Whirlpool UXT4830AA, UXT4836AA User Manual

0 (0)
Whirlpool UXT4830AA, UXT4836AA User Manual

Range Hood - 30" (76.2 cm) and 36" (91.4 cm)

PRODUCT MODEL NUMBERS

UXT4830AA

UXT4836AA

Electrical: A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

CABINET OPENING DIMENSIONS

30" (76.2 cm) or 36" (91.4 cm) min. cabinet opening width

18"(45.7 cm) min.

24" (61.0 cm) suggested max. bottom of cabinet to cooking surface

13" (33.0 cm) cabinet depth

18" (45.7 cm) min. clearance upper cabinet to countertop

36" (91.4 cm) base cabinet height

OVERALL DIMENSIONS

 

1 ¹⁄ "

 

12"

(3.8 cm)

1"

 

(30.5 cm) 9"

 

 

(2.5 cm)

(22.9 cm)

2"

 

 

 

 

(5.1 cm)

 

6"

 

 

(15.2 cm)

 

 

³⁄ "

 

 

(1.9 cm)

 

1¹⁄ "

 

 

 

 

(3.8 cm)

 

7 ¹⁄ "

³⁄ "

 

(9.5 mm)

 

(19.1 cm)

 

 

29 ⁄ " (75.9 cm) - 30" (76.2 cm) model

35 ⁄ " (91.1 cm) - 36" (91.4 cm) model 17 ¹⁄ " (44.5 cm)

VENTING REQUIREMENTS

Roof Venting

A

D

B

 

C

 

A.7" (17.8 cm) round vent or a 3¹⁄ " x 10" (8.3 x 25.4 cm) vent through roof

B.Round vent: use 7" (17.8 cm) round damper

(purchased separately)

C.18" (45.7 cm) - 24" (61.0 cm) above cooking surface

D.Roof cap

Wall Venting

A

 

B

D

 

C

 

A. 7" (17.8 cm) round vent or a

3¹⁄ " x 10" (8.3 x

25.4 cm) vent

through the wall

 

B. 3¹⁄ " x 10" (8.3 x

25.4 cm)

through the wall

 

C.18" (45.7 cm) - 24" (61.0 cm) above cooking surface

D.Wall cap

x 10" (8.3 x 25.4 cm) vent system

7" (17.8 cm) vent system

x 10"

(8.3 x 25.4 cm) elbow

6 ft. ( 1.8 m)

 

 

 

 

wall cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum length

=

35 ft.

(10.7 m)

 

 

 

 

1 - 90° elbow

 

=

5 ft.

(1.5 m)

 

 

 

 

8 ft. (2.4 m) straight

=

8 ft.

(2.4 m)

 

 

 

 

 

2

ft.

1 - wall cap

 

=

0 ft.

(0 m)

 

(0.6 m)

Length of

x

 

 

 

 

 

 

 

10" (8.3 x 25.4 cm) system

= 13 ft.

(3.9 m)

 

 

 

 

NOTE: Flexible vent is not recommended

90˚ elbow

2 ft

(0.6 m)

Wall cap

6 ft (1.8 m)

Maximum length

= 35 ft.

(10.7 m)

1 - 90° elbows

=

5 ft.

(1.5 m)

8 ft. (2.4 m) straight

=

8 ft.

(2.4 m)

1 - wall cap

=

0 ft.

(0 m)

Length of 7"

 

 

(3.9 m)

(17.8 cm) system

= 13 ft.

NOTE: Flexible vent is not recommended

x 10" (8.3 x 25.4 cm) vent system

7" (17.8 cm) vent system

 

 

 

 

 

 

 

x 10"

x 10"

x 10"

90° elbow =

45° elbow =

7" (17.8 cm)

x 10"

x 10"

5 ft. (1.5 m)

2.5 ft. (0.8 m)

wall cap =

(8.3 x 25.4 cm) to

(8.3 x 25.4 cm)

(8.3 x 25.4 cm)

(8.3 x 25.4 cm)

(8.3 x 25.4 cm)

 

 

0 ft. (0 m)

7" (17.8 cm) =

to 7" (17.8 cm)

90° elbow =

flat elbow =

wall cap =

 

 

 

4.5 ft. (1.4 m)

90° elbow =

5 ft. (1.5 m)

12 ft. (3.7 m)

0 ft. (0 m)

 

 

 

 

5 ft. (1.5 m)

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10240580A

Instructions packed with product. Specifications subject to change without notice.

07-30-09

Loading...