QuickSpecs
HP 5800 Switch Series
Models
HP 5800-24G-PoE+ Switch |
JC099A |
HP 5800-24G Switch |
JC100A |
HP 5800-24G-SFP Switch |
JC103A |
HP 5800-48G-PoE Switch |
JC104A |
HP 5800-48G Switch |
JC105A |
HP 5800-48G Switch with 2 Slots |
JC101A |
HP 5800AF-48G Switch |
JG225A |
|
|
Key features
For enterprise edge, distribution, data center
Cut-through design with low latency
Support for up to 84 ports
OAA module for flexible deployment
Redundant, hot-swappable power supplies, fans
Product overview
HP 5800 series switches offer an unmatched combination of Gigabit and 10-Gigabit Ethernet port density, high-availability architecture, and full Layer 2 and Layer 3 dual-stack IPv4 and IPv6 capabilities. In addition to wire-speed line-rate performance on all ports, the switches include patented Intelligent Resilient Framework (IRF) technology and Rapid Ring Protection Protocol (RRPP), which allow local or geographically distributed HP 5800 switches to be interconnected for higher resiliency and performance. Available in PoE and non-PoE models as well as 1 RU and 2 RU form factor configurations, HP 5800 switches are built on open standards and include an open application architecture (OAA) module slot that enables flexible deployment options for new services. These versatile switches are ideal for use in the network core of buildings or departments, or as high-performance switches in the convergence layer or network edge of enterprise campus networks.
Features and benefits
Quality of Service (QoS)
Powerful QoS feature
creates traffic classes based on access control lists (ACLs), IEEE 802.1p precedence, IP, and DSCP or Type of Service (ToS) precedence; supports filter, redirect, mirror, or remark; supports the following congestion actions: strict priority (SP) queuing, weighted round robin (WRR), weighted fair queuing (WFQ), weighted random early discard (WRED), weighted deficit round robin (WDRR), and SP+WDRR
Integrated network services
with support for open application architecture (OAA) modules, extends and integrates application capability into the network
Ring Resiliency Protection Protocol (RRPP)
provides fast recovery for ring Ethernet-based topology; provides consistent application performance for applications such as VoIP
Management
Remote configuration and management
is available through a secure Web browser or a command-line interface (CLI)
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 1 |
QuickSpecs
HP 5800 Switch Series
Overview
IEEE 802.1ab LLDP discovery
advertises and receives management information from adjacent devices on a network
USB support:
File copy
allows users to copy switch files to and from a USB flash drive
DHCP options:
DNS Relay and SMTP Redirection
DHCP: Server (RFC 2131), Client, and Option-82 Relay (RFC 3046) sFlow
provides scalable, ASIC-based network monitoring and accounting; this allows network operators to gather a variety of sophisticated network statistics and information for capacity planning and real-time network monitoring purposes
SNMPv1, v2c, and v3
facilitate centralized discovery, monitoring, and secure management of networking devices
Network Time Protocol (NTP)
synchronizes timekeeping among distributed time servers and clients; keeps consistent timekeeping among all clock-dependent devices within the network so that the devices can provide diverse applications based on the consistent time
Connectivity
High-density port connectivity
supports up to 84 1-Gigabit ports per unit (612 per stack)
Auto-MDIX
automatically adjusts for straight-through or crossover cables on all 10/100 ports
Jumbo frames
on Gigabit Ethernet and 10-Gigabit ports, jumbo frames of 9k size allow high-performance remote backup and disaster-recovery services
IEEE 802.3af Power over Ethernet (PoE)
provides up to 15.4 W per port to IEEE 802.3af-compliant PoE-powered devices such as IP phones, wireless access points, and security cameras
IEEE 802.3at Power over Ethernet (PoE+) support
simplifies deployment and dramatically reduces installation costs by helping to eliminate the time and cost involved in supplying local power at each access point location
IPv6 native support
IPv6 host
enables switches to be managed and deployed at the IPv6 network's edge
Dual stack (IPv4/IPv6)
transitions from IPv4 to IPv6, supporting connectivity for both protocols
MLD snooping
forwards IPv6 multicast traffic to the appropriate interface
IPv6 ACL/QoS
supports ACL and QoS for IPv6 network traffic, preventing traffic flooding
IPv6 routing
supports IPv6 static routes and IPv6 versions of RIP, OSPF, IS-IS, and BGP routing protocols
Performance
Hardware-based wire-speed access control lists (ACLs)
