Haier ADH160H1ERG, ADH140H1ERG, ADH125M1ERG, ADH125H1ERG, ADH105M1ERG User Manual

...
0 (0)

DUCT TYPE AIR CONDITIONER

OPERATION MANUAL AND INSTALLATION MANUAL

ADH071M1ERG

 

ADH071M3ERG

 

ADH090M1ERG

Contents

ADH105M1ERG

ADH125M1ERG

ADH140M1ERG

ADH105H1ERG

ADH125H1ERG

ADH140H1ERG

ADH160H1ERG

No. 0150519050

Cautions

3

Safety Precautions

4

Parts and Functions

7

Heating Mode

8

Care and Maintenance

9

Troubleshooting

10

Accessories

12

Precaution for Installation

13

Is The Unit Installed Correctly

14

Installation Procedure

15

This product must only be installed or serviced by qualified personnel. Please read this manual carefully before installation.

Keep this operation manual for future reference.

English

Original instructions

Haier Industrial Park,Qianwangang Road,Eco-Tech Development Zone,Qingdao 266555,Shandong,P.R.C.

DISPOSAL REQUIREMENTS:

Your air conditioning product is marked with this symbol.This means that electrical and electronic

products shall not be mixed with unsorted

household waste.Do not try to dismantle the system yourself:the dismantling of the air

conditioning system,treatment of the refrigerant,of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation.Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery.By ensuring this product is disposed of correctly,you will help to prevent potential negative consequences for the environment and human health.Please contact the installer or local authority for more information. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.

IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED

Contains fluorinated greenhouse gases

 

covered by the Kyoto Protocol

 

A

 

 

R410A

kg

B

 

 

 

kg

C

 

 

 

kg

D

 

 

This product contains fluorinated greenhouse gases covered by the Kyoto Protocol.Do not vent into the atmosphere. Refrigerant type:R410A

GWP:2088

GWP=global warming potential Please fill in with indelible ink,

1the factory refrigerant charge of the product

2the additional refrigerant amount charged in the field and

1+2 the total refrigerant charge

on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port(e.g.onto the inside of the stop value cover).

A contains fluorinated greenhouse gases covered by the Kyoto Protocol

B factory refrigerant charge of the product:see unit name plate

C additional refrigerant amount charged in the field D total refrigerant charge

E outdoor unit

F refrigerant cylinder and manifold for charging

WARNING

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

The appliances are not intended to be operated by means of an external timer or separate remote-control system. Keep the appliance and its cord out of reach of children less than 8 years.

The A-weighted sound pressure level is below 70 dB.

This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons

Air conditioner working temperature: cooling 10~43 degree, heating -15~24 degree.

2

Cautions

Disposal of the old air conditioner

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

Disposal of the packaging of your new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

Safety Instructions and Warnings

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

3

Safety Precautions

Before starting to use the system, read carefully this "SAFETY PRECAUTIONS" to ensure a proper operation of the system.

Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown in the column of " WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions are shown in the column of " CAUTION", a very serious problem could occur depending on situation. Make sure to observe these safety precautions faithfully because they are very important information to ensure the safety.

Symbols which appear frequently in the text have following meanings.

Strictly prohibited.

 

Observe instructions faithfully.

 

Provide a positive grounding.

 

 

 

 

 

When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make sure to hand over this manual to the new operator.

CAUTIONS FOR INSTALLATION

WARNING

The system should be applied to places as office, restaurant, residence and the like.

Application to inferior environment such as an engineering shop, could cause equipment malfunction and serious injury or death.

The system should be installed by your dealer or a professional installer.

Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.

When you need some optional devices such as a humidifier, electric heater, etc., be sure to use the products which are recommended by us. These devices should be attached by a professional installer.

Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.

CAUTION

Do not install nearby the place where may have

Depending on the place of installation, a circuit

Drain pipe should be arranged to provide a positive

leakage of flammable gas.

breaker may be necessary.

draining.

 

ON

 

 

OFF

 

If the gas leaks and gathers around, it may cause

Unless the circuit breaker is installed, it could cause

If the pipe is arranged improperly, furniture or the

the fire.

electrical shocks.

likes may be damaged by leaked water.

Where strong winds may prevail, the system

Install on the place where can endure the weight

Make sure the system is grounded.

should be fixed securely to prevent a collapse.

of air conditioner.

 

Bodily injury could result by a collapse.

Bodily injury could result by a careless installation.

Grounding cable should never be connected to

 

 

a gas pipe, city water pipe, lightning conductor

 

 

rod or grounding cable of telephone. If the

 

 

grounding cable is not set properly, it could cause

 

 

electric shocks.

