Haier 1U09BS1ERA, 1U12BS1ERA, 1U24GS1ERA, HUM24HC03-R2, 1U07BS1ERA INSTALLATION

...
5 (1)

ROOM AIR CONDITIONER

INSTALLATION MANUAL

1U07BS1ERA

1U09BS1ERA

1U12BS1ERA

HUM07HC03/R2(DB)

HUM09HC03/R2(DB)

HUM12HC03/R2(DB)

1U18FS1ERA

HUM18HC03/R2(DB)

1U24GS1ERA

HUM24HC03/R2(DB)

Contents

Indoor/Outdoor Unit

Installion Drawings

Safety Precautions

Read Before Installation

Installation Procedure

Outdoor Unit

Troubleshooting

●Please read this manual carefully before installtion.

Keep this operation manual for future reference.

1

2

6

9

14

NO.0010535386

Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China

EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS

CE

All the products are in conformity with the following European provision:

-Low Voltage Directive 73/23/EEC

-Low Voltage Directive 2006/95/EC

-Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC

ROHS

The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive)

WEEE

In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products.

DISPOSAL REQUIREMENTS:

Your air conditioning product is marked with this symbol.This means that electrical and electronic

products shall not be mixed with unsorted

household waste. Do not try to dismantle the system yourself : the dismantling of the air

conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and nationl legislation.

IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED

Contains fluorinated greenhouse gases

 

covered by the Kyoto Protocol

 

A

R410A

1=

kg

B

2

1

2=

kg

C

 

 

 

 

 

 

 

 

 

1+2=

kg

D

 

 

 

 

F

E

 

 

 

This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere. Refrigerant type:R410A

GWP* value:1975

GWP=global warming potential

Please fill in with indelible ink,

1 the factory refrigerant charge of the product

2 the additional refrigerant amount charged in the field and

1+2 the total refrigerant charge

on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover).

A contains fluorinated greenhouse gases covered by the Kyoto Protocol

B factory refrigerant charge of the product: see unit name plate

C additional refrigerant amount charged in the field D total refrigerant charge

E outdoor unit

F refrigerant cylinder and manifold for charging

Indoor/Outdoor Unit Installation Drawings

The models adopt HFC free refrigerant R410A.

For installation of the indoor units,refer to the installation manual which was provided with the units. (The diagram shows a wall-mounted indoor unit.)

more than 15cm

more than 10cm

Arrangement of piping directions

 

Rear left

Left

Rear

 

right

Right

Below

more than 20cm

The marks from A to G in the figure are the parts numbers.

The distance between the indoor unit and the floor should be more than 2m.

more than 60cm

Attention must be paid to the rising up of drain hose

G

more than 10cm

F

A

C

more than 20cm

D

E

Optional parts for piping

A

Non-adhesive tape

B

Adhesive tape

C Saddle (L.S) with screws

D

Connecting electric cable

for indoor and outdoor

E

Drain hose

F

Heating insulating material

G Piping hole cover

Fixing of outdoor unit

Fix the unit to concrete or block with bolts (10mm) and nuts firmly and horizontally.

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind. If vibration may affect the

house, fix the unit by attaching a vibration-proof mat.

more than 25cm

AIR OUTLET

AIR INLET

CONNECTING PIPING AND ELECTRICAL WIRING

4 DRAIN HOSE

Compressor(Inside of Unit)

The above indoor and outdoor units’ picture is just for your reference.

Please be subject to the actual product purchased.

1

Haier 1U09BS1ERA, 1U12BS1ERA, 1U24GS1ERA, HUM24HC03-R2, 1U07BS1ERA INSTALLATION

WARNING

CAUTION

2

Safety Precautions

WARNING

Have the unit professionally installed.

Be sure to carefully follow each step in this handbook when

Improper installation by an unqualified person may result

installing the unit.

in water leak, electric shock, or fire.

Improper installation may result in water leak, electric shock,

 

smoke or fire.

Place the unit on a stable, level surface that withstands the

 

weight of the unit to prevent the unit from tipping over or

Have all electrical work performed by a licensed electrician

falling causing injury as a result.

according to the local regulations and the instructions given

 

in this manual. Secure a circuit designated exclusively to

Only use specified cables for wiring. Securely connect each

the unit.

cable, and make sure that the cables are not straining the

Improper installation or a lack of circuit capacity may cause

terminals.

the unit to malfunction or present a risk of electric shock,

Cables not connected securely and properly may generate

smoke,and fire.

heat and cause fire.

 

 

Securely attach the terminal cover(panel) on the unit.

Take necessary safety measures against typhoons and

If installed improperly, dust and/or water may enter the unit

earthquakes to prevent the unit from falling over.

and present a risk of electric shock, smoke or fire.

Do not make any changes or modifications to the unit. In

Only use refrigerant R410A as indicated on the unit when

case of problems, consult the dealer.

installing or relocating the unit.

If repairs are not made properly, the unit may leak water

The use of any other refrigerant or an introduction of air into

and present a risk of electric shock, or it may produce smoke

the unit circuit may cause the unit to run an abnormal cycle

or cause fire.

and abnormal cycle and cause the unit to burst.

 

 

WARNING

Do not touch the fins on the heat exchanger with bare hands, for they are sharp and dangerous.

In the event of a refrigerant gas leak, provide adequate ventilation to the room.

If leaked refrigerant gas is exposed to a heat source, noxious gases may form.

With All-Fresh type air conditioners, outdoor air may be directly blown into the room upon thermo off. Take this into consideration when installing the unit.

Direct exposure to outdoor air may present a health hazard, and it may also cause food items to deteriorate.

Do not try to defeat the safety features of the devices, and do not change the settings.

Defeating the safety features on the unit such as the pressure switch and temperature switch or using parts other than the dealer or specialist may result in fire or explosion.

When installing the unit in a small room, safeguard against hypoxia that results from leaked refrigerant reaching the threshold level.

Consult the dealer for necessary measures to take.

When relocating the air conditioner, consult the dealer or a specialist.

Improper installation may result in water leak, electric shock, or fire.

After completing the service work, check for a refrigerant gas leak.

If leaked gas refrigerant is exposed to a heat source such as fan heater,stove,and electric grill, noxious gases may form.

Only use specified parts.

Have the unit professionally installed. Improper installation may cause water leak, electric shock,smoke, or fire.

3