feature-rich ACL implementation (TCAM-based) helps provide high levels of security and ease of administration without impacting network performance
Unique versatile architecture
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 2 |
QuickSpecs
HP 5800 Switch Series
Overview
supports the best of both fixed-port and modular configurations
Resiliency and high availability
Data center–optimized design
the HP 5800AF-48G Switch (JG225A) supports front-to-back/back-to-front airflow for hot/cold aisles, rear rack mounts, and redundant hot-swappable AC or DC power and fans
Manageability
Full-featured console
provides complete control of the switch with a familiar command-line interface (CLI)
Web interface
allows configuration of the switch from any Web browser on the network
RMON and sFlow
provide advanced monitoring and reporting capabilities for statistics, history, alarms, and events
Multiple configuration files
allow multiple configuration files to be stored to a flash image
Troubleshooting
Ingress and egress port monitoring enable network problem solving
Traceroute and ping
enable testing of network connectivity
Virtual cable tests
provide visibility to cable problems
Layer 2 switching
GARP VLAN Registration Protocol:
allows automatic learning and dynamic assignment of VLANs
32K MAC addresses
provide access to many Layer 2 devices
4,094 port-based VLANs
provide security between workgroups
IEEE 802.1ad QinQ and Selective QinQ
increase the scalability of an Ethernet network by providing a hierarchical structure; connect multiple LANs on a high-speed campus or metro network
Gigabit Ethernet port aggregation
allows grouping of ports to increase overall data throughput to a remote device
10 GbE port aggregation
allows grouping of ports to increase overall data throughput to a remote device
Spanning Tree/MSTP, RSTP, and STP Root Guard prevent network loops
IPFIX/sFlow
allows traffic sampling
Layer 3 services
Address Resolution Protocol (ARP)
determines the MAC address of another IP host in the same subnet; supports static ARPs; gratuitous ARP allows detection of duplicate IP addresses; proxy ARP allows normal ARP operation between subnets or when subnets are separated by a Layer 2
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 3 |
QuickSpecs
HP 5800 Switch Series
Overview
network
Dynamic Host Configuration Protocol (DHCP)
simplifies the management of large IP networks and supports client and server; DHCP Relay enables DHCP operation across subnets
Layer 3 routing
Layer 3 IPv4 routing
provides routing of IPv4 at media speed; supports static routes, RIP and RIPv2, OSPF, IS-IS, and BGP
RIP and RIPng support
provides complete support of RIP for both IPv4 and IPv6
OSPF and OSPFv3 support
provides complete support of OSPF for both IPv4 and IPv6
IS-IS and IS-ISv6 support
provides complete support of IS-IS for both IPv4 and IPv6
Layer 3 IPv6 routing
provides routing of IPv6 at media speed; supports static routes, RIPng, OSPFv3, IS-ISv6, and BGP4+
Bidirectional Forwarding Detection (BFD)
enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and IRF
Virtual Router Redundancy Protocol (VRRP) and VRRP Extended allow quick failover of router ports
Policy-based routing
makes routing decisions based on policies set by the network administrator
IGMPv1, v2, and v3
allow individual hosts to be registered on a particular VLAN
PIM-SSM, PIM-DM, and PIM-SM (for IPv4 and IPv6)
support IP Multicast address management and inhibition of DoS attacks
Equal-Cost Multipath (ECMP)
enables multiple equal-cost links in a routing environment to increase link redundancy and scale bandwidth
NEW MPLS support
provides extended support of MPLS, including MPLS VPNs and MPLS Traffic Engineering (MPLS TE)
NEW VPLS support
provides extended support of VPLS for data center to data center communication at Layer 2; provides support of hierarchical VPLS for scalability
Security
Unicast Reverse Path Forwarding (URPF)
allows normal packets to be forwarded correctly, but discards the attaching packet due to lack of reverse path route or incorrect inbound interface; prevents source spoofing and distributed attacks; supports distributed UFPF
Defense-in-depth security
provides integrated and distributed security enforcement that can be managed from a central location, such as the HP Intelligent Management Center (IMC)
Advanced processor queuing mechanism
helps prevent denial-of-service (DoS) attacks, while DHCP snooping helps ensure that devices can only receive an IP address from a legitimate DHCP server on the network
IEEE 802.1X-based dynamic delivery of QoS, ACLs, and VLANs allows complete control over user network access
Guest VLAN
similar to IEEE 802.1X, it provides a browser-based environment to authenticated clients
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 4 |
