Page 1 of 3, Document #2153
187/189 Extended Specifications
©2000 Fluke Corporation
Rev. A-8/00
Fluke 187/189
True-rms Digital Multimeter
Extended Specifications
Nominal Specifications
Function |
Ranges/Description |
DC Voltage |
0 to 1000V |
DC Current |
0 to 10A (20A for 30 seconds) |
AC Voltage, True-rms |
2.5 mV to 1000V - 100 kHz bandwidth |
AC Current, True-rms |
25 A to 10A (20A for 30 seconds) |
Resistance |
0 to 500 Mohms |
Conductance |
0 to 500 Nanosiemens |
Capacitance |
0.001 nF to 50 mF |
Diode Test |
3.1V |
Temperature |
-200°C to 1350° C (-328° F to 2462° F) |
Frequency |
0.5 Hz to 1000 kHz |
Accuracy (Basic DC V) |
0.025% |
(Basic AC V) |
0.4% |
Features
Feature |
Description |
Dual Displays |
50,000 count primary display |
|
5,000 count secondary display |
Backlight with 2 |
Bright white backlight for clear readings |
brightness selections |
in poorly lighted areas |
Fast Autorange |
Meter automatically selects best range - |
|
instantly |
AC+DC True RMS, ac |
Choices for AC only, AC and DC dual |
rms specified to 100 kHz |
display, or AC+DC readings |
dBm, dBV |
User selectable impedance references |
|
for dBm |
AutoHOLD |
Holds readings on display |
Continuity/Open Test |
Beeper sounds for Ohms readings below |
|
threshold or for momentary |
|
open circuit indication |
Fast Bar Graph |
51 Segments for peaking and nulling |
Duty Cycle/Pulse Width |
Measure time a signal is on or off in % |
|
or milliseconds |
MIN MAX/Fast MIN MAX |
Record Maximum, Minimum, and Average |
with elapsed and |
values. Real Time for MAX or MIN, elapsed |
Real Time Stamp |
time for AVG. |
|
Fast MIN MAX captures peaks to 250 sec. |
Closed Case Calibration |
No internal adjustments needed |
Battery/Fuse |
Battery or fuse replacement without |
Access Door |
voiding calibration |
Hi-Impact Overmold Case |
Integrated Protective Holster provides |
|
superior impact protection for your meter |
1For the 5,000 count mode, divide the number of least significant digits (counts) by 10.
2A residual reading of 8 to 180 digits with leads shorted, will not affect stated accuracy above 5% of range.
320 counts in dual display DC or AC + DC
410A continuous up to 35°C, less than 10 minutes 35° to 55°. 20A overload for 30 seconds maximum
5See AC conversion notes for AC mV and V.
Above specifications are subject to change without notice.
Detailed Specifications
Accuracy is specified for a period of one year after calibration, at 18° C to 28°C (64°F to 82°F) with relative humidity to 90%. Accuracy specifications are given as ± ([% of reading] + [number of least significant digits])
|
|
|
|
|
Accuracy |
|
|
|
|
|
45 Hz- |
20 Hz- |
1 kHz- |
10 kHz- |
20 kHz- |
Function |
Range |
Resolution |
1 kHz |
45 Hz |
10 kHz |
