This literature was published years prior to the establishment of Agilent Technologies as a company independent from Hewlett-Packard and describes products or services now available through Agilent. It may also refer to products/services no longer supported by Agilent. We regret any inconvenience caused by obsolete information. For the latest information on Agilent’s test and measurement products go to:

www.agilent.com/find/products

Or in the U.S., call Agilent Technologies at 1-800-452-4844 (8am–8pm EST)

HP 8903B Audio Analyzer

HP 8903E Distortion Analyzer

20 Hz to 100 kHz

Technical Specifications

All parameters describe performance in automatic operation or properly set manual conditions. Specifications describe the instrument’s warranted performance. Supplemental characteristics (shown in italics) are intended to provide information useful in applying the instrument by giving typical, but non-warranted, performance parameters.

The versatile choice for audio analysis

Related Literature:

Product Overview

..... 5968-1388E

Price List ................

5968-1389EUS

HP 8903B System Specifications

(HP 8903B only, source and analyzer combined)

Distortion

Residual Distortion and Noise (the higher of): 80 kHz BW: 80 dB or 17 µ V, 20 Hz to 20 kHz.

500 kHz BW: 70 dB or 50 µ V, 20 Hz to 50 kHz.

65 dB or 50 µ V, 50 kHz to 100 kHz.

Flatness

Supplemental Characteristics

Supplemental Characteristics

Typical residual distortion and noise of the source and analyzer combined (source voltage set to 1.5 V, 80 kHz BW). Dashed line represents typical residual distortion and noise for the analyzer only.

Typical flatness of source and analyzer combined (source voltage set to 1 V, 1 kHz reference).

Signal-to-Noise

Frequency Range: 50 Hz to 100 kHz

Display Range: 0 to 99.99 dB

Accuracy: ±1 dB

Input Voltage Range: 50 mV to 300 V

Residual Noise (the higher of): 80 kHz BW: 85 dB or 17 µ V

500 kHz BW: 70 dB or 50 µ V

Supplemental Characteristics

Time to Return First Measurement: <2.5 second

Measurement Rate: One reading per second

Resolution: Same as listed under SINAD, on page 2

HP 8903B Source Specifications

(HP 8903B only)

Frequency

Range: 20 Hz to 100 kHz

Resolution: 0.3%

Accuracy: 0.3% of setting

Output Level

Range: 0.6 mV to 6 V open circuit

Resolution: 0.3% or better

Accuracy:

2% of setting 60 mV to 6 V, 20 Hz to 50 kHz. 3% of setting 6 mV to 6 V, 20 Hz to 100 kHz.

5% of setting 0.6 mV to 6 mV, 20 kHz to 100 kHz.

Flatness (1 kHz reference):

±0.7% (±0.06 dB), 20 Hz to 20 kHz. ±2.5% (±0.22 dB), 20 Hz to 100 kHz.

Distortion and Noise (the higher of):

80 kHz BW: 80 dB or 15 µ V, 20 Hz to 20 kHz. 500 kHz BW: 70 dB or 38 µ V, 20 Hz to 50 kHz.

65 dB or 38 µ V, 50 kHz to 100 kHz.

Impedance: 600 Ω ±1% or 50 Ω ±2% front panel or HP-IB programmable (47 special function).

Supplemental Characteristics

Frequency Switching Speed: <3 ms (does not include HP-IB programming time)

Output Level Switching Speed: 20 ms (does not include HP-IB programming time)

Sweep Mode: Log sweep with up to 500 points per decade or 255 points total between entered start and stop frequencies.

Time to Return First Measurement: 1.5 s

Measurement Rate: Two readings per second

SINAD

Fundamental Frequency Range: 20 Hz to 100 kHz

Display Range: 0 to 99.99 dB

Residual Distortion and Noise: Same as listed under distortion

Accuracy:

±1 dB, 20 Hz to 20 kHz. ±2 dB, 20 kHz to 100 kHz.

Input Voltage Range: 50 mV to 300 V

Supplemental Characteristics

Detection: True-rms or rms-calibrated average

Resolution:

HP 8903B: 0.01 dB for SINAD ratios >25 dB. For ratios <25 dB the display is rounded to the nearest 0.5 dB to reduce digit flickering of noisy signals

(full resolution is available via special function 16.1).

HP 8903E: Powers up with special function 16.1 active for 0.01 dB resolution at all SINAD ratios.

Analog Meter (HP 8903B only): Active in SINAD mode only and for SINAD ratios up to 18 dB (24 dB using special function 7.1).

1.0 dB typical accuracy.

Tuning:

HP 8903B: Notch filter is tuned to the internal audio source frequency.

HP 8903E: Notch filter is tuned to the counted input frequency.

