NEW
Variable Refrigerant Flow (VRF), Multi-Zone,
Heat Pump & Heat Recovery Systems
ECOiEX_ctlg_2015_rc.indd 1 |
1/15/15 12:02 PM |
Panasonic Delivers
Eco-Friendly Air Solutions
In any indoor environment, eco-friendly air conditioning plays a vital role in maintaining our health, comfort, and productivity. Whether it’s an office, a hotel, or a shopping mall, every building matters. That's why Panasonic has developed energy-efficient large-scale air conditioning solutions to suit a variety of business applications.
As one of the pillars of Panasonic’s B2B operations, our air conditioning sector provides comprehensive solutions to businesses around the world. Harnessing our advanced technology and extensive on-site expertise, we serve clients in a diverse range of environments throughout the world.
Panasonic air conditioning solutions are designed from the ground up to meet the specific needs of each location, whilst placing a premium on efficiency and reliability. At every stage, we seek to make optimal use of resources and energy to create solutions that benefit the environment.
ECOi™ VRF System Your Building Life Tool.
ECOi™ has a number of diverse features to meet all your conditioning needs, including: flexible combinations: ECOi™ allows multiple indoor unit combinations that provide you with the utmost in flexible solutions. The system also allows multiple unit connectivity providing up to 150%* of the total capacity of the condensing unit. This provides 14-29 indoor units connected to one condensing unit (6-12 tons).
Inverter Control Compressor: All ECOi™ systems utilize highly advanced inverter controlled compressor technology. By varying the rotational speed of the compressor, the inverter control can precisely match the amount of refrigerant being delivered to the needs of each zone. This intelligent approach helps realize excellent efficiencies during partial-load conditions.
This allows all occupants to enjoy consistent room temperature, regardless of any increases or decreases in the heat load during the day. ECOi™ quite simply knows what you need, and when you need it throughout the day.
And even better, it does so with energy efficiency in mind.
Lower running and life cycle costs: Panasonic ECOi™ VRF systems are amongst the most efficient systems on the market, offering COPs in excess of 4.0 at full load conditions.
All Panasonic VRF systems are designed to maximize the reduction of running cost by using our unique intelligent control sequence. This is done by the most efficient combination of compressor, fan, and refrigeration management criteria. Improved defrost sequencing reduces running cost and defrost cycle.
*Exceptions apply when using Vertical Air Handlers.
Panasonic Worldwide Air Solutions
Australia Travelodge Hobart |
Spain Hotel Claris 5 GL |
HongKong King Yip Road |
Malaysia Gapruna project |
Cooling Capacity: |
Cooling Capacity: |
Cooling Capacity: |
Cooling Capacity: |
302 kW / 86 USRT |
769 kW / 218 USRT |
2,108 kW / 599 USRT |
5,370 kW / 1,526 USRT |
2
ECOiEX_ctlg_2015_rc.indd 2 |
1/15/15 12:02 PM |
The milestones of Panasonic Airconditioning in the US.
1958
1983
1998
2001
2003
2006
2013
2014
Started production and sales in May under the “Home Cooler” name.
Panasonic has launched ductless A/C to US market and has been leading A/C market.
Introduced revolutionary Gas Heater Air Conditioner 14KGS11.
That maintains a consistent heating performance level, regardless of how much the ambient temperature goes down outside.
Launched VRF "Eco-Multi" to the US market.
Eco-Multi was displayed at the AHR show, and was introduced to other ductless manufacturers.
It's the new individual air-conditioning system that effectively combines a power control compressor and an electronic refrigerant control valve.
First R410a driven ductless model, 24KS62R, was introduced meeting the 2006 DOE regulation.
Again, blazed a trail to other ductless manufacturers.
Refreshed the total ductless line, introducing its proven Inverter technology to the US market.
Celebrating the 30th anniversary of marketing in the USA.
Introduce EXTERIOS series to US market
SEER 28.5 Highest Efficient model in Industry as of 2013/March
Introduced All Inverter Driven 2way VRF "ECO-EX" & System 5
Heating Operation Schematic
|
On/Off Valve 2 |
|
Compressor |
|
|
Orifice |
|
|
|
|
Unsealed Circuit |
|
Check |
Reversing |
|
|
Valve 2 |
||
|
|
|
Valve |
|
|
|
|
|
|
|
Valve 1 |
Heater |
|
Outdoor |
|
On/Off |
Refrigerant |
Exchanger |
|
|
|
|||
Indoor Unit |
Check Valve 1 Burner |
|
|
Heat |
Capillary Tube |
|
|
|
United States Shippensburg University |
China Star River Group Luxury Condominium |
Russia Innovation Center of Novosibirsk Academy |
Siberia Sun City |
Cooling Capacity: |
Cooling Capacity: |
Cooling Capacity: |
Cooling Capacity: |
1,498 kW / 426 USRT |
16,737 kW / 4,755 USRT |
1,487 kW / 422 USRT |
1,605 kW / 456 USRT |
3
ECOiEX_ctlg_2015_rc.indd 3 |
1/15/15 12:02 PM |
INDOOR UNITS LINE-UP
Panasonic introduced its first VRF to the US market in 2001 with 16 different indoor units.
