Whirlpool W10254447B, W10254448A-SP User Manual

0 (0)

WASHER INSTALLATION

INSTRUCTIONS

Table of Contents

 

WASHER SAFETY..........................................................

1

INSTALLATION REQUIREMENTS................................

2

Tools and Parts................................................................

2

Location Requirements...................................................

2

Drain System....................................................................

4

Electrical Requirements..................................................

5

INSTALLATION INSTRUCTIONS..................................

5

Connect Drain Hose........................................................

6

Connect Inlet Hoses........................................................

7

Level Washer....................................................................

8

Complete Installation Checklist.....................................

9

INSTRUCTIONS

 

D’INSTALLATION

 

DE LA LAVEUSE

 

Table des matières

 

Sécurité de la laveuse.......................................

10

EXIGENCES D’INSTALLATION...................................

10

Outillage et pièces.........................................................

10

Exigences d’emplacement............................................

11

Système de vidange......................................................

13

Spécifications électriques.............................................

13

INSTRUCTIONS D’INSTALLATION.............................

14

Raccordement du tuyau de vidange............................

15

Raccordement des tuyaux d’arrivée d’eau..................

16

Établissement de l’aplomb de la laveuse....................

17

Liste de vérification pour l’achèvement

 

de l’installation...............................................................

19

Para obtener acceso al instrucciones de instalación en español, o para obtener información adicional acerca de su producto, visite: www.whirlpool.com

INSTALLATION NOTES

NOTES SUR L’INSTALLATION

Date of purchase:_________________________________

Date d’achat :____________________________________

Date of installation:_ _______________________________

Date d’installation :_ _______________________________

Installer:_________________________________________

Installateur :______________________________________

Model number:____________________________________

Numéro de modèle :________________________________

Serial number:____________________________________

Numéro de série :__________________________________

Washer Safety

W10254447B

W10254448A-SP

INSTALLATION REQUIREMENTS

Tools and Parts

Optional tools:

Gather required tools and parts before starting installation.

Tools needed:

Flashlight

Bucket

Adjustable or open end

 

Level

wrenches 12" (13 mm) and

 

 

 

 

 

 

916" (14 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4" min

 

 

 

 

 

 

 

 

(102 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wood block

Ruler or measuring tape

 

 

 

 

Pliers that open to 1916" (39.5 mm)

Parts supplied:

NOTE: All parts supplied for installation are in the washer basket.

Available Accessories:

An optional matching pedestal is available for your washer. Please contact your retailer for ordering information, or see the Assistance or Service page on the back of your Use and Care Guide.

Alternate parts: (Not supplied with washer)

Your installation may require additional parts. To order, please refer to toll-free numbers on the back page of your Use and Care Guide.

If you have:

You will need:

Overhead sewer

Standard 20 gal. (76 L) 39" (990 mm)

 

tall drain tub or utility sink, sump

 

pump and connectors (available from

 

local plumbing suppliers)

1" (25 mm) standpipe

2" (51 mm) diameter to 1" (25 mm)

 

diameter Standpipe Adapter

 

Part Number 3363920

 

Connector Kit Part Number 285835

Drain hose too short

Extension Drain Hose Part

 

Number 285863

 

Connector Kit Part Number 285835

Lint clogged drain

Drain Protector Part Number 367031

 

Connector Kit Part Number 285835

Floor drain system

Siphon Break Kit Part Number 285834

 

Connector Kit (x2) Part Number 285835

 

Extension Drain Hose Part

 

Number 285863

Cable tie

Drain hose with clamp and form (may be shipped unassembled)

Alternative Inlet Hoses:

 

(may be required for some installations, not supplied

Inlet hoses (2) with

with washer)

 

washers

n 8212656RP

10 ft. (3.0 m) Inlet hose, Black EPDM (2 pack)

 

 

n 8212641RP

5 ft. (1.5 m) Inlet hose, Black EPDM (2 pack)

 

n 8212546RP

4 ft. (1.2 m) Inlet hose, Black EPDM (2 pack)

 

n 8212545RP

5 ft. (1.5 m) Inlet hose, Red and Blue EPDM

 

 

(2 pack)

 

n 8212487RP

5 ft. (1.5 m) Nylon braided inlet hose (2 pack)

Transport bolt hole

n 8212638RP

6 ft. (1.8 m) Nylon braided inlet hose, space

plugs (4)

 

saving 90° elbow, hypro-blue steel couplings

 

 

(2 pack)

n 8212637RP 6 ft. (1.8 m) Inlet hose, Black EPDM, space saving 90° elbow, hypro-blue steel couplings (2 pack)

2

LOCATION REQUIREMENTS

Proper installation is your responsibility.

You will need:

nA water heater set to 120° F (49° C).

nA grounded electrical outlet located within 6 ft (1.8 m) of power cord on back of washer.

nHot and cold water faucets located within 4 ft (1.2 m) of hot and cold water fill valves on washer, and water pressure of 20-100 psi (137.9-689.6 kPa).

nA level floor with maximum slope of 1" (25 mm) under entire washer. Installing on carpet or surfaces with foam backing is not recommended.

nFloor must support washer’s total weight (with water and load) of 315 lbs (143 kgs).

IMPORTANT: Do not install, store or operate washer where it will be exposed to weather or in temperatures below 32° F

(0° C). Water remaining in washer after use may cause damage in low temperatures. See “Washer Care” in Washer Use and Care Guide for winterizing information.