Time to Return First Measurement: 1.5 s

Measurement Rate: Two readings per second

HP 8903B and HP 8903E

Analyzer Specifications

Distortion

Fundamental Frequency Range: 20 Hz to 100 kHz

Display Range: 0.001% to 100% (99.99 to 0 dB)

Accuracy:

±1 dB, 20 Hz to 20 kHz. ±2 dB, 20 kHz to 100 kHz.

Input Voltage Range: 50 mV to 300 V

Residual Distortion and Noise (the higher of): 80 kHz BW: 80 dB or 15 µ V, 20 Hz to 20 kHz. 500 kHz BW: 70 dB or 45 µ V, 20 Hz to 50 kHz.

65 dB or 45 µ V, 50 kHz to 100 kHz.

 

Supplemental Characteristics

 

3 dB Measurement Bandwidth: 10 Hz to 500 kHz

 

Detection: True rms or rms-calibrated average

 

Displayed Resolution:

 

0.0001% (<0.1% distortion).

 

0.001% (0.1% to 3% distortion).

 

0.01% (3% to 30% distortion).

 

0.1% (>30% distortion).

2

AC Level

Full Range Display: 300.0 V, 30.00 V, 3.000 V, 0.3000 V, 30.00 mV, 3.000 mV, 0.3000 mV.

Overrange: 33%, except on 300 V range

Accuracy: (rms and average detection) ±2%, 50 mV to 300 V, 20 Hz to 20 kHz. ±3%, 0.3 mV to 50 mV, 20 Hz to 100 kHz. ±5%, 50 mV to 300 V, 20 kHz to 100 kHz.

Supplemental Characteristics

AC Converter: True-rms responding for signals with crest factor up to 3, rms calibrated average detection, or quasi-peak detection.

Time to Return First Measurement: <1.5 s

Measurement Rate: >2.5 readings per second

3 dB Measurement Bandwidth: >500 kHz

Quasi-Peak Detector Characteristic: Meets CCIR 468-4

Quasi-Peak Detector Accuracy: (20 Hz to 20 kHz) ±6% typically

HP 8903B and HP 8903E Analyzer Specifications cont.

DC Level

Full Range Display: 300.0 V, 48.00 V, 16.00 V, 4.000 V.

Overrange: 33%, except on 300 V range

Accuracy: ±1.0% of reading (600 mV to 300 V). ±6 mV (Vin <600 mV).

Supplemental Characteristics

Time to Return First Measurement: <1.5 s

Measurement Rate: Three readings per second

Frequency Measurement

Measurement Range: 20 Hz to 150 kHz. (20 Hz to 100 kHz in distortion and SINAD modes.)

Resolution: Five digits (0.01 Hz for input frequencies <100 Hz).

Accuracy: ±(0.004% plus one digit).

Sensitivity: 50 mV in distortion and SINAD modes. 5 mV in AC-level and signal-to-noise (HP 8903B only) modes.

Supplemental Characteristics

Measurement Rate: Same as measurement mode selected

Counting Technique: Reciprocal with 2 MHz timebase

Plug-In Audio Filters

400 Hz High-Pass Filter

3 dB Cutoff Frequency: 400 kHz ±40 Hz.

Roll-off: Seventh-order Butterworth; 42 dB per octave or 140 dB per decade

CCITT Weighting Filter (CCITT rec. P53) Deviation from Ideal Response:

±0.2 dB at 800 Hz.

±1.0 dB, at 300 Hz to 3 kHz. ±2.0 dB, at 50 Hz to 3.5 kHz. ±3.0 dB, at 3.5 kHz to 5 kHz.

Standard Audio Filters

30 kHz Low-Pass Filter

3 dB Cutoff Frequency: 30 kHz ±2 kHz.

Roll-off: Third-order Butterworth; 18 dB per octave or 60 dB per decade

80 kHz Low-Pass Filter

3 dB Cutoff Frequency: 80 kHz ±4 kHz.

Roll-off: Third-order Butterworth; 18 dB per octave or 60 dB per decade

CCIR Weighting Filter (CCIR rec. 468-2) Deviation from Ideal Response:

±0.1 dB at 6.3 kHz.

±0.2 dB, at 6.3 kHz to 7.1 kHz. ±0.4 dB, at 7.1 kHz to 10 kHz. ±0.5 dB, at 200 Hz to 6.3 kHz.

±1.0 dB, at 31.5 Hz to 200 Hz, 10 kHz to 20 kHz. ±2.0 dB, at 20 kHz to 31.5 kHz.

C-Message Weighting Filter (per BSTM 41004) Deviation from Ideal Response:

±0.1 dB at 1 kHz

±1.0 dB, 60 Hz to 5 kHz

3

Plug-In Audio Filters cont.

CCIR/ARM Weighting Filter (CCIR rec. 468-2, averageresponding meter, Dolby Labs Bulletin No. 19/4)

Deviation from Ideal Response: Same as listed previously under CCIR Weighting Filter.

