Data Sheet
Thermostatic Radiator Sensor, Type RAW with RTD Connection
Application
RAW/RTD 5215/5216
The RAW series is a programme of radiator thermostats which covers all central and district heating systems.
RAW is a self-actuating proportional controller with a small P-band.
RAW radiator thermostats are designed for use in 2-pipe domestic heating systems.
The sensors are equipped with RTD connection.
RAW 5216 is identical to 5215 except for the temperature range 16 - 28 °C.
The RAW 5215 sensor incorporates a frost protection setting for maximum user flexibility.
The RAW sensors also provide the option to limit the temperature range. On 013G5215 both maximum and minimum setting temperature can be limited. On 013G5216 only the maximum temperature can be limited.
The RAW design is particularly robust, with both End-Stop strength limits and sensor bending force limits being substantially above the requirements of the European Standard EN215.
Ordering and Technical |
Sensor range |
|
|
|
|
Data |
Product |
Model |
Colour |
Temp. |
Code no. |
|
range1) |
||||
|
|
|
|
|
|
|
RAW 5215 |
Built-in temperature sensor |
RAL 9016 |
8-28 °C |
013G5215 |
|
|
|
|
|
|
|
RAW 5216 |
Built-in temperature sensor, limited temperature area |
RAL 9016 |
16-28 °C |
013G5216 |
|
|
|
|
|
|
1) Xp = 2 K. (The valve closes at 2 °C higher room temperature)
Accessories and Spare |
Product |
Code no. |
|
Parts |
|
|
|
Theft protection |
013G5287 |
||
|
|||
|
|
|
Danfoss Heating Solutions |
VDFNP202 |
© Danfoss |
03/2011 |
1 |
Data Sheet |
Thermostatic Radiator Sensor, Type RAW with RTD Connection |
|
|
Temperature Setting
Mounting
|
* = Frost protection setting |
|
|
|
|
|
||
10 |
14 |
18 |
22 |
26 |
30 |
°C |
||
|
|
|
|
|
|
|
||
* |
1 |
2 . . . 3 . . . 4 |
|
5 |
|
|
||
|
|
|
||||||
|
|
|
|
|
|
|
|
|
8 |
12 |
16 |
20 |
24 |
28 |
°C |
The required room temperature is set by turning |
The temperature scales are stated according to |
the setting dial. The temperature scales show the |
European standards at Xp = 2°C. This means that |
correlation between scale values and the room |
the radiator thermostats close at a sensor |
temperature. The temperature values stated are |
temperature which is 2°C higher than stated on |
for guidance only as the obtained room |
the temperature scales. |
temperature will often be influ-enced by |
|
installation conditions. |
|
1. |
2. |
3. |
4. |
RAW5215 only
An open-end spanner is used for mounting the sensor onto the valve body (1 & 2).
The sensor should always be placed where the room air can circulate freely around it.
Setting the upper and lower limit
The thermostat features two tabs with which the temperature setting area can be decreased. If 4 should be max. setting, turn the thermostat to max. position (3) and press and hold right tab while turning the thermostat to 4 (3), now release tab. With the left tab the lower temperature must be turned to min. position (4).
2 |
VDFNP202 |
© Danfoss |
03/2011 |