FEATURES:

Operating Profile

Softener will remove hardness to less than 1/2 gpg when operated in accordance with the operating instructions. The system includes two tanks. This duplex configuration operates with one tank on-line during service. During regeneration cycles, one tank will provide water to service and to the regenerating tank. A water meter initiates system regeneration. The water meter measures the processed volume and is adjustable. Service flow is up-flow and regeneration flow is down-flow.

Regeneration Control Valve

The regeneration control valve is top mounted (top of media tank), and manufactured from non-corrosive materials. Control valve does not weigh more than four pounds. Control valve provides service and regeneration control for two media tanks. Inlet and outlet ports accept a quick connect, double o-ring sealed adapter. Interconnection between tanks are made through the regeneration valve with a quick connect adapter.

Control valve operates using a minimum inlet pressure of 15 psi. Pressure is used to drive all valve functions. No electric hookup is required. Control valve incorporates four operational cycles including; service, brine draw, slow rinse, and a combined fast rinse and brine refill. Service cycle operates in an up-flow direction. The brine cycle flows down-flow, opposite the service flow, providing a countercurrent regeneration. Control valve contains a fixed orifice eductor nozzle and self-adjusting backwash flow control. The control valve will prevent the bypass of hard water to service during the regeneration cycle.

Brine System

A combination salt storage and brine production tank is manufactured of corrosion resistant, plastic. The brine tank has a chamber to house the brine valve assembly. The brine float assembly allows for adjustable salt settings and provides for a shut-off to the brine refill. The brine tank includes a safety overflow connection to be plumbed to a suitable drain.

Salt Alarm

Salt alarm consists of an alarm box and a brine sensor. Brine sensor is mounted internally on the grid plate and operates on the specific gravity of proper brine concentration. An alarm condition is triggered when the concentration falls below acceptable level for more than 15 minutes. The alarm is both an 80-db audible alarm every 3 seconds and a red LED flash every 7 seconds. The alarm box operates on three AA batteries and connects to the brine sensor with a standard 2-wire phone cord

(7' phone cord supplied).

MODEL:

Model WS-40

Specifications, Details and Dimensions on Back.

Media Tanks

The tanks are designed for a maximum working pressure of 125 psi and hydrostatically tested at 300 psi. Tanks are made of engineered plastic with a 2.5 in. threaded top opening. Each tank is NSF approved. Upper distribution system is of a slot design. Lower distribution system is of a flat plate design. Distributors will provide even flow of regeneration water and the collection of processed water.

Conditioning Media

Each softener will include uniform bead cation resin having a minimum exchange capacity of 30,000 grains/ft³ when regenerated with 15.0 lbs/ft³. The media is solid, of a proper particle size and contains no plates, shells, agglomerates or other shapes, which might interfere with the normal function of the water softener.

Model WS-40

Salt Alarm

<![if ! IE]>

<![endif]>40-WS - SYSTEMS SOFTENING WATER

F-20244 – Water Softening Systems – WS-40

Page of 2

Hobart WS-40 General Manual

WATER SOFTENING SYSTEMS – WS-40

701 S Ridge Avenue, Troy, OH 45374

1-888-4HOBART • www.hobartservice.com

System Components

Media Vessel (qty) Size .............................................................

 

 

(2) 6 x 13”

 

 

 

 

 

 

 

 

Media Vessel Construction ........

Fiberglass Wrapped Engineered Plastic

 

 

 

 

 

 

 

 

Empty Bed Volume ........................................................................

 

 

0.16 ft3

 

 

 

 

 

 

 

 

Media Type ....................................................

 

 

Uniform Bead Cation Resin

 

 

 

 

 

 

 

 

Media Volume ...............................................................................

 

 

0.16 ft3

 

 

 

 

 

 

 

 

Bed Depth ....................................................................................

 

 

 

Packed

 

 

 

 

 

 

 

 

Free Board ......................................................................................

 

 

 

None

 

 

 

 

 

 

 

 

Riser Tube ...................................................................................

 

 

 

1” CPVC

 

 

 

 

 

 

 

 

Distributor

Upper ........

0.012” Slots, Engineered Plastic Basket

 

 

 

 

 

1.75"

 

 

 

Lower ..........

0.009” Slots, Stainless Steel Flat Plate

 

 

 

 

 

 

 

Under bedding .................................................................................