"A" Weighting Filter (IEC rec. 179 and ANSI S1.4, type one sound-level meter)

Deviation from Ideal Response:

±0.1 dB at 1 kHz.

±0.5 dB, 20 Hz to 10 kHz. ±1.0 dB, at 10 kHz to 20 kHz.

HP 8903B and HP 8903E

General Specifications

HP 8903B Rear Panel Features

HP-IB Connector

Monitor Output: Provides a scaled output of the input signal. In SINAD, distortion, and distortion-level modes, the fundamental is removed.

Front/Rear Panel Outputs

Monitor Output: Output impedance 600 Ω .

AC-level mode: provides scaled output of input signal.

SINAD, distortion, and distortion-level modes: provide a scaled output of the input signal with the fundamental removed.

HP 8903E Rear Panel Features

HP-IB Connector

Analyzer Input

Input Type: Balanced (full differential).

Input Impedance: 100 kΩ ±1% shunted by <300 pF, each side to ground. (In dc-level mode the input resistance is 101 kΩ ±1%).

Maximum Input: Maximum peak input voltage, any combination of ac and dc:

HP 8903B: 425 volts peak, applied differentially or between either input and ground.

HP 8903E: 42 volts peak, low side to ground. 425 volts peak, differentially or high side to ground.

CMRR: >60 dB, 20 Hz to 1 kHz, Vin <2 V. >45 dB, 20 Hz to 1 kHz.

>30 dB, 20 Hz to 20 kHz.

Supplemental Characteristics

Typical CMRR: From 20 Hz to 100 kHz with input voltage of 6 volts.

General

Temperature: Operating, 0 °C to 55 °C: storage, 55 °C to 75 °C.

Remote Operation: HP-IB. All functions except the line switch, low-terminal ground switches, and the ´10and ÷ 10increment keys (HP 8903B only), are remotely controllable. The HP 8903E has many special functions which can only be accessed via HP-IB commands.

HP-IB Compatibility: SH1, AH1, T5, TE0, L3, LE0, SR1, RL1, PP0, DC1, DT1, C0, E1.

Power: 100, 120, 220, or 240 V (+5, 10%); 48 to 66 Hz. 100 or 120 V (+5, 10%); 48 to 440 Hz. 100 VA maximum.

Weight:

HP 8903B: Net 12.3 kg. (27 lb.); shipping 16.4 kg. (36 lb.) HP 8903E: Net 11.8 kg. (26 lb.); shipping 15.9 kg. (35 lb.)

Dimensions: 146 mm H ´ 425 mm W ´ 462 mm D. (5.75 ´ 16.8 ´ 18.2 in.)

HP System II Size: 5.25 H ´ 1 MW ´ 17 D.

EMI: Radiated interference is within the requirements of RE02 of MIL STD 461B and FTZ 526/527.

Conducted and Radiated Susceptibility: Meets the requirements of methods CS01, CS02, and RS03 (1 V/meter) of MIL STD 461B dated 1980.

Warranty Information

This Hewlett-Packard instrument product is warranted against defects in material and workmanship for a period of one year from date of shipment. During the warranty period, Hewlett-Packard Company will at its option, either repair or replace products which prove to be defective.

For warranty service or repair, this product must be returned to a service facility designated by HP. Buyer shall prepay shipping charges to HP and HP shall pay shipping charges, duties, and taxes for products returned to HP from another country.

HP warrants that its software and firmware designated by HP for use with an instrument will execute its programming instructions when properly installed on that instrument. HP does not warrant that the operation of the instrument, or software, or firmware will be uninterrupted or error free.

Limitation Of Warranty

The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by buyer, buyer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or improper site preparation or maintenance. No other warranty is expressed or implied. HewlettPackard specifically disclaims the implied warranties of merchantability and fitness for a particular purpose.

ã 1982 Hewlett-Packard Co.

Data subject to change Printed in U.S.A. 8/98 5968-1390E

Errata

Title & Document Type:

Manual Part Number:

Revision Date:

HP References in this Manual

This manual may contain references to HP or Hewlett-Packard. Please note that HewlettPackard's former test and measurement, semiconductor products and chemical analysis businesses are now part of Agilent Technologies. We have made no changes to this manual copy. The HP XXXX referred to in this document is now the Agilent XXXX. For example, model number HP8648A is now model number Agilent 8648A.

About this Manual

We’ve added this manual to the Agilent website in an effort to help you support your product. This manual provides the best information we could find. It may be incomplete or contain dated information, and the scan quality may not be ideal. If we find a better copy in the future, we will add it to the Agilent website.

Support for Your Product

Agilent no longer sells or supports this product. You will find any other available product information on the Agilent Test & Measurement website:

www.tm.agilent.com

Search for the model number of this product, and the resulting product page will guide you to any available information. Our service centers may be able to perform calibration if no repair parts are needed, but no other support from Agilent is available.

HP 8903a, 8903e schematic
Loading...
+ 125 hidden pages