27" 51" (686 mm)

(1295 mm)

38" (965 mm)

1/2" - 1"

(13 mm - 25 mm)

1/2"

mm)

All dimensions show recommended spacing allowed, except for closet door ventilation openings which are the minimum required.

For each arrangement, consider allowing more space for ease of installation and servicing, and spacing for companion appliances and clearances for walls, doors, and floor moldings.

Space must be large enough to allow door to fully open. Add spacing of 1" (25 mm) on all sides of washer to reduce

noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.

Recessed area or closet installation (stacked washer and dryer):

6" (152 mm)

 

 

3"

 

 

 

(76 mm)

48 in.2

 

 

 

 

 

771/2"

(310 cm2)

 

 

 

 

 

(1969 mm)

 

 

 

 

24 in.2

5"

 

3"

(155 cm2)

(127 mm)

 

 

 

(76 mm)

 

 

 

 

 

 

1"

 

 

1"

(25 mm)

 

 

 

 

 

(25 mm)

 

 

Recessed area or closet installation (washer only):

3" (76 mm)

48 in.2

(310 cm2)

 

24 in.2

4"

(155 cm2)

3"

(102 mm)

(76 mm)

 

1" 1" (25 mm)

(25 mm)

Custom cabinet installation:

7" (178 mm)

Custom under counter installation:

14"

 

 

(356 mm)

 

39" min.

 

 

(990 mm)

 

 

 

4"

 

 

(102 mm)

 

1"

 

1"

(25 mm)

1"

(25 mm)

 

 

 

(25 mm)

 

3

DRAIN SYSTEM

Drain system can be installed using a floor drain, wall standpipe, floor standpipe, or laundry tub. Select method you need.

IMPORTANT: To avoid siphoning, only 412" (113 mm) of drain hose should be inside standpipe. Always secure drain hose with cable tie.

Floor standpipe drain system

41/2" (113 mm)

Laundry tub drain system

41/2"

(113 mm)

min.

30"

(762 mm)

Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at least 30" (762 mm) above floor; install no higher than 96" (2.44 m) from bottom of washer.

Minimum diameter for a standpipe drain: 2" (51 mm). Minimum carry-away capacity: 17 gal. (64 L) per minute. A 1/4" (6 mm) diameter to 1" (25 mm) diameter Standpipe Adapter Kit is available (Part Number 3363920). Top of standpipe must be at least 30" (762 mm) high; install no higher than 96" (2.44 m) from bottom of washer. If you have an overhead sewer and need to pump higher than 96 inches, a sump pump and associated hardware are needed. See “Alternative Parts”.

Wall standpipe drain system

41/2"

(113 mm)

See requirements for floor standpipe drain system.

Floor drain system

Floor drain system requires a Siphon Break Kit (Part Number 285834), 2 Connector Kits (Part Number 285835), and an Extension Drain Hose (Part Number 285863) that may be purchased separately. See “Alternative Parts”. Minimum siphon break height: 28" (710 mm) from bottom of washer. (Additional hoses may be needed.)

4

ELECTRICAL REQUIREMENTS

INSTALLATION INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

nA 120 volt, 60 Hz., AC only, 15or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit breaker serving only this appliance be provided.

nThis washer is equipped with a power supply cord having a 3 prong grounding plug.

nTo minimize possible shock hazard, the cord must be plugged into a mating, 3 prong, grounding-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician.

nIf codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

nDo not ground to a gas pipe.

nCheck with a qualified electrician if you are not sure the washer is properly grounded.

nDo not have a fuse in the neutral or ground circuit.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected washer:

This washer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by providing a path of least resistance for electric current. This washer is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded.

Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

For a permanently connected washer:

This washer must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

NOTE: To avoid floor damage, set washer onto cardboard before moving it.

1. Move washer

36"

(914 mm)

It is necessary to remove all shipping materials for proper operation and to avoid excessive noise from washer.

Move washer to within 4 ft (1.2 m) of its final location. It must be in a fully upright position.

2. Locate transport bolts

Locate four transport bolts on rear of washer.

5

Whirlpool W10254447B, W10254448A-SP User Manual

3. Remove transport bolts from washer

Loosen bolts with a 13 mm (1/2") wrench. Slide each bolt and spacer to center of hole. Pull bolts and plastic spacers from back of washer. Discard bolts and spacers.

4. Cover bolt holes with transport bolt hole plugs

Close bolt holes on cabinet back with four transport bolt hole plugs included with washer parts.

5. Remove power cord

Pull power cord through opening in rear panel and close hole with attached cap.

NOTE: If washer is transported at later date, call your local service center to avoid suspension and structural damage, a certified technician must properly set up washer for relocation.

6. Place power cord over top

Remove the yellow shipping strap from the cord. Gently place power cord over top of washer to allow free access to back of washer.

IMPORTANT: Do not plug washer in until installation has been completed.

Connect Drain Hose

7. Attach drain hose to drain port

Ribs

If clamp is not already in place on elbow end of drain hose, squeeze clamp with pliers and slide it over end of hose, centering it between the ribs, as shown. Squeeze clamp with pliers and slide elbow end of drain hose onto drain port and secure with clamp.

For a laundry tub or standpipe drain, go to step 9.

For a floor drain, remove the preinstalled drain hose form as shown in Step 8. You may need additional parts with separate directions. See “Alternative Parts”.

6

Loading...
+ 14 hidden pages