QuickSpecs
HP 5800 Switch Series
Overview
Port isolation
secures and adds privacy, and prevents malicious attackers from obtaining user information
MAC-based authentication
allows or denies access to the switch based on client MAC address
IP source guard
helps prevent IP spoofing attacks
HTTPS management
provides secure Web management
Multi-Customer Edge (MCE)-Multicast Virtual Routing and Forwarding (MVRF) provide MPLS Edge router support
Public Key Infrastructure (PKI) is used to control access
RADIUS/HWTACACS
eases switch management security administration by using a password authentication server
Secure Shell (SSHv2)
encrypts all transmitted data for secure, remote CLI access over IP networks
IP Source Guard
filters packets on a per-port basis, which prevents illegal packets from being forwarded
Convergence
Voice VLAN
automatically assigns VLAN and priority for IP phones, simplifying network configuration and maintenance
Internet Group Management Protocol (IGMP)
is used by IP hosts to establish and maintain multicast groups; supports v1, v2, and v3; utilizes Any-Source Multicast (ASM) or Source-Specific Multicast (SSM) to manage IPv4 multicast networks
Protocol Independent Multicast (PIM)
is used for IPv4 and IPv6 multicast applications; supports PIM Dense Mode (DM), Sparse Mode (SM), and Source-Specific Mode (SSM)
LLDP-MED (Media Endpoint Discovery)
is a standard extension of LLDP that stores values for parameters such as QoS and VLAN to automatically configure network devices such as IP phones
Monitor and diagnostics
Port mirroring
enables traffic on a port to be simultaneously sent to a network analyzer for monitoring OAM (IEEE 802.3ah)
operational, administration and maintenance (OAM) management capabilities detects data link layer problems that occurred in the "last mile"; monitors the status of the link between the two devices
CFD (IEEE 802.1ag)
connectivity fault detection (CFD) provides a Layer 2 link OAM mechanism used for link connectivity detection and fault locating
Additional information
Intelligent Resilient Framework (IRF)
Creates virtual resilient switching fabrics, where two or more switches perform as a single Layer 2 switch and Layer 3 router
Switches do not have to be co-located and can be part of a disaster-recovery system
Servers or switches can be attached using standard LACP for automatic load balancing and high availability Simplifies network operation by eliminating the complexity of Spanning Tree Protocol, ECMP, or VRRP
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 5 |
QuickSpecs
HP 5800 Switch Series
Overview
OAA modules
support wireless network management and high-performance security applications; leverage network infrastructure investment
Green IT and power
use the latest advances in silicon development, shut off unused ports, and use variable-speed fans to improve energy efficiency
Higher scalability with IRF
HP Intelligent Resilient Framework (IRF) technology simplifies the architecture of server access networks; up to nine 5800 switches can be combined to deliver unmatched scalability of virtualized access layer switches and flatter, two-tier FlexFabric networks using IRF, which reduces cost and complexity
Warranty and support
Lifetime warranty
for as long as you own the product with advance replacement and next-business-day delivery (available in most countries)†
Electronic and telephone support
limited electronic and telephone support is available from HP; to reach our support centers, refer to: www.hp.com/networking/contact-support; for details on the duration of support provided with your product purchase, refer to: www.hp.com/networking/warrantysummary
Software releases
to find software for your product, refer to: www.hp.com/networking/support; for details on the software releases available with your product purchase, refer to: www.hp.com/networking/warrantysummary
†HP warranty includes repair or replacement of hardware for as long as you own the product, with next business day advance replacement (available in most countries). The disk drive included with HP AllianceOne Advanced Services and Services zl Modules, HP Threat Management Services zl Module, HP AllianceOne Extended zl Module with Riverbed Steelhead, HP MSM765zl Mobility Controller and HP Survivable Branch Communication zl Module powered by Microsoft Lync has a five-year hardware warranty. For details, refer to the Software license and hardware warranty statements at: www.hp.com/networking/warranty.
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 6 |
QuickSpecs
HP 5800 Switch Series
Build To Order:
BTO is a standalone unit with no integration. BTO products ship standalone are not part of a CTO or Rack-Shippable solution.
