GRAPHIC OPERATION TERMINAL
MODEL
GT1055-QSBD GT1050-QBBD
QUICK START MANUAL
Mitsubishi Electric Automation, Inc.
GT105_ QUICK START MANUAL |
|
|
1. INTRODUCTION................................................................. |
3 |
|
1.1 CAUTION........................................................................... |
3 |
|
1.2 CERTIFICATION................................................................ |
4 |
|
1.3 INCLUDED ITEMS ............................................................ |
5 |
|
2. SPECIFICATIONS.............................................................. |
5 |
|
2.1 |
MODEL NAME EXPLANATION......................................... |
5 |
2.2 |
GENERAL SPECIFICATIONS........................................... |
5 |
2.3 |
PERFORMANCE SPECIFICATIONS................................ |
5 |
2.4 |
POWER SUPPLY SPECIFICATIONS................................ |
6 |
3. HARDWARE SPECIFICATIONS................................... |
6 |
|
4. EXTERNAL DIMENSIONS.............................................. |
7 |
|
5. RATING PLATE................................................................... |
7 |
|
6. INSTALLATION AND REMOVAL.................................. |
7 |
|
6.1 |
CONTROL PANEL INSIDE DIMENSIONS FOR |
|
|
MOUNTING GOT............................................................... |
7 |
6.2 |
PANEL CUTTING DIMENSIONS....................................... |
8 |
6.3 |
MOUNTING POSITION..................................................... |
8 |
6.4 |
CONTROL PANEL INSIDE TEMPERATURE |
|
|
AND MOUNTING ANGLE.................................................. |
8 |
6.5 |
INSTALLATION PROCEDURE.......................................... |
8 |
7. WIRING................................................................................... |
9 |
|
7.1 POWER SUPPLY WIRING................................................. |
10 |
|
7.2 WIRING INSIDE AND OUTSIDE THE PANEL................... |
11 |
|
8. OPERATION SETTINGS................................................ |
11 |
|
8.1. BATTERY......................................................................... |
11 |
|
8.2 |
UTILITY FUNCTION........................................................ |
11 |
8.3 |
UTILITY DISPLAY............................................................ |
12 |
8.4 |
COMMUNICATION INTERFACE SETTING..................... |
13 |
8.5 |
DATA TRANSFER............................................................ |
16 |
8.6 |
COMMUNICATION MONITOR........................................ |
16 |
8.7 |
DISPLAY SETTINGS....................................................... |
17 |
8.8 |
OPERATION SETTING .................................................. |
19 |
8.9 |
CLOCK SETTINGS AND BATTERY STATUS DISPLAY..20 |
|
9. MAINTENANCE AND INSPECTION......................... |
21 |
|
9.1 |
DAILY INSPECTION........................................................ |
21 |
9.2 |
PERIODIC INSPECTION................................................ |
22 |
9.3 |
CLEANING METHOD...................................................... |
22 |
10. WARRANTY..................................................................... |
23 |
2
Mitsubishi Electric Automation, Inc.
This manual describes the specifications of the product. Before use, read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions. And, store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are the Registered trademarks or trademarks of each company.
Effective April 2015
Specifications are subject to change without notice. © 2008 MITSUBISHI ELECTRIC CORPORATION
Safety Precaution (Read these precautions before use.) This manual classifies the safety precautions into two categories: DANGER and
CAUTION.
DANGER Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
CAUTION Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Depending on the circumstances, procedures indicated by CAUTION may also cause severe injury. It is important to follow all precautions for personal safety.
DANGER DESIGN PRECAUTIONS
•Some failures of the GOT or cable may keep the outputs on or off. An external monitoring circuit should be provided to check for output signals which may lead to a serious accident. Not doing so can cause an accident due to false output or malfunction.
•If a communication fault (including cable disconnection) occurs during monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative. A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur. Not doing so can cause an accident due to false output or malfunction.
