LG PRHR040 User Manual

0 (0)

61799 LG Multi V Catalogue 4/5/07 2:15 pm Page 1

2007

www.lge.com

Air Conditioning System

If you need a highly efficient air conditioning system in your building, LG is the right choice for you.

61799 LG Multi V Catalogue 4/5/07 2:15 pm Page 2

Great Company Great People

Brief History

Establishment

1947

Establishment of the LG Group

1958

Establishment of

LG Electronics Inc.

1962

Establishment of

Digital Appliance Company

Growth

 

1968

Manufactured Korea’s first air conditioners

Test Tower

1985

Introduced Korea’s first Inverter air conditioners

 

1986

Exported Korea’s first window-type air conditioner

U.S.

1989

Won the approval of “UL’s MDP & CSA’s EEVP”

1993

Obtained ISO 9001 Certification from “BSIQA”

1994

Export Records US$ 100 Million

Global

1995 Establishment of L G E TA in China

Expansion

1997

Establishment of

L G E I L in India

1999

Establishment

of

L G E AT in Turkey

1999

Establishment

of

L G E M H in Vietnam

2001

Establishment

of

L G E A Z in Brazil

2002

Establishment

of

L G E T H in Thailand

2002

Establishment

of

L G E I N in Indonesia

2004

Turnover of US$1 . 4 Billion dollars

2006

Achieved No.1 position for 7 years ( 2000~2006)

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 3

LG Air Conditioner Global

LG Air Conditioning Division, Korea

LGE Tianjin Appliance Co., Ltd. China

LG Electronics Thailand

LG Electronics Arcelik Turkey

LGE New Delhi Ltd., India

LGE Haiphong Inc., Vietnam

LGE da Amazonia Ltd., Brazil

LG Electronics Indonesia

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 4

Indoor unit

52

55

66

68

70

 

 

Wall

Ceiling Cassette

Ceiling Cassette

 

Series

Mounted

- 1way

- 2way

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 5

10

Outdoor unit

 

16

28

42

72

 

74

 

76

 

78

 

80

Ceiling Cassette -

 

Ceiling & Floor

 

Ceiling

 

Ceiling

 

Ceiling

 

 

 

 

4way

 

 

 

Suspended

 

Concealed Duct

 

Concealed Duct

 

 

 

 

 

 

- High Static

 

- Low Static

82

84

86

Ceiling

Floor Standing

Floor Standing

Concealed Duct

- With Case

- Without Case

- Built in

 

 

Network solution & Accessory

90

 

90

 

92

 

93

 

94

 

95

 

96

 

97

 

98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Individual

 

Simple Central

 

Deluxe Central

 

PC Based

 

PDI

 

BNU-LW

 

BNU-BN

 

Accessory

 

 

Controller

 

Controller

 

Controller

 

Central

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller

 

 

 

 

 

 

 

 

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 6

Outdoor unit line up

HP

5

8

10

12

14

16

18

20

Heat pump

Heat recovery

Heat pump

06 _ Air conditioning system

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 7

22

24

26

28

30

32

34

36

38

40

Air conditioning system _ 07

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 8

Indoor unit line up

Btu / h

7k

9k

12k

 

Panel

Series

Wide

 

 

Mirror

SRAC

Wall Mounted

 

1way

 

2way

Ceiling

Cassette

4way (570*570)

4way (840*840)

Ceiling & Floor

Ceiling Suspended

High Static

Ceiling

Concealed Low Static

Duct

Built-in

With Case

Floor

Standing

Without Case

08 _ Air conditioning system

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 9

18k

24k

28k

36k

42k

48k

Air conditioning system _ 09

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 10

Outdoor unit

The MULTI V system is composed of serially arranged refrigerant piping, and multiple indoor units connected to one outdoor unit. It is a highly efficient system that offers outstanding energy reduction, simple and easy design and installation, and the ability to connect to many types of indoor unit for all types of application.

16

42

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 11

28

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 12

Pursuing the market needs of high energy efficiency and environmental friendliness.