 

 

None

 

 

 

 

 

 

 

 

Regeneration Control ..........................................

 

Non-electric Use Meter

 

 

 

 

 

 

 

 

Regeneration Type ............................................................

 

Countercurrent

 

 

 

 

 

 

 

 

Meter Type ................................

 

0.30 - 25.00 gpm Polypropylene Turbine

 

 

 

 

 

 

 

 

Inlet Water Quality

 

 

 

 

 

 

 

 

 

 

 

Pressure Range .......................................

15 – 125 psi Dynamic Pressure

 

 

 

 

 

 

 

 

Temperature Range ...............................................................

 

 

35 – 160o F

 

 

 

 

 

 

 

 

Temperature (Continuous) .............................................................

 

 

150o F

 

 

 

 

 

 

 

 

pH Range ..................................................................................

 

 

 

5 – 10 SU

 

 

 

 

 

 

 

 

Free Chlorine Cl2 (Max.) ..............................................................

 

 

2.0 mg/l

 

 

 

 

 

 

 

 

Hardness as CaCO3 (Max.) ...........................................................

 

 

30 gpg

 

 

 

 

 

 

 

 

Operating Specs

 

 

 

 

 

 

 

 

 

 

 

Flow Range (15 / 30 psig) .................................................

 

9.1 – 15.2 gpm

 

 

 

 

 

 

 

21"

Flow Configuration ..................................................................

 

 

Alternating

 

 

 

 

 

 

 

Dimensions (width x depth x height) ...................................

14 x 14 x 22”

 

 

 

 

 

 

 

 

Weight (Operating / Shipping) ...............................................

 

 

110 / 60 lbs.

 

 

 

 

 

 

 

 

Connections

 

 

 

 

 

 

 

 

 

 

 

Inlet / Outlet Connections ..........................

 

Custom Adapter and Bracket

 

 

 

 

 

 

 

 

Drain Connection ..................................................................

 

 

0.375” Tube

 

 

 

 

 

 

 

 

Brine Line Connection ............................................

 

0.375” Tube (internal)

 

 

 

 

 

 

 

 

Overflow Connection .............................................................

 

 

0.375” Tube

 

 

 

 

 

 

 

 

Power ...............................................................................................

 

 

 

None

 

 

 

 

 

 

 

 

Salt Alarm...........................................................................

 

 

3 AA Batteries

 

 

 

 

 

 

 

 

System Part Numbers

 

 

 

 

 

 

 

 

 

 

 

WS-40, Compact Cabinet Softener ......................................

 

913091-123

 

 

 

 

 

 

 

 

Brine Tank Options

 

 

 

 

14"

 

 

 

14"

 

 

Tank Description ...................................................................

 

 

206 Cabinet

 

 

 

 

 

 

 

 

Tank Height .........................................................................................

 

 

 

22”

 

 

 

 

 

 

 

 

Tank Footprint .............................................................................

 

 

14 x 14”

 

 

 

 

 

 

 

 

Material ...........................................................................................

 

 

 

HDPE

 

 

 

 

 

 

 

 

Salt Capacity

..................................................................................

 

 

40 lbs.

 

 

 

 

 

 

 

 

Regeneration Specifications

 

 

 

 

 

 

 

 

 

 

Regeneration Volume .................................................................

 

 

5 gallons

 

 

 

 

 

 

 

 

Regeneration Time ..................................................................

 

 

11 minutes

 

 

 

 

 

 

 

 

Backwash Flow Control ............................................................

 

 

0.70 gpm

 

 

 

 

 

 

 

 

Brine Refill Flow Control ............................................................

 

 

0.20 gpm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disc Selection

 

 

 

 

 

 

 

 

 

 

 

(Compensated Hardness*)

 

 

Setting

Capacity

Efficiency

Dosing

Meter Disc

1

2

3

4

5

6

7

8

1.0 lbs.

2,527 grains

2,527 gr./lb.

5.5 lbs./ft3

4

8

11

15

19

23

27

30

 

 

 

Gallons/Regeneration:

583

282

194

146

117

97

83

73

 

 

Flow during regeneration (@ 15 psig):

9.1

9.1

9.1

9.1

8.4

6.6

5.4

4.4

 

 

 

 

 

*Compensated hardness in gpg = Hardness + (3 x Fe in mg/l)

 