•Do not use the GOT as the warning device that may cause a serious accident. An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning. Failure to observe this instruction may result in an accident due to incorrect output or malfunction.
•Incorrect operation of the touch switch(s) may lead to a serious accident if the GOT backlight is gone out. When the GOT backlight goes out, causes the monitor screen to appear blank, while the input of the touch switch(s) remains active. This may confuse an operator in thinking that the GOT is in “screensaver” mode, who then tries
to release the GOT from this mode by touching the display section, which may cause a touch switch to operate.
CAUTION DESIGN PRECAUTIONS
•Do not bundle the control and communication cables with maincircuit, power or other wiring. Run the above cables separately from
GT105_ QUICK START MANUAL
such wiring and keep them a minimum of 100mm (3.94 in.) apart. Not doing so noise can cause a malfunction.
•Do not press the GOT display section with a pointed material as a pen or driver. Doing so can result in a damage or failure of the display section.
•Before connecting to GOT, turn ON the controller to enable the communication. When the communication of controller is not available, a communication error may occur in GOT.
DANGER MOUNTING PRECAUTIONS
•Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel. Not doing so can cause the unit to fail or malfunction.
•When installing the battery wear an earth band etc. to avoid the static electricity. The static electricity can cause the unit to fail or malfunction.
CAUTION MOUNTING PRECAUTIONS
•Use the GOT in the environment that satisfies the general specifications described in this manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
•When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range. Undertightening can cause the GOT to drop, short circuit or malfunction, and deteriorate the waterproof effect and oilproof effect.
•Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or the GOT, and deteriorate the
waterproof effect and oilproof effect due to distortion of the protective cover for oil, GOT or panel.
•When using the GOT in the environment of oil or chemicals, use the protective cover for oil. Failure to do so may cause failure or malfunction due to the oil or chemical entering into the GOT.
DANGER WIRING PRECAUTIONS
•Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.
•Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.
•Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product. Not doing so can cause a fire or failure.
•Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.
•Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT. Not doing so can cause a fire, failure or malfunction.
CAUTION WIRING PRECAUTIONS
•Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit
DANGER TEST OPERATION PRECAUTIONS |
|
• Before performing the test operations of the user creation monitor |
|
screen (such as turning ON or OFF bit device, changing the word |
|
device current value, changing the settings or current values of |
3 |
Mitsubishi Electric Automation, Inc.
GT105_ QUICK START MANUAL
the timer or counter), read through the manual carefully and make yourself familiar with the operation method. During test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident..
DANGER STARTUP/MAINTENANCE PRECAUTIONS
•When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction.
•Connect the battery correctly. Do not discharge, disassemble, heat, short, solder or throw the battery into the fire. Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.
•Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not switching the power off in all phases can cause a unit failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
CAUTION STARTUP/MAINTENANCE PRECAUTIONS
•Do not drop or apply any impact to the battery. If any impact has been applied, discard the battery and never use it. The battery may be damaged by the drop or impact.
•Before touching the unit, always touch grounded metal, etc. to discharge static electricity from human body, etc. Not doing so can cause the unit to fail malfunction.
•Replace battery with GT11-50BAT by Mitsubishi electric Co. only. Use of another battery may present a risk of fire or explosion.
•Dispose of used battery promptly. Keep away from children. Do not disassemble and do not dispose of in fire..
CAUTION DISPOSAL PRECAUTIONS
•When disposing of the product, handle it as industrial waste.
•When disposing of batteries, separate them from other wastes according to the local regulations.
CAUTION TOUCH PANEL PRECAUTIONS
•For the analog-resistive film type touch panels, normally the adjustment is not required. However, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, execute the touch panel calibration.
•When any difference between a touched position and the object position occurs, other object may be activated. This may cause an unexpected operation due to incorrect output or malfunction.
CAUTION TRANSPORTATION PRECAUTIONS
•When transporting lithium batteries, make sure to treat them based on the transport regulations. (Refer to User’s Manual for details of the regurated models.)