A line up with a wide range of model/capacity selection

The various selection of outdoor units coupled with the wide range of indoor units, means that the system has the ability to make any space comfortable whether it be a small shop, residential application, or large office building.

4WAY Cassette

1WAY Cassette

Ceiling Concealed Duct

Mirror

Wall Mounted

Floor Standing

Longer field piping runs for flexible installation

With a maximum pipe run of 150m from the outdoor unit to the furthest indoor unit, there is greater choice of where the outdoor and indoor units can be positioned. Therefore the system is suitable for installation into most types of building.

Outdoor unit

Max height

Actual piping longest

50m

length 150m

 

Elevation among

 

indoor units 15m

12 _ Air conditioning system

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 13

Outdoor unit

Outdoor unit

incorporates inverter compressor and fan motors.

Why inverter ?

-Higher efficiency

-Reduced operation noise

-Less vibration

-Enhanced capacity control

Automatic addressing between outdoor and indoor units

The addressing between outdoor unit and indoor units is carried out by the touch of a button. When the addressing is complete, the system is ready to run.

Manual addressing

 

Auto addressing

 

 

Indoor unit Indoor unit

Indoor unit

Indoor unit

Indoor unit

Indoor unit

Wired remote

Wired remote

Wired remote

Wired remote

Wired remote

Wired remote

control

control

control

control

control

control

Non-polarised communication wiring

The communication wiring can be installed polarised, non-polarised, or a combination of the two, and the outdoor unit will sort out the mistakes during automatic addressing.

Polarity connection

 

 

 

Non-polarity connection

 

 

 

 

 

 

Outdoor

Indoor

Indoor

 

 

 

Outdoor

Indoor

Indoor

 

 

 

unit

unit 1

unit 2

 

 

 

unit

unit 1

unit 2

Outdoor unit control box

 

 

Outdoor unit control box

 

 

indoor

outdoor

 

 

 

 

 

 

central controller

 

 

indoor

outdoor

 

 

 

 

unit

unit

 

 

central controller

 

 

 

 

 

 

 

 

 

E F C D Vcc GND

 

 

unit

unit

 

 

 

 

 

 

 

 

E F

C D Vcc GND

 

 

 

 

 

 

 

 

 

 

 

indoor unit 1

indoor unit 2

•••

indoor unit 1

indoor unit 2

° ° °

Air conditioning system _ 13

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 14

Pursuing the market needs of high energy efficiency and environmental friendliness.

Urethane coated PCB

- Protects PCB from oxidization

- Prevents errors that may be caused Urethane coating by moisture and dust

-Strengthens electrical insulation

-Kepts components stable from vibration.

Indoor unit with interior concept

Indoor units with unique stylish designs blend in with refined interior.

14 _ Air conditioning system

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 15

Outdoor unit

Outdoor unit

Neo Plasma Air Purifying System (applied models only)

LG’s unique NEO Plasma Air Purifying System is equipped with 7 specialized filters in 5 separate stages to enhance its cleaning power. It reduces fine dust and mold, unpleasant odors and cigarette smoke as air passes through each filter.

1

2

3

4

5

Polluted Air

1. Pre Filter

The antibacterial pre-filter primarily reduces large dust, mold and quilt dust.

2. Nano Carbon Filter

Nano-size carbon filters removes fine odorous particles from the household air resulting in a more pleasant environment.

What is Nano Carbon Ball?

Microscopic sized (1/1000000000) filter to ensure optimal filtration of odors.

200~500nm

3. Triple Filter

The triple filter consists of three specialized filters to reduce the symptoms associated with various organic compounds including formaldehyde. It also has the ability to reduce unpleasant odors creating a more comfortable environment.

Clean Air

5. Plasma Filter

The PLASMA Air Purifying System developed uniquely by LG not only reduces microscopic contaminants and dust, but also reduces house mites, pollen, and pet fur to reduce allergy and asthma symptoms.