Standard Switch Chassis |
|
|
HP 5800-24G Switch |
JC100A |
|
24 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1U - Height |
|
|
C15 PDU NA |
JC100A#B2B |
|
C15 to C14 Jumper Cord (NA) |
|
|
C15 PDU ROW |
JC100A#B2C |
|
C15 to C14 Jumper Cord (ROW) |
|
|
HP 5800-24G-PoE Switch |
JC099A |
|
24 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1U - Height |
|
|
C15 PDU NA |
JC099A#B2B |
|
C15 to C14 Jumper Cord (NA) |
|
|
C15 PDU ROW |
JC099A#B2C |
|
C15 to C14 Jumper Cord (ROW) |
|
|
HP 5800-24G-SFP Switch |
JC103A |
|
24 100/1000 SFP ports |
See Configuration |
|
1 extended module slot |
Note:1, 4 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Must select min 1 Power Supply |
|
|
1U - Height |
|
|
HP 5800-48G Switch |
JC105A |
|
48 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1UHeight |
|
|
C15 PDU NA |
JC105A#B2B |
|
|
|
|
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 7 |
QuickSpecs
HP 5800 Switch Series
Configuration
C15 to C14 Jumper Cord (NA) |
|
|
|
C15 PDU ROW |
|
JC105A#B2C |
|
C15 to C14 Jumper Cord (ROW) |
|
|
|
HP 5800-48G-PoE Switch |
|
JC104A |
|
48 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
||
1 extended module slot |
Note:1, 3 |
||
4 fixed 1000/10000 SFP+ ports |
|
|
|
Power Supply included |
|
|
|
1U - Height |
|
|
|
C15 PDU NA |
|
JC104A#B2B |
|
C15 to C14 Jumper Cord (NA) |
|
|
|
C15 PDU ROW |
|
JC104A#B2C |
|
C15 to C14 Jumper Cord (ROW) |
|
|
|
HP 5800-48G Switch with 2 Slots |
JC101A |
||
48 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
||
2 extended module slot |
Note:4 |
||
4 fixed 1000 SFP ports |
|
|
|
Must select min 1 Power Supply |
|
|
|
2U - Height |
|
|
|
Configuration Rules |
|
|
|
Note 1 |
The following Transceivers install into this switch: |
|
|
|
JD092B - HP X130 SFP+ LC SR Transceiver |
|
|
|
JD093B - HP X130 SFP+ LC LRM Transceiver |
|
|
|
JD094B - HP X130 SFP+ LC LR Transceiver |
|
|
|
JD061A - HP X125 1G SFP LC LH40 1310nm Transceiver |
|
|
|
JD062A - HP X120 1G SFP LC LH40 1550nm Transceiver |
|
|
|
JD118B - HP X120 1G SFP LC SX Transceiver |
|
|
|
JD119B - HP X120 1G SFP LC LX Transceiver |
|
|
|
JD063B - HP X125 1G SFP LC LH70 Transceiver |
|
|
|
JD089B - HP X120 1G SFP RJ45 T Transceiver |
|
|
|
JD095C - HP X240 10G SFP+ SFP+ 0.65m DAC Cable |
|
|
|
JD096C - HP X240 10G SFP+ SFP+ 1.2m DAC Cable |
|
|
|
JD097C - HP X240 10G SFP+ SFP+ 3m DAC Cable |
|
|
|
JG081C - HP X240 10G SFP+ SFP+ 5m DAC Cable |
|
|
|
JC784C - HP X240 10G SFP+ 7m DAC Cable |
|
|
Note 3 |
Localization required. |
|
|
Note 4 |
The following Transceivers install into this Module: |
|
|
|
JD061A - HP X125 1G SFP LC LH40 1310nm Transceiver |
|
|
|
JD062A - HP X120 1G SFP LC LH40 1550nm Transceiver |
|
|
|
JD089B - HP X120 1G SFP RJ45 T Transceiver |
|
|
|
|
|
|
|
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 8 |
QuickSpecs
HP 5800 Switch Series
Configuration
JD118B - HP X120 1G SFP LC SX Transceiver
JD119B - HP X120 1G SFP LC LX Transceiver
JD090A - HP X110 100M SFP LC LH40 Transceiver
JD091A - HP X110 100M SFP LC LH80 Transceiver
JD102B - HP X110 100M SFP LC FX Transceiver
JD120B - HP X110 100M SFP LC LX Transceiver
JD100A - HP X115 100M SFP LC BX 10-U Transceiver