•Before transporting the GOT, turn the GOT power on and check that the battery voltage status is normal on the Time setting & display screen (utilities screen). In addition, confirm that the adequate battery life remains on the rating plate. Transporting the GOT with the low battery voltage or the battery the reached battery life may unstabilize the backup data unstable during transportation.
•Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual, as they are precision devices. Failure to do so may cause the unit to fail.
•Check if the unit operates correctly after transportation.
4
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards. Compliance to EMC directive for the entire mechanical module should be checked by the user/manufacturer. For more details please contact the local Mitsubishi Electric sales site.
•This product is designed for use in industrial applications.
•Authorized Representative in the European Community: Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (to the identified standards) and design analysis (forming a technical construction file) to the European Directive for Electromagnetic Compatibility (2004/108/EC) when used as directed by the appropriate documentation. Type :Programmable Controller (Open Type Equipment)
Standard |
|
Remark |
|
|
EMI |
Compliance with all relevant aspects of the |
|
EN61131-2 : 2007 |
standard. (Radiated Emissions) |
||
|
|||
Programmable controllers- |
|
Compliance with all relevant aspects of the |
|
Equipment, requirement |
EMS |
standard. (ESD, RF electromagnetic field, |
|
and tests |
EFTB, Surge, RF conducted disturbances |
||
|
|||
|
|
and Power frequency magnetic field) |
Notes for compliance to EMC regulation
Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise. Therefore, when installing any communication cables care should always be taken with the routing and location of those cables. The GOT units identified on the previous chapter are compliant with the EMC requirement when the following communication cables are used.
GOT Unit |
Existing Cables |
User Made Cables |
|
|||||||||||||||||
GT1055-QSBD |
|
GT01-C30R4- |
Those cables need to be independently tested |
|||||||||||||||||
|
by the user to demonstrate EMC compatibility |
|||||||||||||||||||
and |
|
8P modified as |
||||||||||||||||||
|
when they are used with Mitsubishi GOT unit |
|||||||||||||||||||
GT1050-QBBD |
|
shown in EX.1 |
||||||||||||||||||
|
and FX3U Programmable Controllers. |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
||||||||||||
Ex.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
F = Ferrite core |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ex. NEC TOKIN - ESD-R-17S or similar |
|
GT01-C30R4-8P |
|
|||||||||||||||||
|
|
|
|
|
|
|
250mm |
|
|
|
|
|
|
|
|
100mm |
|
|||
|
|
|
|
|
|
(9.84inch) |
|
|
|
|
|
|
|
|
(3.93inch) |
|
||||
Programmable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GOT units |
||
|
|
|
|
|
|
F F |
|
|
|
F |
|
|
|
|||||||
controller |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
140mm |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
Comes equipped |
|
||||||||||||||
|
|
|
|
|
(5.51inch) |
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Added by user |
|
General notes on Power supply
The GT1055-QSBD and GT1050-QBBD unit requires an additional ferrite filter to be attached to the 24V DC power supply cables. The filter should be attached in a similar manner as shown in the figure opposite, i.e. the power cables are wrapped around the filter. However, as with all EMC situations the more correctly applied precautions the better the systems Electro-magnetic Compatibility. The ferrite recommended is a TDK ZCAT3035-1330 or similar. The ferrite should be placed as near to the 24VDC terminals of the GT1055-QSBD and GT1050-QBBD as possible (which should be within 75mm of the GOT terminal).
Up to 75mm (2.95inch)
Mitsubishi Electric Automation, Inc.
