LG Refrigeration Compressors
Refrigerants:
R 134a
R 600a
Hermetic
Compressors
Compressor Name Code:
Example:
MA 69 L A E G
Series name
MA |
|
MB |
Displacement |
MC |
Ex) 69 = 6.9cc/rev. |
MQ |
Application category |
|
|
|
L : R134a, LBP |
|
H : R134a, HBP |
|
N : R600a, LBP |
|
Improvement order |
|
A |
|
B |
|
C |
|
D |
|
E |
|
F |
|
H,K,J,M,N – AL-Wire |
Motor type
G : RSIR, PTC
F : CSIR, PTC
M : RSCR, PTC
H : CSR, PTC
P : CSIR, RELAY
Rated voltage & Frequency
A : 110V 50/60Hz |
P : 110V 50Hz |
B : 220V 50/60Hz |
Q : 110-115V 60Hz |
C : 115V 60Hz |
S : 200-220V 50Hz |
D : 220V 60Hz |
200V 60Hz |
E : 220-240V 50Hz |
T : 220-240V 50Hz |
F : 127V 60Hz |
220V 60Hz |
J : 220V 50Hz |
U : 110-127V 60Hz |
K : 110V 60Hz |
|
Serial Number:
* LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already agreed.
Electrical Wiring Diagrams :
RSIR - PTC
CSIR - PTC
CSIR – CURRENT RELAY
RSCR - PTC
CSCR - PTC
TERMINAL BODY ASM -TYPE A
* LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already agreed.
Electrical Wiring Diagrams : |
|
Terminal Body ASM – Type B |
RSCR – (E-PTC) |
|
|
|
Cord Lock |
|
ASM |
CSCR – (E-PTC) |
|
Motor Types
Motor Type |
Overload |
Starting Device |
Capacitors |
||
|
|
|
|
||
Protector |
PTC |
Current |
Starting |
Running |
|
|
|
Starter |
Relay |
||
|
|
|
|
||
RSIR |
Yes |
Yes |
|
|
|
|
|
|
|
|
|
RSCR |
Yes |
Yes |
|
|
Yes |
|
|
|
|
|
|
CSIR |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|
|
CSCR |
Yes |
Yes |
|
Yes |
Yes |
|
|
|
|
|
|
Motor Starting Torque Classification
Type |
Description |
Low Starting Torque
LST For RSIR/RSCR motor in LBP / HBP model Suitable for capillary application
High Starting Torque
HST For CSIR/ CSCR motor in LBP / HBP model Suitable for expansion valve application
* LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already agreed.