LG R22AWN-NC11 Owner’s Manual

0 (0)
<![if ! IE]>

<![endif]>ENGLISH

OWNER’S MANUAL

AIR CONDITIONER

Please read this manual carefully before operating your set and retain it for future reference.

TYPE : WALL MOUNTED

Indoor Unit

Outdoor Unit

R18AWN-NC11

R18AWN-UC11

R22AWN-NC11

R22AWN-UC11

R24AWN-NC11

R24AWN-UC11

R28AWN-NC11

R28AWN-UC11

www.lg.com

P/NO : MFL57942722

<![if ! IE]>

<![endif]>ENGLISH

2

TIPS FOR SAVING ENERGY

 

 

TIPS FOR SAVING ENERGY

Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:

Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.

Block sunlight with blinds or curtains while you are operating the air conditioner.

Keep doors or windows closed tightly while you are operating the air conditioner.

Adjust the direction of the air flow vertically or horizontally to circulate indoor air.

Speed up the fan to cool or warm indoor air quickly, in a short period of time.

Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.

Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.

For your records

Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:

Model number :

Serial number :

You can find them on a label on the side of each unit.

Dealer’s name :

Date of purchase :

SAFETY PRECAUTIONS 3

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product

! WARNING

It can result in serious injury or death when the directions are ignored

! CAUTION

It can result in minor injury or product damage when the directions are ignored

! WARNING

Installation or repairs made by unqualified persons can result in hazards to you and others.

Installation MUST conform with local building codes or, in the absence of local codes, with the Nation Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical Code Part1 CSA C.22.1.

The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

Installation

Use a standard circuit breaker and fuse conforming with the rating of the air conditioner. Failure to do so may result in electric shock or product failure.

Contact an authorized service center when you install or relocate the air conditioner. Failure to do so may result in serious injury or product failure.

Always use a power plug and socket with a ground terminal.Failure to do so may result in electric shock or product failure

Install the panel and the cover of the control box safely. Failure to do so may result in explosion or fire.

Install a dedicated electric outlet and circuit breaker before you use the air conditioner. Failure to do so may result in electric shock or product failure.

Use a standard circuit breaker and fuse conforming with the rating of the air conditioner. Failure to do so may result in electric shock or product failure.

Do not modify or extend the power cable. If the power cable or cord has scratches or skin peeled off or deteriorated then it must be replaced. It may result in fire or electric shock.

Be cautious when you unpack or install the air conditioner. Failure to do so may result in serious injury or product failure.

Contact an authorized service center when you install or relocate the air conditioner. Failure to do so may result in serious injury or product failure.

Do not install the air conditioner on an unstable surface or where there may be a danger of it falling. It may result in death, serious injury, or product failure.

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

4 SAFETY PRECAUTIONS

Operation

Do not let the air conditioner run for a long time when the humidity is very high or when a door or window has been left open. Failure to do so may result in product failure.

Make sure that the power cord is not pulled or damaged while the air conditioner is operating. Failure to do so may result in fire, electric shock, or product failure.

Do not place any objects on the power cord. It may result in electric shock or product failure.

Do not turn on or off the air conditioner by plugging in or unplugging the power plug. It may result in fire or electric shock.

Do not touch, operate or repair the air conditioner with wet hands. It may result in electric shock or product failure.

Do not place a heater or other heating appliances near the power cable. It may result in fire, electric shock, or product failure.

Do not allow water to run into the air conditioner. It may result in explosion or fire.

Do not leave flammable substances such as gasoline, benzene and thinner near the air conditioner. It may result in explosion or fire.

Do not use the air conditioner for an extended period of time in a small place without ventilation. Ventilate the place regularly. Failure to do so may result in explosion or fire.

When there is a gas leak, ventilate sufficiently before using the air conditioner again. Failure to do so may result in explosion or fire.

Unplug the power plug if there is a noise, smell or smoke coming from the air conditioner. Failure to do so may result in explosion or fire.

Stop operating and close the window in strom or hurricane.If possible remove the product from the window before hurricane arrives

Do not touch the electrostatic filter after opening the front grille. Failure to do so may result in electric shock or product failure.

Contact an authorized service center when the air conditioner is submerged into water due to flooding. Failure to do so may result in explosion or fire.

Be cautious water could not enter the product

Make sure to ventilate sufficiently when this air conditioner and a heating appliance such as a heater are used simultaneously. Failure to do so may result in fire, serious injury, or product failure.