JD101A - HP X115 100M SFP LC BX 10-D Transceiver
JD063B - HP X125 1G SFP LC LH70 Transceiver
Box Level Integration CTO Models
CTO Switch Chassis
HP 5800-24G Switch-CTO |
JC100AC |
|
24 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3, 6 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1U - Height |
|
|
HP 5800-24G-PoE Switch-CTO |
JC099AC |
|
24 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3, 6 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1U - Height |
|
|
HP 5800-24G-SFP Switch-CTO |
JC103AC |
|
24 100/1000 SFP ports |
See Configuration |
|
1 extended module slot |
Note:1, 4, 5 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Must select min 1 Power Supply |
|
|
1U - Height |
|
|
HP 5800-48G Switch-CTO |
JC105AC |
|
48 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3, 6 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1UHeight |
|
|
HP 5800-48G-PoE Switch-CTO |
JC104AC |
|
48 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3, 6 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1U - Height |
|
|
|
|
|
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 9 |
QuickSpecs
HP 5800 Switch Series
Configuration
HP 5800-48G Switch with 2 Slots-CTO |
JC101AC |
48 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
2 extended module slot |
Note:4, 5 |
4 fixed 1000 SFP ports |
|
Must select min 1 Power Supply |
|
2U - Height |
|
Configuration Rules |
|
Note 1 |
The following Transceivers install into this switch: (Use #0D1 if switch is CTO) If Applicable - |
|
JD092B - HP X130 SFP+ LC SR Transceiver |
|
JD093A - HP X130 SFP+ LC LRM Transceiver |
|
JD094A - HP X130 SFP+ LC LR Transceiver |
|
JD095C - HP X240 10G SFP+ SFP+ 0.65m DAC Cable |
|
JD096C - HP X240 10G SFP+ SFP+ 1.2m DAC Cable |
|
JD097C - HP X240 10G SFP+ SFP+ 3m DAC Cable |
|
JG081C - HP X240 10G SFP+ SFP+ 5m DAC Cable |
|
JC784C - HP X240 10G SFP+ 7m DAC Cable |
|
JD061A - HP X125 1G SFP LC LH40 1310nm Transceiver |
|
JD062A - HP X120 1G SFP LC LH40 1550nm Transceiver |
|
JD118B - HP X120 1G SFP LC SX Transceiver |
|
JD119B - HP X120 1G SFP LC LX Transceiver |
|
JD063B - HP X125 1G SFP LC LH70 Transceiver |
|
JD089B - HP X120 1G SFP RJ45 T Transceiver |
Note 3 |
Localization required. |
Note 4 |
The following Transceivers install into this Module: (Use #0D1 if switch is CTO) If Applicable - |
|
JD061A - HP X125 1G SFP LC LH40 1310nm Transceiver |
|
JD062A - HP X120 1G SFP LC LH40 1550nm Transceiver |
|
JD089B - HP X120 1G SFP RJ45 T Transceiver |
|
JD118B - HP X120 1G SFP LC SX Transceiver |
|
JD119B - HP X120 1G SFP LC LX Transceiver |
|
JD090A - HP X110 100M SFP LC LH40 Transceiver |
|
JD091A - HP X110 100M SFP LC LH80 Transceiver |
|
JD102B - HP X110 100M SFP LC FX Transceiver |
|
JD120B - HP X110 100M SFP LC LX Transceiver |
|
JD100A - HP X115 100M SFP LC BX 10-U Transceiver |
|
JD101A - HP X115 100M SFP LC BX 10-D Transceiver |
|
JD063B - HP X125 1G SFP LC LH70 Transceiver |
Note 5 |
If this Switch is selected at least one of these Power Supply with #0D1 is required: |
|
JD362A - HP 5500 150WAC Power Supply |
|
JC087A - HP 5800 300W AC Power Supply |
|
JC089A - HP 5800 750W AC PoE Power Supply |
Note 6 |
