Honeywell HUT-102 User Manual

0 (0)

HUT-102_OM_Rev0.qxd 3/17/05 4:04 PM Page 1

IMPORTANT SAFETY INSTRUCTIONS

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

1.Read all instructions before using this humidifier.

2.Always place this humidifier on a firm, flat and level surface. This humidifier may not work properly on an uneven surface.

3.Place this humidifier in an area where it is not accessible to children.

4.Do not place the humidifier near any heat sources such as stoves, radiators, and heaters.

5.Do not use the humidifier outdoors.

6.Before using the humidifier, check the power cord for any signs of damage. If the cord is found to be damaged, DO NOT USE and return the humidifier to the manufacturer under the warranty agreement for repair.

7.This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit securely in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.

8.To disconnect the humidifier, first turn controls to the OFF position, then grip the plug and pull it from the wall outlet. Never pull by the cord.

ULTRASONIC HUMIDIFIER

Model HUT-102 Series

9.A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.

10.The humidifier should always be unplugged and emptied when not in operation or while being serviced or cleaned.

11.Never tilt or attempt to move the humidifier while it is operating or filled with water. UNPLUG the humidifier before moving.

12.This humidifier requires regular cleaning. Refer to the CLEANING instructions provided. Never clean the humidifier in any manner other than as instructed in this manual.

13.Do not direct moisture flow directly at individuals, walls or furniture.

14.When a humidifier is used in a closed room or small rooms, check periodically for proper ventilation, as excessive humidity can cause condensation stains on walls.

15.Turn the humidifier OFF if you notice moisture on the inside of your windows. For proper humidity reading use a hygrometer, which is available in many hardware and department stores, or by ordering one from the manufacturer.

16.Do not touch the nebulizer while the unit is plugged in as burns could result.

17.SAVE THESE

INSTRUCTIONS

The Honeywell trademark is used by Kaz, Inc. under license from Honeywell Intellectual Properties, Inc.

HUT-102_OM_Rev0.qxd 3/17/05 4:04 PM Page 2

Honeywell HUT-102 User Manual

HUT-102_OM_Rev0.qxd 3/17/05 4:04 PM Page 3

Introduction

H O W D O E S I T W O R K ?

SILENT ULTRASONIC TECHNOLOGY:

Water is atomized by ultrasonic sound waves and propelled in the air by a small fan. These ultrasonic pulses are silent and produce visible mist.

Your humidifier is made up of these parts:

Mist Nozzle

Tank Handle

Water Tank

Illuminated

Water Window

Water Valve

Indicator Light

Power Switch

Mist Intensity

Tank Cap

Demineralization

Cartridge

Air Outlet

Ultrasonic Nebulizer

Power Cord

Base

Set-Up

NOTE: We recommend that the humidifier be disinfected prior to first use. Please see CLEANING.

Select a firm, level, flat location - at least six inches (15 cm) from any wall for proper air flow. Place the humidifier on a water-resistant surface, as water can damage furniture and some flooring.

Kaz will not accept responsibility for property damage caused by water spillage.

3

HUT-102_OM_Rev0.qxd 3/17/05 4:04 PM Page 4

Filling

• Remove the Water Tank by grasping handle and pulling straight up (Fig. 1). Fig. 1 Set aside.

Turn the Water Tank upside down so that the Tank Cap is facing up; unscrew the Tank Cap by turning it counter-clockwise and set aside.

• Fill the Water Tank with clean, cool, tap water (Fig. 2).

• Replace the Tank Cap by firmly turning clockwise

. Turn the Water

 

Tank upright and check the Tank Cap for leaks. If any water drips from the

 

Tank Cap, remove it and re-tighten. Use of very cold water may

 

temporarily reduce the mist output. Never fill the humidifier with hot or

Fig. 2

warm water as this could cause damage and void your warranty.

 

NOTE: When carrying the filled Water Tank, please use the handle and place your other hand under the tank for additional support.

