PWS-1K68A-1R 1600W 1U Redundant Power Supply Specification
• Dimension (W x L x H): |
76 x 360 x 40 mm |
|
• Maximum Output Power: 1600W / 800W |
||
|
|
|
INPUT CHARACTERISTICS |
|
|
|
|
|
RATED VOLTAGE / |
100-140Vac / 10 - 7A |
|
CURRENT |
180-240Vac / 11 – 8A |
|
RATED FREQUENCY |
50-60HZ |
|
INRUSH CURRENT |
Less than 30A |
|
POWER FACTOR |
0.98 @ max load (Typical) |
|
|
|
|
|
|
|
DC OUTPUT CHARACTERISTICS |
|
|
|
|
|
MAXIMUM POWER |
800W @ 100-140Vac |
|
|
1600W @ 200-240Vac |
|
EFFICIENCY |
80Plus Titanium |
|
|
Typical 96%+ @ 230Vac |
|
VOLTAGE |
+12V |
+5Vsb |
MAXIMUM CURRENT |
133A (1600W) |
1A |
|
66A (800W) |
|
REGULATION |
+/- 5% |
+/- 5% |
RIPPLE & NOISE |
120mV |
50mV |
OUTPUT CONNECTOR |
Gold Finger (27 pair connector) |
|
HOLD UP TIME |
PWOK 10ms at 75% of max Loading |
|
|
12V 11ms at 75% of max loading |
|
|
|
|
|
|
|
GENERAL SPECIFICATIONS |
|
|
|
|
|
REMOTE MANAGEMENT |
PMBus 1.2 Compatible |
|
|
FRU Data |
|
MTBF |
>200,000hours at 25 °C |
|
REDUNDANCY |
Hot swappable, N+1 |
|
LEAKAGE CURRENT |
<1.9mA@264Vac for single PSU |
|
PROTECTION |
OCP, OVP, Short Circuit, Over |
|
|
Temperature, Input Under Voltage |
|
|
|
|
Features and Benefits:
•Titanium 96%+ Efficiency
•PMBus 1.2 Support for Remote Management
•Flexible Redundancy Control
REGULATORY |
|
|
|
SAFETY COMPLIANCE |
UL60950-1/CSE 60950-1 |
|
EN60950-1 |
|
IEC60950-1 |
|
CB Report |
|
CE Low Voltage Directive |
|
BSMI |
|
CCC (GB17625.1-2013) (China) |
EMC |
EMI Class A |
|
|
|
|
ENVIRONMENTAL SPECIFICATIONS |
|
|
|
AMBIENT |
Operating: 0 to 50 °C |
TEMPERATURE |
Non-Operating: -10 to 60 °C |
OPERATING |
Operating: to 5000m |
ALTITUDE |
Non-Operating: to 10580m |
RELATIVE HUMIDITY |
Operating: 20% to 90% |
|
(non-condensing) |
|
Non-Operating: 5% to 95% |
|
(non-condensing) |
|
|
Disclaimer: Specification is subject to change without prior notice