Danfoss RAS-C 5023, RAS-C 5040, RAS-C 5041, RAS-C 5061, RAS-C 5042 Data sheet

0 (0)

Data Sheet

Thermostatic Sensors RAS-C

Application

RAS-C 5023 & 5040

RAS-C 5041 & 5061

RAS-C 5042

The RAS-C series is a programme of thermostatic radiator sensors, which covers all central and district heating systems.

RAS-C sensors are self-actuating proportional controllers with a small P-band., designed for use in 2-pipe domestic heating systems.

RAS-C sensors are equipped with a snap-lock mechanism, which ensures quick, firm and long lasting mounting onto the valve body, without the use of any tools.

All RAS-C sensors incorporates a Frost Protection Setting.

Furthermore, the RAS-C range includes models with features for positive shut-off and for temperature limitation to provide the customer with maximum flexibility.

RAS-C 5042 is equipped with 2 m of ultra-thin capillary tube, coiled up within the remote sensor housing. After sensor mounting capillary tube is pulled out to the required length.

The RAS-C construction is particularly robust, with both end-stop strength limits and sensor bending force limits being substantially above the requirements of the European Standard EN 215.

Ordering and

RAS-C thermostatic sensors

 

 

 

 

Specifications

Type

Sensor

Colour

Features

Setting range 1)

Code no.

 

RAS-C 50233)

Built-in

Black/White

Temp. limitation

 

013G5023

 

RAS-C 50403)

Built-in

Black/White

Positive shut-off

 

013G5040

 

RAS-C 50413)

Built-in

White

Positive shut-off

8 - 28 °C

013G5041

 

RAS-C 50423)

Remote 2)

Black/White

Capillary tube, 2 m

 

013G5042

 

RAS-C 5061

Built-in

White

Temp. limitation

 

013G5061

 

 

 

 

 

 

 

1)Temperatures stated for Xp = 2K, i.e. the valve is closed at 2 °C higher room temperature.

2)The remote sensor is delivered with 2 m of capillary tube coiled up within the sensor. When mounting the sensor, only the capillary tube required is uncoiled.

3)Manufactured to the highest standards, and are approved to the European standard EN 215.

Danfoss Heating Solutions

VDTLO302

© Danfoss

03/2011

1

Danfoss RAS-C 5023, RAS-C 5040, RAS-C 5041, RAS-C 5061, RAS-C 5042 Data sheet

Data Sheet

Thermostatic Sensors RAS-C

 

 

Mounting

The Danfoss snap-on coupling is easy to mount

 

and requires no use of tools, once the valve cover

 

has been removed.

 

The sensor is fitted to the valve by applying a

 

gentle pressure. When the sensor is in place, the

 

snap-on mechanism is activated and the sensor

 

has been correctly mounted.

 

If mounting and dismounting are carried out

 

again, the mechanism must be tightened

 

manually by turning the tightening ring.

Theft Protection

 

After mounting the sensor, press in the theft protection clip.

The sensor is now locked to the valve.

To remove the theft protection without damaging the sensor, use Danfoss special tool:

Code no. 013G1231

Setting the Temperature

 

 

 

= Frost protection setting

 

 

 

 

 

 

 

 

 

 

 

10

14

18

22

26

30

°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

1

2

3

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

12

16

20

24

28

°C

 

 

 

 

The required room temperature is set by turning the setting dial. The temperature scales show the correlation between scale values and the room temperature. The temperature values stated are for guidance only as the obtained room temperature will often be influenced by installation conditions.

The temperature scales are stated according to European standards at Xp = 2°C. This means that

the radiator thermostats close at a sensor temperature which is 2°C higher than stated on the temperature scales.

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

VDTLO302

© Danfoss

03/2011

 

 

 

 

 

Danfoss Heating Solutions

Loading...
+ 2 hidden pages