If this Switch is selected, Then a Minimum of 1 factory integrated accessory must be ordered and integrated |
|
to CTO chassis. See Menu below, option must have a #0D1 to be integrated to the CTO Chassis. |
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 10 |
QuickSpecs
HP 5800 Switch Series
Configuration
Rack Level Integration CTO Models
Standard Switch Chassis
HP 5800-24G Switch |
JC100A |
|
24 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3, 6, 10 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1U - Height |
|
|
C15 PDU NA |
JC100A#B2B |
|
C15 to C14 Jumper Cord (NA) |
|
|
C15 PDU ROW |
JC100A#B2C |
|
C15 to C14 Jumper Cord (ROW) |
|
|
HP 5800-24G-PoE Switch |
JC099A |
|
24 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3, 6, 10 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1U - Height |
|
|
C15 PDU NA |
JC099A#B2B |
|
C15 to C14 Jumper Cord (NA) |
|
|
C15 PDU ROW |
JC099A#B2C |
|
C15 to C14 Jumper Cord (ROW) |
|
|
HP 5800-24G-SFP Switch |
JC103A |
|
24 100/1000 SFP ports |
See Configuration |
|
1 extended module slot |
Note:1, 4, 7, 10 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Must select min 1 Power Supply |
|
|
1U - Height |
|
|
HP 5800-48G Switch |
JC105A |
|
48 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
1 extended module slot |
Note:1, 3, 6, 10 |
|
4 fixed 1000/10000 SFP+ ports |
|
|
Power Supply included |
|
|
1UHeight |
|
|
C15 PDU NA |
JC105A#B2B |
|
C15 to C14 Jumper Cord (NA) |
|
|
|
|
|
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 11 |
QuickSpecs
HP 5800 Switch Series
Configuration
C15 PDU ROW |
JC105A#B2C |
||
|
C15 to C14 Jumper Cord (ROW) |
|
|
HP 5800-48G-PoE Switch |
JC104A |
||
|
48 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
|
1 extended module slot |
Note:1, 3, 6, 10 |
|
|
4 fixed 1000/10000 SFP+ ports |
|
|
|
Power Supply included |
|
|
|
1U - Height |
|
|
C15 PDU NA |
JC104A#B2B |
||
|
C15 to C14 Jumper Cord (NA) |
|
|
C15 PDU ROW |
JC104A#B2C |
||
|
C15 to C14 Jumper Cord (ROW) |
|
|
HP 5800-48G Switch with 2 Slots |
JC101A |
||
|
48 RJ-45 autosensing 10/100/1000 ports |
See Configuration |
|
|
2 extended module slot |
Note:4, 7, 10 |
|
|
4 fixed 1000 SFP ports |
|
|
|
Must select min 1 Power Supply |
|
|
|
2U - Height |
|
|
Cofiguration Rules: |
|
|
|
Note 1 |
The following Transceivers install into this switch: |
|
|
|
JD092B - HP X130 SFP+ LC SR Transceiver |
|
|
|
JD093B - HP X130 SFP+ LC LRM Transceiver |
|
|
|
JD094B - HP X130 SFP+ LC LR Transceiver |
|
|
|
JD061A - HP X125 1G SFP LC LH40 1310nm Transceiver |
|
|
|
JD062A - HP X120 1G SFP LC LH40 1550nm Transceiver |
|
|
|
JD118B - HP X120 1G SFP LC SX Transceiver |
|
|
|
JD119B - HP X120 1G SFP LC LX Transceiver |
|
|
|
JD063B - HP X125 1G SFP LC LH70 Transceiver |
|
|
|
JD089B - HP X120 1G SFP RJ45 T Transceiver |
|
|
|
JD095C - HP X240 10G SFP+ SFP+ 0.65m DAC Cable |
|
|
|
JD096C - HP X240 10G SFP+ SFP+ 1.2m DAC Cable |
|
|
|
JD097C - HP X240 10G SFP+ SFP+ 3m DAC Cable |
|
|
|
JG081C - HP X240 10G SFP+ SFP+ 5m DAC Cable |
|
|
|
JC784C - HP X240 10G SFP+ 7m DAC Cable |
|
|
Note 3 |
Localization required. |
|
|
Note 4 |
The following Transceivers install into this Module: |
|
|
|
JD061A - HP X125 1G SFP LC LH40 1310nm Transceiver |