20 kHz |
100 kHz |
AC mV 1,2 |
50,000mV |
0.001mV |
0.4% + 40 |
2% + 80 |
5% + 40 |
5.5% + 40 |
15% + 40 |
|
500.00 mV |
0.01 mV |
0.4% + 40 |
2% + 80 |
5% + 40 |
5.5% + 40 |
8% + 40 |
|
3000.0 mV |
0.1 mV |
0.4% + 40 |
2% + 80 |
0.4% + 40 |
1.5% + 40 |
8% + 40 |
AC V 1,2 |
5.0000V |
0.0001V |
0.4% + 40 |
2% + 80 |
0.4% + 40 |
1.5% + 40 |
8% + 40 |
|
50.000V |
0.001V |
0.4% + 40 |
2% + 80 |
0.4% + 40 |
1.5% + 40 |
8% + 40 |
|
500.00V |
0.01V |
0.4% + 40 |
2% + 80 |
0.4% + 40 |
Not specified |
Not specified |
|
1000.0V |
0.1V |
0.4% + 40 |
2% + 80 |
0.4% + 40 |
Not specified |
Not specified |
dBV |
-56 to -6 |
0.01 dB |
0.1 dB |
0.2 dB |
0.5 dB |
0.5 dB |
1.4 dB |
|
-6 to +34 |
0.01 dB |
0.1 dB |
0.2 dB |
0.1 dB |
0.2 dB |
0.8 dB |
|
+34 to +60 |
0.01 dB |
0.1 dB |
0.2 dB |
0.1 dB |
Not specified |
Not specified |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Accuracy |
|
|
|
|
||
|
|
|
45 Hz- |
20 Hz- |
|
1 kHz- |
|
20 kHz- |
||||
Function |
Range |
Resolution |
1 kHz |
|
45 Hz |
|
20 kHz |
|
100 kHz |
|||
AC A |
500.00 A |
0.01 A |
0.75% |
+ 20 |
1% + 20 |
|
0.75% + 20 |
|
6% + 40 |
|||
|
5000.0 A |
0.1 A |
0.75% |
+ 5 |
1% + 5 |
|
0.75% + 10 |
|
2% + 40 |
|||
AC mA |
50.000 mA |
0.001 mA |
0.75% |
+ 20 |
1% + 20 |
|
0.75% + 20 |
|
9% + 40 |
|||
|
400.00 mA |
0.01 mA |
0.75% |
+ 5 |
1% + 5 |
|
1.5% + 10 |
|
4% + 40 |
|||
AC A |
5.0000A |
0.0001A |
1.5% + 20 |
1.5% + 20 |
|
6% + 40 |
|
Not specified |
||||
|
10.000A4 |
0.001A |
1.5% + 5 |
1.5% + 5 |
|
5% + 10 |
|
Not specified |
||||
|
|
|
|
|
|
|
|
|||||
|
|
|
Accuracy |
|
Accuracy Dual Display AC or AC+DC5 |
|||||||
|
|
|
|
|
|
20 Hz- |
45 Hz- |
|
1kHz- |
|||
Function |
Range |
Resolution |
DC |
|
|
45 Hz |
1 kHz |
|
20 kHz |
|||
DC mV |
50.000 mV |
0.001mV |
0.1% +20 |
|
2% |
+ 80 |
0.5% + 40 |
|
6% + 40 |
|||
|
500.00 mV |
0.01 mV |
0.03% + 2 |
|
2% |
+ 80 |
0.5% + 40 |
|
||||
|
|
|
|
|||||||||
|
3000.0 mV |
0.1 mV |
0.025% + 5 |
|
2% |
+ 80 |
0.5% + 40 |
|
|
|||
DC V |
5.0000V |
0.0001V |
0.025% + 103 |
|
2% |
+ 80 |
0.5% + 40 |
|
2% + 40 |
|||
|
50.000V |
0.001V |
0.03% |
+ 33 |
|
2% |
+ 80 |
0.5% + 40 |
|
|
||
|
500.00V |
0.01V |
0.1% + 23 |
|
2% |
+ 80 |
0.5% + 40 |
|
Not specified |
|||
|
1000.0V |
0.1V |
0.1% + 23 |
|
2% |
+ 80 |
0.5% + 40 |
|
Not specified |
|||
DC A |
500.00 A |
0.01 A |
0.25% |
+ 20 |
|
1% |
+ 20 |
1% + 20 |
|
|
2% + 40 |
|
|
5.000 A |
0.1 A |
0.25% |
+ 2 |
|
1% |
+ 10 |
0.75% + 10 |
2% + 40 |
|||
DC mA |
50.000 mA |
0.001 mA |
0.15% + 10 |
|
1% |
+ 20 |
0.75% + 20 |
2% + 40 |
||||
|
400.00 mA |
0.01 mA |
0.15% + 2 |
|
1% |
+ 10 |
1% + 10 |
|
|
3% + 40 |
||
DC A |
5.0000A |
0.0001A |
0.5% + 10 |
|
2% |
+ 20 |
2% + 20 |
|
|
6% + 40 |
||
|
10.000A4 |
0.001A |
0.5% + 2 |
|
1.5% + 10 |
1.5% + 10 |
|
5% + 40 |