CAUTIONS FOR TRANSFER OR REPAIR

WARNING

Modification of the system is strictly prohibited. When the system needs a repair, consult your dealer.

Improper practice of repair could cause water leakage, electric shock or fire.

When the air conditioner is relocated, contact your dealer or a professional installer.

Improper practice of installation could cause water leakage, electric shock or fire.

4

Haier ADH160H1ERG, ADH140H1ERG, ADH125M1ERG, ADH125H1ERG, ADH105M1ERG User Manual

Safety Precautions

CAUTIONS FOR OPERATION

WARNING

You should refrain from exposing your body directly to cool wind for a long time.

It could affect your physical condition or cause some health problems.

Do not poke the air inlet or outlet with a bar, etc.

Since the internal fan is operating with a high speed, it could cause an injury.

When any abnormal condition (scorching smell or others) is found, stop the operation immediately and turn off the power switch. Then consult your dealer.

If you continue the operation without removing the cause, it could result in a trouble, electric shock or fire.

CAUTION

The system should never be used for any other

Do not handle switches with a wet hand.

Combustion apparatus should not be placed

purposes than intended such as for preservation

 

allowing a direct exposure to wind of air conditioner.

of food, flora and fauna, precision devices or work

 

 

of art.

 

 

It could cause deterioration of food or other

It could cause electric shocks.

Incomplete combustion could occur on the

problems.

 

apparatus.

Do not wash the air conditioner with water.

Do not install the system where the air outlet

Make sure to use a fuse of proper electric rating.

 

reaches directly the flora and fauna.

 

It could cause electric shocks.

It will not be good for their health.

Use of steel or copper wire in place of a fuse is

 

 

strictly prohibited because it could result in a trouble

 

 

or fire accident.

Neither stand on the air conditioner nor place something on it.

There are risks of falling or injury by collapsed object.

It is strictly prohibited to place a container of combustible gas or liquid near the air conditioner or to spray it directly with the gas or liquid.

It could cause a fire accident.

Do not operate the system while the air outlet grill is removed.

There is a risk of injury.

Do not use the power switch to turn on or off the system.

ON

Do not touch the air outlet section while the swing louver is operating.

Do not use such equipment as a water heater, etc. around the indoor unit or the wire controller.

OFF

It could cause a fire or water leakage.

There is a risk of injury.

If the system is operated at the vicinity of such equipment which generates steam, condensed water may drip during cooling operation or it could cause a fault current or short-circuit.

When operating the system simultaneously with

Check occasionally the support structure of the

When cleaning the system, stop the operation and

a combustion apparatus, indoor air must be

unit for any damage after a use of long period of

turn off the power switch.

ventilated frequently.

time.

 

Insufficient ventilation could cause an oxygen

If the structure is not repaired immediately, the

Cleaning should never be done while the internal

deficiency accident.

unit could topple down to cause a personal injury.

fans are running with high speed.

Do not put water containers on the unit such as a flower vase, etc.

If the water enters into the unit and damages the electric insulation material, it may cause electric shock.

5

Safety Precautions

The machine is adaptive in following situation 1. Applicable ambient temperature range:

 

 

Indoor temperature

max. DB/WB

32/23 C

 

Cooling

min. DB/WB

18/14 C

 

 

 

Outdoor temperature

max. DB/WB

43/26 C

 

 

 

 

min. DB/WB

10/6 C

 

 

Indoor temperature

max. DB/WB

27 C

 

 

min. DB/WB

15 C

 

 

 

 

Heating

Outdoor temperature

max. DB/WB

24/18 C

 

 

min. DB/WB

-15 C

 

 

 

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse on the indoor PC board is broken please change it with the type of T 3.15A /250V(For ADH105,

ADH125,ADH140M1ERG);or the type T5A /250V(For ADH071M1ERG,ADH071M3ERG,ADH090M1ERG).T8A/250V(For ADH105/125/140/160H1ERG)

4.The wiring method should be in line with the local wiring standard.

5.The power cable should be:

H05RN-F 3G 4.0mm2 (outdoor unit 1UH071/090/105N1ERG), or H05RN-F 3G 6.0mm2 (outdoor unit 1UH125/140/160P1ERG), or H05RN-F 5G 4.0mm2 (outdoor unit 1UH125/140P1EK);

The connecting cable should be:

H05RN-F4G 2.5mm2;

All the cables shall have got the European authentication certificate. During installation, when the connecting cables break off, it must be assured that the grounding wire is the last one to be broken off.