|
|
|
JD062A - HP X120 1G SFP LC LH40 1550nm Transceiver |
|
|
|
JD089B - HP X120 1G SFP RJ45 T Transceiver |
|
|
|
|
|
|
|
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 12 |
QuickSpecs
HP 5800 Switch Series
Configuration
|
JD118B - HP X120 1G SFP LC SX Transceiver |
|
JD119B - HP X120 1G SFP LC LX Transceiver |
|
JD090A - HP X110 100M SFP LC LH40 Transceiver |
|
JD091A - HP X110 100M SFP LC LH80 Transceiver |
|
JD102B - HP X110 100M SFP LC FX Transceiver |
|
JD120B - HP X110 100M SFP LC LX Transceiver |
|
JD100A - HP X115 100M SFP LC BX 10-U Transceiver |
|
JD101A - HP X115 100M SFP LC BX 10-D Transceiver |
|
JD063B - HP X125 1G SFP LC LH70 Transceiver |
Note 6 |
If HP CTO Switch Chassis is selected to be Rack Level Integration (No C Sku), Then #B2B, |
|
or #B2C is Required on the Switch Chassis. (Optional when Switch is not Factory Racked. |
|
See Drop down remark in "Power Supplies" section.) |
Note 7 |
If HP CTO Switch Chassis is selected to be Rack Level Integration (No C Sku), Then #B2B, |
|
or #B2C is Required on the Power Supply's. (Optional when Switch is not Factory Racked. |
|
See Drop down remark in "Power Supplies" section.) |
Note 10 |
If HP CTO Switch Chassis is selected to be Rack Level Integration, Then the Switch needs |
|
to integrate (with #0D1) to the HP Universal Rack. |
Internal Power Supplies
(JC103x and JG256x Only) System (std 0 // max 2) User Selection (min 1 // max 2) per switch |
|
|
(JC101x and JG242x Only) System (std 0 // max 2) User Selection (min 1 // max 2) per switch |
|
|
HP 5500 150WAC Power Supply |
JD362A |
|
|
See Configuration |
|
|
Note:1, 2, 3, 5 |
|
C15 PDU NA |
JD362A#B2B |
|
C15 to C14 Jumper Cord (NA) |
|
|
C15 PDU ROW |
JD362A#B2C |
|
C15 to C14 Jumper Cord (ROW) |
|
|
HP 5500 150WDC Power Supply |
JD366A |
|
|
See Configuration |
|
|
Note:1, 3 |
|
HP 5800 300W AC Power Supply |
JC087A |
|
|
See Configuration |
|
|
Note:1, 2, 4, 5 |
|
C15 PDU NA |
JC087A#B2B |
|
C15 to C14 Jumper Cord (NA) |
|
|
|
|
|
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 13 |
QuickSpecs
HP 5800 Switch Series
Configuration
C15 PDU ROW |
|
JC087A#B2C |
C15 to C14 Jumper Cord (ROW) |
|
|
HP 5800 300W DC Power Supply |
JC090A |
|
|
|
See Configuration |
|
|
Note:1, 4 |
HP 5800 750W AC PoE Power Supply |
JC089A |
|
|
|
See Configuration |
|
|
Note:1, 2, 4, 5 |
C15 PDU NA |
|
JC089A#B2B |
C15 to C14 Jumper Cord (NA) |
|
|
C15 PDU ROW |
|
JC089A#B2C |
C15 to C14 Jumper Cord (ROW) |
|
|
Cofiguration Rules: |
|
|
Note 1 |
If 2 power supplies are selected Then they must be the same Sku number. |
|
Note 2 |
Localization required on orders without #B2B or #B2C options. |
|
Note 3 |
This power supply only supported on JC103x and JG256x Only. |
|
Note 4 |
This power supply only supported on JC101x and JG242x Only. |
|
Remarks: |
|
|
Drop down under power supply should offer the following options and results: Switch to PDU Power Cord - replace localized option with #B2B in AMS or #B2C in APJ and EMEA
Switch to Wall Power Cord - Should leave existing Localized Option (no #B2x options)
Enter the following menu selections as integrated to the CTO Model X server above if order is factory built.