Turn the main power off and unplug the power plug when you clean or repair the air conditioner. Failure to do so may result in death, serious injury, or product failure.

Unplug the power plug when the air conditioner is not used for an extended period of time. Failure to do so may result in product failure.

Do not place any objects on the air conditioner. It may result in product failure.

For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent that causes corrosion or damage on the unit. Harsh detergent may also cause failure of product, fire, or electronic shock.

SAFETY PRECAUTIONS 5

! CAUTION

Installation

Make sure to check if there is a refrigerant leak after you install or repair the air conditioner. Failure to do so may result in product failure.

Install the drain hose properly for smooth drainage of condensed water. Failure to do so may result in product failure.

Keep level even when installing the product.

Install the air conditioner where the noise from the outdoor unit or the exhaust gas will not inconvenience the neighbors. Failure to do so may result in conflict between neighbors.

When transporting the equipment, there should be at least 2 or more people, or a forklift. It may result in serious injury.

Do not install the air conditioner where it will be exposed to sea wind (salt spray) directly. It may result in product failure.

Operation

Do not expose people, animals or plants to the cold or hot wind from the air conditioner. It may result in serious injury.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. It may result in death, fire or electric shock.

Do not block the inlet or outlet of air flow. It may result in explosion or product failure.

Do not use strong cleaning agents or solvents when you clean the air conditioner, or spray water. Use a smooth cloth. It may result in serious injury or product failure.

Never touch the metal parts of the air conditioner when you remove the air filter. It may result in serious injury or product failure.

Do not place any objects on the air conditioner. It may result in product failure.

Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if necessary.

Do not insert hands or other objects through the air inlet or outlet while the air conditioner is operating. It may result in electric shock.

Do not drink the water drained from the air conditioner. It may result in serious health complications.

Use a sturdy stool or ladder when you clean, maintain or repair the air conditioner at a height. Failure to do so may result in serious injury or product failure.

Do not mix the batteries for the remote control with other types of batteries or mix new batteries with used batteries. Failure to do so may result in product failure.

Do not recharge or disassemble the batteries. Failure to do so may result in explosion, fire or serious injury.

Stop using the remote control if there is a battery fluid leak. If your cloth or skin is exposed to the battery fluid from a leak, wash it off with clean water. Failure to do so may result in serious injury.

If you swallow the battery fluid from a leak, wash out the inside of your mouth thoroughly and then consult a doctor. Failure to do so may result in serious health complications.

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

6

TABLE OF CONTENTS

 

 

TABLE OF CONTENTS

2TIPS FOR SAVING ENERGY

3IMPORTANT SAFETY INSTRUCTIONS

7BEFORE USE

7Components

8Using the remote control

9How to insert the Batteries

9Wireless Remote Controller Maintenance

10OPERATING INSTRUCTION

10Operation Mode

11Auto Changeover Operation

11Healthy Dehumidification Operation

12Air Circulation Operation

12 Auto Clean Operation

12PLASMA Purification Operation

13Energy-Saving Cooling Mode

13 Display lamp on/off function

13Setting the Current Time

14Timer Setting

14 To cancel the timer setting

14Sleep Mode Operation

15Horizontal Vane Control

15Vertical Louver Control

16Jet Cool/Heat Operation

17MAINTENANCE

18Cleaning the air filter

18Cleaning the anti-allergy filter and triple filter

18Cleaning the plasma filter

19Forced operation

19Auto Restart Function

20TROUBLESHOOTING

20 Self-diagnosis function

20 Before requesting service

LG R22AWN-NC11 Owner’s Manual

BEFORE USE

7

 

BEFORE USE

Components

Indoor unit

Air inlet

 

Plasma filter

 

 

 

Air filter

ON/OFF button

Air inlet

 

 

Front grille

 

 

 

 

On/ Off button

 

 

 

Signal receiver

Triple filter

Operation lamp

 

Operation lamp

Signal Receiver

 

 

 

 

Air outlet

Horizontal vane

Air filter

Air deflector

Vertical louver Allergy free filter

Air outlet

(Vertical louver & Horizontal vane)

 

 

* The feature can be changed according a type of model.

! NOTE

The number of operation lamps and their locations may vary, depending on the model of the air conditioner.

Outdoor unit

Air Inlet

 

 

Connecting

 

Wires

 

Piping

Air Outlet

 

Base Plate

Drain Hose

 

<![if ! IE]>

<![endif]>ENGLISH

* The feature can be changed according a type of model.

Loading...
+ 16 hidden pages