Model: AVR-1601, AVR-1801

Subject: Resistors open.

Symptom: When the Power is turned on, resistors R141 and R142 in the

Power Supply Circuit on the MAIN Unit can fail due to in-rush current which will cause the Protect circuit to engage.

Solution: Replace the resistors R141 an R142 with the improved resistors listed below.

Parts:

Ref #

FORMER

 

NEW

 

 

Description

 

Part

Description

Part

 

 

 

Number

 

Number

R141,

RS14B2E1R0JNBST

 

963 9003

RS14B3AR22JNBST

244 2043

R142

(1/4W, 1Ω)

 

039

(S)(IW, 0.22 Ω)

982

Serial Number Range:

Replace upon customer claim.

______________________________________________________________________________________

CONFIDENTIALITY NOTICE:

The information contained in this document is intended for the exclusive use by DENON Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the DENON Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by DENON for any damage, injury or loss resulting from the misuse of the information contained in this document.