1⁄4 DIN pH, ORP, and Conductivity Controllers and Transmitters
PHUCN601
UFor pH, ORP, Conductivity/Resistivity
U1⁄4 DIN, NEMA 4X (IP66), Polycarbonate Enclosure
UUser-Friendly Design with Interior LCD Menu
UEasy to Read with Large, Bright LED Display
UQuick and Easy to Calibrate
UReduces Chemical Consumption
with Cycle-Timed Relays on Controller
UTwo Control Relays with Third Relay for High/Low Alarm on Controller
The PHUCN600 Series multi-parameter controller is a microprocessor-based controller capable of measuring pH, ORP, or conductivity.
There are two displays on the PHUCN600 Series: a bright LED numeric display with bar graph on the outside front panel, and a 2-line, 16-character LCD display on the inside. The LED readout on the outside panel can be seen several yards away. The distinctive, color-coded bar graph will immediately indicate if you are within the process parameters that you set (green), if the control relays are on (yellow), and if you are in alarm condition (red). This makes diagnosing pump and alarm malfunctions easy. All configuration and control functions are performed on the LCD menu on the inside front panel.
A universal mounting kit is included for surface, panel, and pipemount applications. The ¹⁄ DIN enclosure makes panel-mount cutouts and engineering simple.
Complete and versatile, the PHUTX600 is a ¹⁄ DIN two-wire transmitter, which can measure conductivity, pH, or ORP. The PHUTX600 comes complete with a universal mounting kit for surface, panel, and pipe-mount applications. The NEMA 4X (IP66) ¹⁄ DIN enclosure is perfect for stand-alone or panel-mount operation.
PHUCN600 and PHUTX600 Series are packaged in a rugged NEMA 4X (IP66) polycarbonate enclosure, making them ideally suited for heavy-duty applications such as industrial wastewater neutralization, municipal water and wastewater, pulp and paper, and process control.
When the PHUCN600 Series is powered up for the first time,
it will display the meter selection screen where the meter type is selected. This meter selection screen will only be displayed when the PHUCN600 Series is powered up for the first time.
After the user selects a meter type, the PHUCN600 Series will remain set to that meter type until it is changed with the meter selection menu function in the Utilities menu.
To return the PHUCN600 Series to its factory settings, the user re-selects the current meter type from the meter selection menu function. This will override all setpoints and return all settings to the factory settings.
The PHUCN600 Series User’s menu has been divided into five main categories:
•Calibration, used to calibrate the PHUCN600 Series with the selected sensor
•Utilities, used to manually control or override the outputs
•Setup, used to configure the PHUCN600 Series’ many options
•Diagnostics, used to troubleshoot any problems
•Outputs, used to configure the PHUCN600 Series outputs
D-X |
For Sales |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
& Service |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
U.S.A. and Canada
PHUCN601 Enclosure dimensions: mm (inches)
MOUNTING
BRACKET
91 (3.60)
|
MINIMUM |
|
|
|
|
INTERIOR |
|
|
|
|
CLEARANCE |
91 |
|
|
|
FOR PANEL |
|
|
|
|
MOUNTING |
(3.60) |
