2009/7/28 V01
AVR-1910/1610/1620/790/590 Firmware Update Instruction (Common for AVC-1620)
Nr. |
|
Contents |
|
Tools |
Remarks |
|
|
|
|
|
|
|
Follow this instruction and |
the operating instructions for service (1) |
PC with RS-232C terminal |
Commercially avaiable |
|
|
parts kit = "00DSPK-581 WRITING UNIT" which to be used wit (2) |
RS-232C cable 9P, D-sub, Straig Commercially avaiable |
1Writer Starter = "m3a0806v020046exe.zip" File size : 345,864 bytes (0.32 Mbytes)
"FlashSta.exe" |
|
Please download the Writer Starter software "Flash |
|
Available in SDI or web. |
|
Programmer M16C Flash Starter M3A-0806 Software |
|
Ver.2.0.0.46 Upgrade" from SDI or below URL. |
|
http://america.renesas.com/fmwk.jsp?cnt=/download_search_results.jsp&fp=/support/downloads/download_results&layerId=1216 |
|
|
|
2 Program File = "AVR1910_1610_Main Ver00.85.mot" |
Available in SDI. |
3Jig setting and the connection between jig and main unit. Connect CP1015 on MAIN PWB and
CX707 on JG209-10 with 8P connector cable. Set all the slide switch into the position as follows.
S702 |
VCSEL : 5V |
Service parts kit: |
Avaiable for service |
S706 |
CNVSS : H |
00DSPK-581 WRITING UNIT |
8P connection cable included |
S707 EPM : L |
|
|
|
S708 CE : H |
|
|
|
S709 DSPBOOT : H |
|
|
|
S702 VCSEL : 5V |
CP1015 on |
|
MAIN B'd |
S706 CNVSS : H |
|
S707 EPM : L |
|
S708 CE : H |
|
S709 DSPBOOT : |
CX707 on JG209-10. |
|
Caution!
Do not turn on the power of A/V amplifier, when A/V amplifier connects the "00DSPK-581 WRITING UNIT" with 8p connector cable. Because the customer's setting of A/V amplifier will be lost.
4 How to set main unit into firmware update mode. Put POWER ON/OFF switch on while pressing
"Surround <" + "MENU" (for all models)
buttons on front panel of main unit.
No LED and FL display should be lit (firmware update mode.)
1/6
5Operation with writer software. Procedure of writing software.
1)Start up "Flash Starter M3A-0806 Ver2.0.0.46" on PC.
2)Window of "FlashSta.exe"
3)Double click the file name of the "FlashSta.exe".
3) Click the "OK" button.
4) If A/V amplifer does not connect to "00DSPK-581 WRITING UNIT" (or PC) properly or Setting of the "00DSPK-581 WRITING UNIT"
is not correct, the following indication is displayed.
Please click the "Cancel" button, and confirm all connection and setting, and goes to item-3.
Cancel
5) Click the "Refer…" button.
2/6