Modules
Ethernet Modules
(JC101x, JG242x, Switch Only ) System (std 0 // max 2) User Selection (min 0 // max 2) per chassis |
|
(JC100x, JC099x, JC103x, JC105x, JC104x, JG254x, JG255x, JG256x, JG257x, JG258x, Switch Only ) |
|
System (std 0 // max 1) User Selection (min 0 // max 1) per chassis |
|
HP 5800 16-port SFP Module |
JC095A |
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 14 |
QuickSpecs
HP 5800 Switch Series
Configuration
|
min=0 \ max=16 SFP Transceivers |
See Configuration |
|
|
Note:2 |
HP 5800 4-port 10GbE SFP+ Module |
JC091A |
|
|
min=0 \ max=4 SFP and SFP + Transceivers |
See Configuration |
|
|
Note:1 |
HP 5800 2-port 10GbE SFP+ Module |
JC092B |
|
|
min=0 \ max=2 SFP and SFP + Transceivers |
See Configuration |
|
|
Note:1 |
HP 5800 16-port Gig-T Module |
JC094A |
|
|
No Transceivers |
|
Cofiguration Rules: |
|
|
Note 1 |
The following Transceivers install into this Module: (Use #0D1 if switch is CTO) If |
|
|
Applicable - |
|
|
JD092B - HP X130 10G SFP+ LC SR Transceiver |
|
|
JD093B - HP X130 10G SFP+ LC LRM Transceiver |
|
|
JD094B - HP X130 10G SFP+ LC LR Transceiver |
|
|
JD095C - HP X240 10G SFP+ SFP+ 0.65m DAC Cable |
|
|
JD096C - HP X240 10G SFP+ SFP+ 1.2m DAC Cable |
|
|
JD097C - HP X240 10G SFP+ SFP+ 3m DAC Cable |
|
|
JG081C - HP X240 10G SFP+ SFP+ 5m DAC Cable |
|
|
JC784C - HP X240 10G SFP+ 7m DAC Cable |
|
|
JD061A - HP X125 1G SFP LC LH40 1310nm Transceiver |
|
|
JD062A - HP X120 1G SFP LC LH40 1550nm Transceiver |
|
|
JD089B - HP X120 1G SFP RJ45 T Transceiver |
|
|
JD118B - HP X120 1G SFP LC SX Transceiver |
|
|
JD119B - HP X120 1G SFP LC LX Transceiver |
|
Note 2 |
The following Transceivers install into this Module: (Use #0D1 if switch is CTO) If |
|
|
Applicable - |
|
|
JD061A - HP X125 1G SFP LC LH40 1310nm Transceiver |
|
|
JD062A - HP X120 1G SFP LC LH40 1550nm Transceiver |
|
|
JD089B - HP X120 1G SFP RJ45 T Transceiver |
|
|
JD118B - HP X120 1G SFP LC SX Transceiver |
|
|
JD119B - HP X120 1G SFP LC LX Transceiver |
|
|
JD090A - HP X110 100M SFP LC LH40 Transceiver |
|
|
JD091A - HP X110 100M SFP LC LH80 Transceiver |
|
|
JD102B - HP X110 100M SFP LC FX Transceiver |
|
|
JD120B - HP X110 100M SFP LC LX Transceiver |
|
|
JD100A - HP X115 100M SFP LC BX 10-U Transceiver |
|
|
JD101A - HP X115 100M SFP LC BX 10-D Transceiver |
|
Access Control Modules
(JC101x and JG242x Switch Only ) System (std 0 // max 1) User Selection (min 0 // max 1) per chassis
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 15 |
QuickSpecs
HP 5800 Switch Series
Configuration
HP 5800 ACM for 32-64 Aps |
|
JD443A |
|
No Transceivers |
|
|
|
HP 5800 ACM for 64-256 Aps |
JD441A |
||
No Transceivers |
|
See Configuration |
|
|
|
Note:1 |
|
HP 5820 VPN Firewall Module |
JD255A |
||
No Transceivers |
|
See Configuration |
|
|
|
Note:1 |
|
Cofiguration Rules: |
|
|
|
Note 1 |
This Module install to the following switches only: |
|
|
|
JC101x - HP 5800-48G Switch with 2 Slots |
|
|
PoE Modules |
|
|
|
(JC101x and JG242x Switch Only ) System (std 0 // max 1) User Selection (min 0 // max 1) per chassis |
|
|
|
HP 5800 PoE Module |
|
JC097B |
|
No Transceivers |
|
|
|
Transceivers |
|
|
|
SFP+ Transceivers |
|
|
|
HP X130 10G SFP+ LC SR Transceiver |
JD092B |
||
HP X130 10G SFP+ LC LRM Transceiver |
JD093B |
||
HP X130 10G SFP+ LC LR Transceiver |
JD094B |
||
HP X240 10G SFP+ SFP+ 0.65m DAC Cable |
JD095C |
||
HP X240 10G SFP+ SFP+ 1.2m DAC Cable |
JD096C |
||
HP X240 10G SFP+ SFP+ 3m DAC Cable |
JD097C |
||
HP X240 10G SFP+ SFP+ 5m DAC Cable |
JG081C |
||
HP X240 10G SFP+ 7m DAC Cable |
JC784C |
||
SFP Transceivers |
|
|
|
|
|
|
|
|
DA - 13807 Worldwide — Version 12 — March 25, 2013 |
Page 16 |