Fluke 189, 187 Technical Data

4.3 (3)
Fluke 189, 187 Technical Data

Page 1 of 3, Document #2153

187/189 Extended Specifications

©2000 Fluke Corporation

Rev. A-8/00

Fluke 187/189

True-rms Digital Multimeter

Extended Specifications

Nominal Specifications

Function

Ranges/Description

DC Voltage

0 to 1000V

DC Current

0 to 10A (20A for 30 seconds)

AC Voltage, True-rms

2.5 mV to 1000V - 100 kHz bandwidth

AC Current, True-rms

25 A to 10A (20A for 30 seconds)

Resistance

0 to 500 Mohms

Conductance

0 to 500 Nanosiemens

Capacitance

0.001 nF to 50 mF

Diode Test

3.1V

Temperature

-200°C to 1350° C (-328° F to 2462° F)

Frequency

0.5 Hz to 1000 kHz

Accuracy (Basic DC V)

0.025%

(Basic AC V)

0.4%

Features

Feature

Description

Dual Displays

50,000 count primary display

 

5,000 count secondary display

Backlight with 2

Bright white backlight for clear readings

brightness selections

in poorly lighted areas

Fast Autorange

Meter automatically selects best range -

 

instantly

AC+DC True RMS, ac

Choices for AC only, AC and DC dual

rms specified to 100 kHz

display, or AC+DC readings

dBm, dBV

User selectable impedance references

 

for dBm

AutoHOLD

Holds readings on display

Continuity/Open Test

Beeper sounds for Ohms readings below

 

threshold or for momentary

 

open circuit indication

Fast Bar Graph

51 Segments for peaking and nulling

Duty Cycle/Pulse Width

Measure time a signal is on or off in %

 

or milliseconds

MIN MAX/Fast MIN MAX

Record Maximum, Minimum, and Average

with elapsed and

values. Real Time for MAX or MIN, elapsed

Real Time Stamp

time for AVG.

 

Fast MIN MAX captures peaks to 250 sec.

Closed Case Calibration

No internal adjustments needed

Battery/Fuse

Battery or fuse replacement without

Access Door

voiding calibration

Hi-Impact Overmold Case

Integrated Protective Holster provides

 

superior impact protection for your meter

1For the 5,000 count mode, divide the number of least significant digits (counts) by 10.

2A residual reading of 8 to 180 digits with leads shorted, will not affect stated accuracy above 5% of range.

320 counts in dual display DC or AC + DC

410A continuous up to 35°C, less than 10 minutes 35° to 55°. 20A overload for 30 seconds maximum

5See AC conversion notes for AC mV and V.

Above specifications are subject to change without notice.

Detailed Specifications

Accuracy is specified for a period of one year after calibration, at 18° C to 28°C (64°F to 82°F) with relative humidity to 90%. Accuracy specifications are given as ± ([% of reading] + [number of least significant digits])

 

 

 

 

 

Accuracy

 

 

 

 

 

45 Hz-

20 Hz-

1 kHz-

10 kHz-

20 kHz-

Function

Range

Resolution

1 kHz

45 Hz

10 kHz

20 kHz

100 kHz

AC mV 1,2

50,000mV

0.001mV

0.4% + 40

2% + 80

5% + 40

5.5% + 40

15% + 40

 

500.00 mV

0.01 mV

0.4% + 40

2% + 80

5% + 40

5.5% + 40

8% + 40

 

3000.0 mV

0.1 mV

0.4% + 40

2% + 80

0.4% + 40

1.5% + 40

8% + 40

AC V 1,2

5.0000V

0.0001V

0.4% + 40

2% + 80

0.4% + 40

1.5% + 40

8% + 40

 

50.000V

0.001V

0.4% + 40

2% + 80

0.4% + 40

1.5% + 40

8% + 40

 

500.00V

0.01V

0.4% + 40

2% + 80

0.4% + 40

Not specified

Not specified

 

1000.0V

0.1V

0.4% + 40

2% + 80

0.4% + 40

Not specified

Not specified

dBV

-56 to -6

0.01 dB

0.1 dB

0.2 dB

0.5 dB

0.5 dB

1.4 dB

 

-6 to +34

0.01 dB

0.1 dB

0.2 dB

0.1 dB

0.2 dB

0.8 dB

 

+34 to +60

0.01 dB

0.1 dB

0.2 dB

0.1 dB

Not specified

Not specified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accuracy

 

 

 

 

 

 

 

45 Hz-

20 Hz-

 

1 kHz-

 

20 kHz-

Function

Range

Resolution

1 kHz

 

45 Hz

 

20 kHz

 

100 kHz

AC A

500.00 A

0.01 A

0.75%

+ 20

1% + 20

 

0.75% + 20

 

6% + 40

 

5000.0 A

0.1 A

0.75%

+ 5

1% + 5

 

0.75% + 10

 

2% + 40

AC mA

50.000 mA

0.001 mA

0.75%

+ 20

1% + 20

 

0.75% + 20

 

9% + 40

 

400.00 mA

0.01 mA

0.75%

+ 5

1% + 5

 

1.5% + 10

 

4% + 40

AC A

5.0000A

0.0001A

1.5% + 20

1.5% + 20

 

6% + 40

 

Not specified

 

10.000A4

0.001A

1.5% + 5

1.5% + 5

 

5% + 10

 

Not specified

 

 

 

 

 

 

 

 

 

 

 

Accuracy

 

Accuracy Dual Display AC or AC+DC5

 

 

 

 

 

 

20 Hz-

45 Hz-

 

1kHz-

Function

Range

Resolution

DC

 

 

45 Hz

1 kHz

 

20 kHz

DC mV

50.000 mV

0.001mV

0.1% +20

 

2%

+ 80

0.5% + 40

 

6% + 40

 

500.00 mV

0.01 mV

0.03% + 2

 

2%

+ 80

0.5% + 40

 

 

 

 

 

 

3000.0 mV

0.1 mV

0.025% + 5

 

2%

+ 80

0.5% + 40

 

 

DC V

5.0000V

0.0001V

0.025% + 103

 

2%

+ 80

0.5% + 40

 

2% + 40

 

50.000V

0.001V

0.03%

+ 33

 

2%

+ 80

0.5% + 40

 

 

 

500.00V

0.01V

0.1% + 23

 

2%

+ 80

0.5% + 40

 

Not specified

 

1000.0V

0.1V

0.1% + 23

 

2%

+ 80

0.5% + 40

 

Not specified

DC A

500.00 A

0.01 A

0.25%

+ 20

 

1%

+ 20

1% + 20

 

 

2% + 40

 

5.000 A

0.1 A

0.25%

+ 2

 

1%

+ 10

0.75% + 10

2% + 40

DC mA

50.000 mA

0.001 mA

0.15% + 10

 

1%

+ 20

0.75% + 20

2% + 40

 

400.00 mA

0.01 mA

0.15% + 2

 

1%

+ 10

1% + 10

 

 

3% + 40

DC A

5.0000A

0.0001A

0.5% + 10

 

2%

+ 20

2% + 20

 

 

6% + 40

 

10.000A4

0.001A

0.5% + 2

 

1.5% + 10

1.5% + 10

 

5% + 40

Loading...
+ 2 hidden pages