FLEXIDOME corner 9000 IR
VCN-9095
en OSD Menu
|
Table of Contents | |
3 |
|
|
|
Table of Contents |
|
|
|
|
|
1 |
Configuration |
4 |
1.1 |
Menus |
4 |
1.1.1 |
Menu navigation |
4 |
1.1.2 |
Top level menus |
4 |
1.2 |
Pre-defined modes |
6 |
1.3 |
Day/Night switching |
7 |
1.4 |
Camera control communication (Bilinx) |
7 |
1.5 |
Main menu structure |
8 |
1.5.1 |
Mode submenu |
8 |
1.5.2 |
ALC submenu |
9 |
1.5.3 |
Day/Night submenu |
11 |
1.5.4 |
Enhance / Dynamic Engine submenu |
13 |
1.5.5 |
Color submenu |
15 |
1.5.7 |
VMD submenu |
17 |
1.6 |
Install menu structure |
18 |
1.6.1 |
Language submenu |
19 |
1.6.2 |
Synchronization submenu |
20 |
1.6.3 |
Alarm I/O submenu |
21 |
1.6.4 |
Connections submenu |
22 |
1.6.5 |
Test signal submenu |
22 |
1.6.6 |
Camera ID submenu |
22 |
1.6.7 |
Privacy masking submenu |
24 |
1.6.9 |
Defaults submenu |
25 |
| |
4 en | Configuration |
FLEXIDOME corner 9000 IR |
|
|
The camera normally provides an optimal picture without the need for further adjustments. Advanced set-up options are available in a menu system for getting the best results under special circumstances.
The camera implements your changes immediately so that before and after settings are easily compared.
Five keys are used for navigating through menu system.
Up button
Menu/Select button (center)
Right button
Down button
Left button
–Use the up or down keys to scroll through a menu.
–Use the left or right keys to move through options or to set parameters.
–To close all menus at once hold down the menu/select key
until the menu display disappears or continually select the Exit item.
Some menus automatically close after about two minutes; other menus have to be closed manually.
There are two upper level menus: a Main menu and an Install menu. The menus have functions that can be selected directly or submenus for more detailed set-up.
–To access the Main menu, press the menu/select button (center) for less than 1 second. The Main menu appears on the monitor. The Main menu allows you to select and setup the picture enhancement functions. If you are not happy
AM18-Q0661 | v1.0 | 2013.06 |
OSD Menu |
Bosch Security Systems |
FLEXIDOME corner 9000 IR |
Configuration | en 5 |
|
|
with your changes, you can always recall the default values for the mode.
–The camera also has an Install menu in which the installation settings can be set. To access the Install menu, press the menu/select button (center) for longer than 2 seconds.
Bosch Security Systems |
OSD Menu |
AM18-Q0661 | v1.0 | 2013.06 |
6 en | Configuration |
FLEXIDOME corner 9000 IR |
|
|
1.2Pre-defined modes
There are six pre-defined modes with settings to make configuration easier. You can select one of the six pre-defined modes in the Install/Mode submenu. The modes are defined as follows;
1.24-hour
Default installation mode to provide stable pictures over a 24-hour period. These settings are optimized for out-of- the-box installation.
2.Traffic
Capture high-speed objects using default shutter in variable lighting conditions.
3.Low light
Provide extra enhancement, such as AGC and SensUp to make usable pictures in low-light conditions.
4.Smart BLC
Settings optimized to capture details in high contrast and extremely bright-dark conditions.
5.Low noise
Enhancements are set to reduce picture noise. Useful for conditional refresh DVR and IP storage systems because reducing noise reduces the amount of storage required.
6.Vibrant
This mode has enhanced contrast, sharpness and saturation.