Since then, it has continued to refine and expand VRF indoor model offerings, and today the model line up totals up to 49 models.
In 2015, Panasonic is replacing some indoor units with more sophisticated designs with better efficiencies. These new indoor models are also connectable to Panasonic original “ECONAVI” (optional).
Whether it's an office, a hotel, or other applications, Panasonic offers wide selections in solving your air conditioning requirements.
|
Nominal Cooling Capacity |
|
|
|
|
|
|
|
Btu/h class |
7,500 |
9,000 |
12,000 |
15,000 |
18,000 |
24,000 |
Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MK2 TYPE |
|
|
|
|
|
|
|
|
|
|
NEW |
|
|
|
|
|
S-18MK2U6 |
|
|
Wall Mounted |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
||
|
(Optional Accessory) |
S-07MK2U6 |
S-09MK2U6 |
S-12MK2U6 |
|
S-19MK2U6* |
S-24MK2U6 |
||
|
|
|
|
|
(Special Order)* |
* |
|||
|
|
|
|
|
|
|
|
||
MY2 TYPE |
|
|
|
|
|
|
|
|
|
4-way Mini Ceiling |
|
NEW |
|
|
|
|
|
|
|
Cassette |
|
|
|
|
|
|
|
|
|
24" x 24" |
(Optional Accessory) |
|
|
S-12MY2U6 |
|
S-18MY2U6 |
|
||
|
|
|
|
|
|
|
|
||
MU2 TYPE |
|
|
|
|
|
|
|
|
|
4-way Ceiling |
|
NEW |
|
|
|
|
|
|
|
Cassette |
|
|
|
|
|
|
|
|
S-24MU2U6* |
33" x 33" |
(Optional Accessory) |
|
|
|
|
|
|||
MD TYPE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 Way Ceiling |
|
|
|
|
|
|
|
|
|
Cassette |
|
|
|
S-07MD1U6 |
S-09MD1U6 |
S-12MD1U6 |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
MF2 TYPE |
|
|
|
|
|
|
|
|
|
|
NEW |
|
|
|
|
|
|
||
Concealed Duct – |
|
|
|
|
|
|
|
|
|
Medium Static |
(Optional Accessory) |
S-07MF2U6 |
S-09MF2U6 |
S-12MF2U6 |
S-15MF2U6 |
S-18MF2U6 |
S-24MF2U6 |
||
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
MM2 TYPE |
|
|
|
|
|
|
|
|
|
|
NEW |
|
|
|
|
|
|
||
Concealed Duct – |
|
|
|
|
|
|
|
|
|
Low Static Pressure |
(Optional Accessory) |
S-07MM2U6 |
S-09MM2U6 |
S-12MM2U6 |
S-15MM2U6 |
S-18MM2U6 |
|
||
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
ME TYPE |
|
|
|
|
|
|
|
|
|
Concealed Duct –Medium-High Static |
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MT2 TYPE |
|
NEW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ceiling Suspended |
(Optional Accessory) |
|
|
S-12MT2U6* |
|
S-18MT2U6* |
S-24MT2U6* |
||
|
|
|
|
|
|
|
|||
MP TYPE |
|
|
|
|
|
|
|
|
|
Floor Mounted |
|
|
|
|
|
|
|
|
|
without decorative panel |
S-07MP1U6 |
S-09MP1U6 |
S-12MP1U6 |
S-15MP1U6 |
S-18MP1U6 |
S-24MP1U6 |
|||
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
MR TYPE |
|
|
|
|
|
|
|
|
|
Floor Mounted |
|
|
|
|
|
|
|
|
|
without decorative panel |
S-07MR1U6 |
S-09MR1U6 |
S-12MR1U6 |
S-15MR1U6 |
S-18MR1U6 |
S-24MR1U6 |
|||
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
MVA TYPE |
|
|
|
|
|
|
|
|
|
Vertical Air Handler |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MVA18FBAS6HBCP |
MVA24FBAS6HBCP |
*Available from late 2015
4
ECOiEX_ctlg_2015_rc.indd 4 |
1/15/15 12:03 PM |