SUPPLEMENT TO INSTRUCTIONS MANUAL —

Model LT1 Warewasher, ML-104239

Model SR24C Warewasher, ML-130021, ML-27872

Model SR24H Warewasher, ML-130022, ML-27873

CHEMICAL SENSING DEVICE

SAVE THESE INSTRUCTIONS

GENERAL

The Chemical Sensing Device senses the presence of liquid chemical in a tube as it passes through a sensor. This device is standard on model LT1 and SR24C warewashers built after January 1, 2005, and is an option on model SR24H warewashers built after January 1, 2005.

OPERATION

CHEMICAL SENSING DEVICE (Fig. 1)

HOLD TO

 

 

Operate the chemical dispensing pumps (refer to

ENABLE / DISABLE

FLASHING – NO CHEMICAL

 

 

machine operating manual) to make sure that chemical

 

 

 

ON - CHEMICAL

 

 

OFF – DISABLED

 

liquid is present in the tubing going through the sensors

 

 

 

DETERGENT

 

 

in the device. LED indicator lights come on

 

 

 

 

 

 

continuously when machine comes on to indicate that

RINSE AID

 

LED's

liquid chemical is present in the tube(s).

 

 

 

 

 

A flashing indicator light and a periodic audible alarm

SANITIZER

 

 

indicate that liquid chemical has been depleted and

 

 

needs to be replenished.

 

 

 

Keep sufficient chemical supplies on hand to replenish

Fig. 1

as necessary.

If one or more chemicals are not going to be used, the system can be set so that the related sensor is disabled. To disable the sensor, press the appropriate button until the light goes off. To reactivate a disabled sensor, make sure liquid chemical is present in the tubing and press the appropriate button again until the light turns on.

To Recalibrate Sensors

If the Chemical Sensing Device does not indicate the presence or absence of liquid chemical properly, it may be necessary to recalibrate the sensor by disabling and then reactivating the sensor. To disable the sensor, press the appropriate button until the light goes off. To reactivate a disabled sensor, make sure liquid chemical is present in the tubing and press the appropriate button again until the light turns on. If sensor is enabled while tube is empty, device may not operate properly. If the Chemical Sensing Device does not indicate the presence or absence of liquid chemical properly, contact your local Hobart Service office.

Supplement to FORMS:

18500 Rev.A,

35309 Rev.A