AM18-Q0661 | v1.0 | 2013.06 |
OSD Menu |
Bosch Security Systems |
FLEXIDOME corner 9000 IR |
Configuration | en 7 |
|
|
The camera is equipped with a motorized IR filter. The mechanical IR filter can be removed in low-light or IR illuminated applications by software configuration settings. If Auto switching mode is selected, the camera automatically switches the filter depending on the observed light level. The switching level is programmable. In Auto switching mode the camera prioritizes motion (the camera gives sharp images
without motion blur as long as the light level permits) or color (the camera gives color pictures as long as the light level permits). The camera recognizes IR illuminated scenes to prevent unwanted switching to color mode.
There are four different methods of controlling the IR filter:
–via Bilinx communication,
–automatically, based on the observed light levels, or
–as part of the programmable mode profile.
This camera is equipped with a coaxial communications transceiver (also referred to as Bilinx). In combination with VPCFGSFT, the camera setting can be changed from any point along the coaxial cable. All menus can be accessed remotely giving full control of the camera. With this method of communication it is also possible to disable the local keys on the camera.To avoid loss of communication on an installed camera, the Communication On/Off selection is not available while using remote control. This function can only be accessed with the camera buttons. Bilinx communications can only be disabled using the buttons on the camera.
When the Bilinx communications link is active, the buttons on the camera are disabled.
Bosch Security Systems |
OSD Menu |
AM18-Q0661 | v1.0 | 2013.06 |
8 en | Configuration |
FLEXIDOME corner 9000 IR |
|
|
Item |
Selection |
Description |
|
|
|
Mode |
Submenu |
Sets up operating modes 1 to 6 |
|
|
|
Exposure |
Submenu |
Exposure control |
|
|
|
Day/Night |
Submenu |
Day/Night for color/mono operation |
|
|
|
Enhance |
Submenu |
Picture enhancement and performance |
|
|
|
Color |
Submenu |
White balance and color rendition |
|
|
|
VMD |
Submenu |
Video motion detection |
|
|
|
Image |
Submenu |
Sets up digital zoom or digital image |
Adjustment |
|
stabilization |
|
|
|
Item |
Selection |
Description |
|
|
|
Mode |
1 to 6 |
Selects operating mode. |
|
|
|
Mode ID |
Alphanumeric |
Mode name (11 characters maximum) |
|
|
|
Copy active |
Available |
Copies current mode settings to the |
mode |
mode |
mode number selected. |
|
numbers |
|
|
|
|
Mode |
Submenu |
Restores camera to the factory default |
Defaults |
|
settings. |
|
|
|
EXIT |
|
Returns to main menu. |
|
|
|
AM18-Q0661 | v1.0 | 2013.06 |
OSD Menu |
Bosch Security Systems |
FLEXIDOME corner 9000 IR |
Configuration | en 9 |
|
|
Item |
Selection |
Description |
|
|
|
ALC level |
-15 to +15 |
Selects the video level range. A |
|
|
positive value is more useful for low- |
|
|
light conditions; a negative value is |
|
|
more useful for very bright |
|
|
conditions. |
|
|
Some ALC adjustment may improve |
|
|
scene content when Smart BLC is |
|
|
enabled. |
|
|
|
ALC speed |
Slow, medium, |
Adjusts the speed of the video level |
|
fast |
control loop. For most scenes it |
|
|
should remain at the default value. |
|
|
|
Shutter |
AES, FL, Fixed |
AES (auto-shutter) - the camera |
|
|
automatically sets the optimum |
|
|
shutter speed. |
|
|
FL - flickerless mode avoids |
|
|
interference from light sources. |
|
|
FIXED - allows a user defined shutter |
|
|
speed. |
|
|
|
Default (AES) |
1/50 (PAL) |
In DEFAULT (AES) mode, the camera |
shutter |
1/60 (NTSC), |
tries to maintain the selected |
or |
1/100 (PAL) |
shutter speed as long as the light |
Fixed shutter |
1/120 (NTSC), |
level of the scene is high enough. |
|
1/250, |
In Fixed mode, selects shutter |
|
1/500, |
speed. |
|
1/1000, |
|
|
1/2000, |
|
|
1/4000, |
|
|
1/10K, |
|
|
1/100K |
|
|
|
|