Test Result Certification

Bio Active

Bacteria,

 

 

Virus

 

 

Site

 

 

 

 

 

Nano

Nano

Nano

Nano

Particle

Particle

Particle

Particle

Active State

Bacteria Selective

Bacteriolysis

Regeneration

 

Capture

 

(Active State)

4. Nano Bio Fusion Filter

Nano bio fusion filters allow their nanosize bio enzymes to directly penetrate through cell walls of some bacteria and allergen to decompose its cell nuclei.

Distinctions from Conventional Filters

Conventional

Nano Bio Fusion Filter

Simply inactivate

Destroy bacteria but allow

The bio enzyme destroys cell walls

bacteria

part of them to survive

and nuclei of some bacteria and

 

 

allergens.

Air conditioning system _ 15

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 16

Hotel

School

Office

Factory

Applications

-Hotel

-School

-Office

-Factory

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 17

Outdoor unit

What is

is a two pipe heat pump system, which is available from 5Hp (single module) up to 40Hp (combination multiple outdoor units together). Up to 40 indoor units can be connected to one system, reducing installation material cost, and installation time. Combined with the many control options on offer, the system can offer a total building solution.

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 18

Installation Space

User satisfaction is further increased with , by reducing the installation area through efficient utilisation of space assisted by the design of the outdoor unit.

High efficiency linear control

allows capacity control in the range of 10-130% according to the indoor units load requirement. This is carried out by applying the optimised control algorithm using the inverter and constant speed compressors as the load increases/decreases. Combined with the outdoor unit inverter fan motors, this highly efficient inverter system also offers low noise operation, outstanding load response (quick and comfortable cooling and heating), and excellent energy reduction.

Inverter

Constant speed compressor

Highly efficiency linear control

compressor

 

 

Outstanding installation space utilisation

The two way air induction (front and rear), and top discharge structure, allows outdoor units to be placed directly next to each other - offering reduced installation space, and reduced system footprint.

Conventional

Top discharge with 3way inlet

Top discharge with 2way inlet

Installation of multiple outdoor units in this way can reduce installation by up to 30% compared to equivalent systems on the market (some of which use the 3 way air induction and top discharge method).

18 _ Air conditioning system

61799 LG Multi V Catalogue 4/5/07 2:16 pm Page 19

Economy

ensures an economic life due to its high efficiency operation, reduced installation material usage, and therefore reduced installation cost.

Long and reduced field piping for flexible installation

Outdoor unit

Outdoor unit

gives you the ability to connect multiple outdoor units together to form one system (therefore one set of pipes entering the building). This coupled with the long field piping runs makes the system not only very flexible in the type of buildings where it can be installed, but can reduce installation costs and even reduce installation space (especially within the risers).

Conventional Sets of existing 10HP outdoor units are separately installed.

refrigerant piping (liquid pipe + gas pipe)

15% reduction of sleeve

pipe diameter as

compared to existing

ones.

Air conditioning system _ 19

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 20

Efficiency

uses the cutting edge artificial intelligence (known as ‘fuzzy control’) to obtain efficient operation and reduce noise.

Components fully protected from the elements

1.Electrical and mechanical parts are totally sealed in their enclosures.

2.Separated equipment space between compressors/control boxes, and heat exchangers.

3.Because the electrical and mechanical parts are sealed in their own enclosures, this makes them much more resistant to environment factors which can cause corrosion (such as dust and rain) - thus improving the lifetime of the outdoor unit.

Heat exchanger

Safety cover

Alternate compressor cycling / back-up function

1. Duty-cycling function

Normal running conditions

alternates several compressors conditionally to elongate product life span.

to meet diverse load in operation

1.inverter + constant speed 2 - inverter only

2.inverter + constant speed 3 - inverter only

3. inverter + constant speed 1 - inverter only

inverter

const.

const.

const.

 

speed 1

speed 2

speed 3

 

 

MULTI compressor system with longer life cycle for each compressor due to alternate operation

2. Back-up function

can accommodate back up compressor operation when one compressor fails to raise product reliability.

to back up when constant speed compressor 2 is out of order

1.inverter + constant speed 2 (out of order)

2.inverter + constant speed 1 (back up operation)

Compressor failure situation

inverter

const.

const.

const.