6.The power cable and connect cable should be self-provided.

7.The breaker of the air conditioner should be all-pole switch, and the distance between its two contacts should be no less than 3mm.

8.The indoor unit installation height is at least 2.5m.

9.A leakage breaker must be installed.

10.

10.1 FOR ADH071M1ERG, ADH090M1ERG, we can get the 4 different ESP through adjust the indoor unit PCB SW1-4 and SW1-5, please refer below:

 

 

 

 

SW1

 

 

 

Static pressure

 

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

 

 

 

 

 

 

 

 

 

-

-

-

OFF OFF

-

-

-

10 Pa

 

-

-

-

OFF ON

-

-

-

30 Pa

 

-

-

-

ON

OFF

-

-

-

50 Pa

-

-

-

ON

ON

-

-

-

70 Pa

Attention:

Cut off the power supply to adjust the SW1-4, and SW1-5, or else the operation is invalid.

10.2 For ADH071M3ERG, ADH105M1ERG, ADH125M1ERG, ADH140M1ERG, ADH105H1ERG, ADH125H1ERG, ADH140H1ERG,ADH160H1ERG,static pressure selection need achieved by wired controller, refer wired controller's manual to get details

 

 

 

External

static pressure (pa)

 

 

 

ADH105M1ERG

ADH105H1ERG

 

Static pressure level ( N)

 

ADH125H1ERG

 

ADH071M3ERG

ADH125M1ERG

 

ADH140H1ERG

 

 

 

ADH140M1ERG

 

 

 

ADH160H1ERG

 

 

 

 

 

1

25

30

 

40

 

2

37

40

 

50

 

3

50

50

 

60

 

4

70

60

 

80

5

90

70

 

100

 

6

100

80

 

120

 

7

110

90

 

150

 

8

120

100

 

180

9

130

110

 

200

 

10

150

120

 

250

For AD105/125/140M1ERG,ADH071M3ERG,ADH105/125/140/160H1ERG,static pressure level selection can also be achieved by Infrared remote controller,method is:

Step a: set the Infrared remote controller at condition:FAN mode,fan speed high.

Step b:then aim the remote controller at the infrared remote receiver RE-02,press HEALTH button 4+N times(1N 10,integer) within 12 seconds,then the receiver will beep N+1 times,the static pressure level N is been set successfully.

Note:For Infrared remote controller YR-HBS01, need press ON/OFF button make the controller's at OFF status first,then open the button cover press FRESH button will enter FAN mode interface.

6

Parts and Functions

ADH071M1ERG ADH071M3ERG ADH090M1ERG

Electrical components Case

Air outlet frame

 

Evaporator

The pump

 

Drain pan

drain opening

ADH105M1ERG

ADH125M1ERG

ADH140M1ERG

 

Air outlet frame

 

 

 

 

 

Electrical components Case

Drain pan

 

 

 

 

Evaporator

The pump

 

 

 

 

drain opening

ADH105H1ERG

ADH125H1ERG

ADH140H1ERG

ADH160H1ERG

Air outlet frame

Drain pan

Fan

The drain opening

 

Electrical components Case

7

Heating Mode

"HOT KEEP" function

"HOT KEEP" is operated in the following cases.

When heating is started:

In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode.

Defrosting operation (in the heating mode):

When it is liable to frost, the heating operation is stopped automatically for 5 to 12 minutes once per approx. one hour, and defrosting is operated. After defrosting is completed, operation mode is automatically changed to ordinary heating operation.

When the room thermostat is actuated:

When room temperature increases and room temperature controller actuates, the fan speed is automatically changed to stop under low temperature condition of indoor heat exchanger. When room temperature decreases, air conditioner automatically changes over to ordinary heating operation.

Warming operation

Heat pump type warming

With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space, is utilized.

Defrosting operation

When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat exchanger of outdoor unit along with the drop of indoor temperature. Since the accumulated frost reduces the effect of warming, it is necessary to automatically switch the operation to the defrosting mode. During the defrosting operation, heating operation is interrupted.

Atmospheric temperature and warming capacity

Warming capacity of heat pump type air conditioner decreases along with the drop of outdoor temperature. When the warming capacity is not sufficient, it is recommended to use another heating implement.

Period of warm-up

Since the heat pump type air conditioner employs a method to circulate warm winds to warm the entire space of a room, it takes time before the room temperature rises.

It is recommendable to start the operation a little earlier in a very cold morning.

8

Loading...
+ 16 hidden pages