100 Corporate Drive Mahwah, NJ 07430
Service Bulletin
No. : OST-621
Date: April 27, 2007
_____________________________________________________________
Model: AVR-1601, AVR-1801
Subject: Resistors open.
Symptom: When the Power is turned on, resistors R141 and R142 in the
Power Supply Circuit on the MAIN Unit can fail due to in-rush current which will cause the Protect circuit to engage.
Solution: Replace the resistors R141 an R142 with the improved resistors listed below.
Parts:
Ref # |
FORMER |
|
NEW |
|
|
|
Description |
|
Part |
Description |
Part |
|
|
|
Number |
|
Number |
R141, |
RS14B2E1R0JNBST |
|
963 9003 |
RS14B3AR22JNBST |
244 2043 |
R142 |
(1/4W, 1Ω) |
|
039 |
(S)(IW, 0.22 Ω) |
982 |
Serial Number Range:
Replace upon customer claim.
______________________________________________________________________________________
CONFIDENTIALITY NOTICE:
The information contained in this document is intended for the exclusive use by DENON Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the DENON Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by DENON for any damage, injury or loss resulting from the misuse of the information contained in this document.