 

speed 1

speed 2

speed 3

Alternative compressor starts to run

20 _ Air conditioning system

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 21

Outdoor unit

Outdoor unit

Subcooling circuit technology

The double tube heat exchanger (LG patent) improves heating and cooling capacity due to the advanced subcooling circuit.

Double tube heat exchange

From outdoor

Linear expansion valve

To indoor

2 phase fluid

Liquid phase

spiral tube

Fuzzy control system

The fuzzy control system enables optimum conditioning by quickly attaining and maintaining the desired temperature for a much more pleasant and comfortable environment.

Existing control

Target temp.

Fuzzy control

Time

Air conditioning system _ 21

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 22

Longer piping, higher elevation

Reliability tests have proved that installations with piping length of 150m and elevation up to 50m are possible.

elevation 50m

total piping length : 300m actual longest piping length : 150m

Wide operation range

Wide operation range

-Cooling mode : -5°C DB - 43°C DB

-Heating mode : -20°C WB - 24°C WB

Heating mode

 

 

Cooling mode

0 C

 

 

0 C

-20 C

 

 

-5 C

24 C

43 C

22 _ Air conditioning system

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 23

Convenience

From installation to maintenance and service,

adds convenience to

cutting-edge technology.

 

Flexible pipe installation in 3 directions

3 directions

Convenient swing doors/electrical component enclosures

The swing door design (using the electrical component enclosures) enables easy access to compressors and piping for service and maintenance purposes.

Inverter

Main

board

board

is easy to load, un-load and move around

Sections cut into the base of the unit, for fork lift or pallet truck access. Enables easy loading for transportation, and easy moving when the unit is being installed/positioned.

Outdoor unit

Outdoor unit

Air conditioning system _ 23

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 24

Outdoor unit specifications

Heat pump

24 _ Air conditioning system

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 25

Outdoor unit

Outdoor unit

Heat pump

Air conditioning system _ 25

LG PRHR040 User Manual

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 26

Outdoor unit specifications

Heat pump

26 _ Air conditioning system

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 27

Outdoor unit

Outdoor unit

Heat pump

Air conditioning system _ 27

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 28

Computer room

Office

Fitness room

Locker room

Applications

-Machine room / computer room, office

-Fitness room, locker room

-Kitchen, restaurant

-According to customer’s need,heating & cooling may be required simultaneously. (hotel, office, etc.)

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 29

Outdoor unit

What is

is a three pipe heat recovery system, which means simultaneous cooling and heating is possible from one system. This is achieved using the three pipes from the outdoor unit in conjunction with heat recovery boxes. The heat recovery boxes (or HR boxes) are installed between the outdoor unit and indoor units, and the refrigerant is distributed to the indoor units in its required state (depending on whether or not cooling or heating is required). Heat that is removed from one room can be used elsewhere within the system where it is required, thus making the even more efficient. The

is available from 8Hp (single module) up to 40Hp (combining multiple outdoor units together). Up to 40 indoor units can be connected to one system, reducing installation material cost, and installation time. Combined with the many control options on offer, the system can offer a total building solution.

61799 LG Multi V Catalogue 4/5/07 2:17 pm Page 30

Technology

Simultaneous heating and cooling with one outdoor unit -

Your environment is ensured of optimum conditions regardless of season or space.

Technology

Existing mode switching type

Cooling

Cooling

Heating

Cooling

Heating based operation

:Many indoor units run in heating mode, a few run in cooling mode

Cooling based operation

:Many indoor units run in cooling mode, a few run in heating mode

-Outdoor temperature: 7°C DB / 6°C WB

-Indoor temperature : 20°C DB / 15°C WB

Wide operation range

Wide operation range

 

 

 

 

 

-

Cooling mode:

- 5°C WB to 43°C WB

 

 

 

 

 

 

 

 

 

 

 

 

 

-

Heating mode:

- 20°C DB to 24°C DB

 

 

 

 

 

 

 

 

 

 

 

 

-

Synchronous mode:

-10°C DB to 30°C DB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 _ Air conditioning system

Loading...