|
|
|
162 (6.37) |
|
|
|
|
|
PANEL CUTOUT |
|
|
|
97 |
|
|
|
|
(3.80) |
|
|
|
TOP VIEW |
|
|
|
|
|
|
184 |
|
|
|
|
(7.23) |
7.0 |
|
|
|
|
64 |
|
|
|
145 |
(0.26) |
|
|
|
(2.5) |
||
|
|
4 PLACES |
||
|
|
(5.70) |
|
|
|
|
|
|
|
|
PHUCN601 |
|
|
|
ALARM |
3.80 |
29 |
5.0 |
117 |
RELAY B |
(0.20) |
|||
|
(97) |
(1.15) |
(4.63) |
|
RELAY A |
4 PLACES |
|||
ALARM |
|
|
|
|
|
TEMP |
|
|
|
CAL |
UP DOWN ENTER |
|
|
|
|
|
1⁄2 CONDUIT HOLES |
|
|
|
|
4 PLACES |
|
|
FRONT VIEW |
128 |
10 |
MOUNTING |
|
|
|
(5.05) |
(0.38) |
BRACKET |
SIDE VIEW
PHUCN601 inside shown smaller than
Mounting
PANEL MOUNT |
SURFACE MOUNT |
SPECIFICATIONS FOR PHUCN600 AND PHTX600 SERIES
|
pH |
ORP |
Conductivity |
Display, PHUCN600/610 Series |
Front Panel: 4 x 7 segment 12.7 mm (1⁄2") LED display, 1 LED indicator online, 7 LED bar graph |
||
|
Inside Panel: 2 x 16 alpha-numeric LCD display |
|
|
Display, PHUTX600 |
2 x 16 alpha numeric LCD display |
|
|
Power, PHUCN600/610 Series |
120 or 240 Vac 50/60 Hz (less than 12 VA) |
|
|
Power, PHUTX600 |
4 to 20 mA loop-powered 16 to 32 Vdc |
|
|
Measuring Range |
0.01 to 14.00 pH |
-1999 to 1999 mV |
µS/cm3: 0 to 2.000, |
|
-5 to 95°C |
-5 to 95°C |
0 to 20.00, 0 to 200.0, 0 to 2000, |
|
(23 to 203°F) |
(23 to 203°F) |
mS/cm: 0 to 20.00, 0 to 200.0 |
|
|
|
MΩ/cm: 0 to 19.99 |
|
|
|
0 to 100°C (32 to 212°F) |
Temperature Compensation |
Automatic or manual, |
Not required |
Automatic or manual; |
|
-5 to 95°C (23 to 203°F) |
|
User-selectable temperature |
|
|
|
compensation slope 0.0 to 10.0%/°C. |
|
|
|
0 to 100°C (32 to 212°F). |
Temperature Units |
°C or °F, selectable |
|
|
Temperature Sensor |
User selectable: 300 Ω NTC thermistor, 3000 Ω NTC thermistor or Pt. 1000 RTD |
||
Calibration Modes |
Auto-calibration |
Manual calibration |
Dry calibration |
|
Manual calibration |
Temperature |
Sample calibration |
|
Temperature calibration |
calibration |
Temperature calibration |
Ambient Conditions |
-20 to 60°C (-4 to 140°F), 0 to 90% RH (non-condensing) |
|
|
Menu Access Front Panel |
Auto-calibration |
Manual calibration |
Dry calibration |
|
Manual calibration |
Temperature calibration |
Sample calibration |
|
Temperature display |
|
Temperature calibration |
Menu Access Inside Panel |
Full Access to all parameters of operations menu |
|
|
Sensor to Transmitter Distance |
Differential Sensor: 914 m (3000') |
914 m (3000') |
91 mm (300') |
|
Combination Sensor: 3.0 m (10') |
3.0 m (10') |
3.0 m (10') |
Relay Outputs |
Two Control Relays: 10 A/NO, 5 A/NC @ 240 Vac or 28 Vdc. |
|
|
for PHUCN600/610 Series |
Mode: Process control; adjustable parameters: process direction, (rising or falling) on-setpoint, |
||
|
off setpoint, (0 to 100% of full scale), cycle timer (on/off, 0 to 600 seconds), failsafe (on/off). |
||
|
One Alarm Relay: 10 A/NO, 5 A/NC @ 240 Vac or 28 Vdc. |
|
|
|
Mode: high/low alarm; adjustable parameters: low on/low off setpoint (0 to 100% of full scale, |
||
|
low on must be less than low off), high on/high off setpoint (0 to 100% of full scale, high on must |
||
|
be greater than high off). |
|
|
Analog Outputs |
4 to 20 mA channel 1 isolated output, range expand 0 to 100% of full scale |
||
|
(min segment 10% of full scale), max load 800 V |
|
|