Position the Water Tank in the humidifier and push into place. Some water will empty into the Base.

• Once the filled tank has been positioned, do not attempt to move the humidifier. If it has to be moved, unplug the humidifier and remove the Water Tank first.

Operation

P O W E R

CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.

• With the power switch in the OFF position, plug the filled humidifier into a

Fig. 3

 

polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE

 

 

 

OUTLET; it will only fit one way.

 

 

1.

Turn the Power Switch clockwise

to the on position. The Water

 

 

Window will illuminate.

 

 

2.

Set your desired output by turning the knob clockwise. To operate on

 

 

HIGH, turn the dial to the end (

) (Fig. 3).

 

3.Mist will not appear immediately; allow a few minutes for the water to fill the reservoir. If you are using the optional Demineralization Cartridge, it may take up to 15 minutes for the filtering material to become saturated and for mist to appear.

4.The unit will shut off when it is out of water.

5.Turn the humidifier off before removing and refilling the Water Tank. When the Water Tank is empty the mist will stop although the fan will continue to operate.

4

HUT-102_OM_Rev0.qxd 3/17/05 4:04 PM Page 5

Demineralization Cartridge (Model DC-102)

Your humidifier comes with a Demineralization Cartridge that removes minerals from the water. This prevents the precipitation of minerals ("white dust") that can occur in hard water areas. The Demineralization Cartridge is designed to last for about a month to two months of normal use; the effective time will vary depending on the mineral content of the water used. If you live in a hard water area, we recommend the use of distilled water for better results from the humidifier.

If you are using distilled water in the humidifier, you may find the Demineralization Cartridge unnecessary. And, if you choose, you may operate the humidifier without it.

About "White Dust":

Use of high-mineral-content water will cause a white mineral residue to accumulate on room surfaces near the humidifier. The mineral residue is commonly called "white dust". The higher the mineral content (the harder your water is), the greater the potential for white dust. The white dust is not caused by a defect in the humidifier, but is due only to minerals suspended in the water.

Care and Cleaning

CAUTION: ALWAYS TURN OFF THE POWER SWITCH AND DISCONNECT THE POWER CORD FROM THE ELECTRICAL OUTLET BEFORE CLEANING.

Daily Maintenance:

1.Lift the Water Tank from the Base and empty all water from the reservoir. Remove the Tank Cap and drain any water from the Water Tank. Wipe it clean with a soft, damp cloth. Rinse the Water Tank with lukewarm water after each use.

2.DO NOT immerse the Base in water. Gently wipe the reservoir with a soft, clean, wet cloth.

3.DO NOT use detergent to clean any water-containing parts of the humidifier. Detergents and the film they leave behind can affect the output of the humidifier. DO NOT use abrasive cleansers or brushes.

4.DO NOT leave water in the Water Tank or reservoir when the unit is not in use as it may result in the buildup of mineral deposits and bacteria that can inhibit the output efficiency of the humidifier. Please note that if water remains in the Water Tank for more than a day or two, bacteria growth is possible.

Weekly Maintenance:

1.Thoroughly clean humidifier every week using a solution of bleach and water (one teaspoon of bleach in one gallon of water). Fill the Water Tank partially with this solution, let stand twenty (20) minutes, shaking vigorously every few minutes. Drain and rinse with clean water until the bleach smell is gone.

2.Wipe the reservoir with a soft cloth dampened in the solution. Rinse area thoroughly before proceeding.

3.If mineral deposits are evident around the Nebulizer, clean the surface with a soft, clean cloth and a small amount of undiluted white vinegar. If necessary for removal of mineral deposits, mix a solution of 50% white vinegar and 50% water and fill the Base with enough solution to cover the Nebulizer. Rinse out the reservoir and wipe clean. DO NOT touch Nebulizer with bare fingers as any fingerprints or other residue can affect mist output.

4.All surfaces should be thoroughly cleaned with water prior to reuse.

5

Loading...
+ 11 hidden pages