air of the burners requires no regulation.
Adapting to different types of gas
In order to adapt the oven to a different type of gas with respect to the gas for which it was manufactured (indicated on the label), follow these simple steps:
a) Replacing the oven burner nozzle
•open the oven door fully
•pull out the sliding oven bottom
Z
V V
•unscrew the two screws and take off the shield protecting the burner (in main oven burner only).
•Pry the fixing tab “V” and remove the oven burner
•Unscrew the oven burner nozzle using the socket spanner for the nozzles “Z”, or a 7 mm socket spanner, and replace it with a nozzle suited to the new type of gas (see Table 1).
Take particular care handling the spark plug wires and the thermocouple pipes.
•Replace all the parts, following the steps described above in the reverse order.
b)Minimum regulation of the gas oven burner with thermostat:
•light the burner as described in the paragraph “the oven knob” of the instruction booklet.
6
|
|
|
• turn the knob to Max for about 10 minutes and then |
GB |
|
turn the knob to the Min setting; |
||
|
•remove the knob;
•regulate the screw positioned outside the thermostat pin until the flame is small but steady.
! in the case of liquid gas, the regulation screw must be screwed in to the bottom.
•
check that the burner does not turn off when you turn the knob from Max to Min and and when you open and close the oven door quickly.
Adapting the gas grill to different types of gas
Replacing the nozzle of the grill burner:
•remove the screw and then slide out the grill burner “V” (see Figure);
•unscrew the grill burner nozzle using the special socket spanner for the nozzles (see Figure) or better still a 7mm socket spanner; replace the nozzle with
|
|
|
|
a nozzle |
|
|
|
|
for the |
|
|
|
|
new type |
|
|
|
|
of gas |
V |
|
|
|
(see table |
|
|
|
1). |
|
|
|
|
|
|
|
|
|
I |
|
|
|
|
|
|
Important
On completion of the operation, replace the old rating sticker with one indicating the new type of gas used. This sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to “regulators for channelled gas”.
7
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GB |
Burner and Nozzle Specifications |
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Liquid Gas |
|
|
|
Natural Gas |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
Burner |
Diameter |
Thermal Power |
By-Pass |
Nozzle |
|
Flow* |
Nozzle |
Flow* |
|
||||||
|
|
|
|
|
|
|
kW (p.c.s.*) |
1/100 |
1/100 |
|
|
g/h |
1/100 |
l/h |
|
|||
|
|
|
|
(mm) |
Nominal |
|
Reduced |
(mm) |
(mm) |
*** |
|
|
** |
(mm) |
|
|
||
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fast |
100 |
|
94 |
3,00 |
|
0,7 |
41 |
87 |
218 |
|
|
214 |
128 |
286 |
|
|
|
|
(Large)(R) |
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Semi Fast |
75 |
|
69 |
1,90 |
|
0,4 |
30 |
70 |
138 |
|
|
136 |
104 |
181 |
|
|
|
|
(Medium)(S) |
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Auxiliary |
51 |
|
46 |
1,00 |
|
0,4 |
30 |
52 |
73 |
|
|
71 |
76 |
95 |
|
|
|
|
(Small)(A) |
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Oven |
|
- |
2,60 |
|
0,6 |
36 |
71 |
189 |
|
|
186 |
115 |
248 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Grill |
|
- |
2,50 |
|
1,3 |
63 |
80 |
182 |
|
|
179 |
122 |
238 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Supply |
|
|
Nominal (mbar) |
|
|
28-30 |
|
37 |
20 |
|
|
||||
|
|
|
|
|
Minimum (mbar) |
|
|
20 |
|
|
25 |
17 |
|
|
||||
|
|
|
Pressures |
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
Maximum (mbar) |
|
|
35 |
|
|
45 |
25 |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*At 15°C and 1013 mbardry gas
** |
Propane |
P.C.S. = 50,37 MJ/Kg |
***Butane P.C.S. = 49,47 MJ/Kg Natural P.C.S. = 37,78 MJ/m3
S S
A R
IT50G1
IT50G S IT50G1 S
IT50L S
IT50L
IT50G
ITL50G1
ITL50GM
ITL50GA
ITL50GW
8