Product Name Model Name |
Specifications |
|
|
GT1055-QSBD |
GOT main unit |
GOT |
GT1050-QBBD |
(The maintenance supplies below are packed |
|
with the product.) |
|
|
|
Item |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Quantity |
|
|||||||||
Panel Mounting Bracket (with M4 X 20 screws) |
|
4 |
|
|||||||||||||||||||||||||||||
Panel Mounting Packing |
|
|
|
|
1 |
|
||||||||||||||||||||||||||
GT10 General Description Manual |
|
|
|
1 |
|
|||||||||||||||||||||||||||
2. SPECIFICATIONS |
|
|
|
|
|
|
||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2.1 MODEL NAME EXPLANATION |
|
|
|
|
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GT10 5 0 - |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power type |
|
D:24VDC |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Panel color type |
|
B:Black |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Display device type |
|
S:STN color |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B:STN monochrome(blue/white) |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Resolution |
|
Q:320 × 240(QVGA) |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Display color type |
|
5:256 colors supported |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Screen size type |
|
0:Monochrome(black/white) |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5:5.7" |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GOT1000 series |
|
GT10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
2.2 GENERAL SPECIFICATIONS |
|
|
|
|
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Item |
|
|
|
|
|
|
|
|
|
|
Specifications |
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
Display |
0 to 50°C |
|
|
|
|
|
|
|
|||||||||||||||
Operating |
|
Section |
|
|
|
|
|
|
|
|||||||||||||||||||||||
|
Other |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
Ambient |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
Than |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
Temp. |
|
0 to 55°C (When mounted horizontally), 0 to 50°C (When mounted vertically) |
||||||||||||||||||||||||||||||
|
Display |
|||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
Section |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Storage Ambient |
-20 to 60°C |
|
|
|
|
|
|
|
||||||||||||||||||||||||
Temperature |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Operating/Storage |
10 to 90% RH, non-condensing |
|
|
|
|
|||||||||||||||||||||||||||
ambient humidity |
(The wet bulb temperature is 39°C or less.) |
|
|
|
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequency |
Acceleration |
|
Half- |
Sweep |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
amplitude |
Count |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Conforms |
Under |
5 to 9Hz |
- |
|
3.5mm |
|
|||||||
Vibration |
|
|
|
|
|
|
|
|
|
|
to JIS |
intermittent |
|
|
|
|
|
10 times |
||||||||||||||
|
|
|
|
|
|
|
|
|
|
9 to 150Hz |
9.8m/s² |
|
- |
|||||||||||||||||||
Resistance |
|
|
|
|
|
|
|
|
|
|
B3502 and |
vibration |
|
each in X, |
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IEC61131-2 |
Under |
5 to 9Hz |
- |
|
1.75mm |
Y and Z |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
continuous |
|
|
|
|
|
directions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 to 150Hz |
4.9m/s² |
|
- |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
vibration |
|
|
|
|
|
|
Shock Resistance |
Conforms to JIS B3502, IEC 61131-2 (147 m/s², 11 ms, Sine half-wave pulse, |
|||||||||||||||||||||||||||||||
3 times each in the X, Y, and Z directions.) |
|
|
|
|||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
Operating |
|
|
|
|
|
|
|
|
|
|
Must be free of lamp black, corrosive gas, flammable gas, or excessive amount |
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
of electro conductive dust particles and must be no direct sunlight. (Same as |
||||||||||||||||||||||
Atmosphere |
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
for saving) |
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Operating Altitude *1 |
2000m (6562 ft.) max. |
|
|
|
|
|
|
|||||||||||||||||||||||||
Installation Location |
Inside control panel |
|
|
|
|
|
|
|||||||||||||||||||||||||
Overvoltage |
|
|
|
|
|
|
|
|
|
|
II or less |
|
|
|
|
|
|
|
||||||||||||||
Category *2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Pollution Degree *3 |
2 or less |
|
|
|
|
|
|
|
||||||||||||||||||||||||
Cooling Method |
Self-cooling |
|
|
|
|
|
|
|
1.Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction. When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press, and the sheet may be peeled off.
2.This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
3.*his index indicates the degree to which conductive material is generated in the environment where the equipment is used. In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.
|
|
GT105_ QUICK START MANUAL |
|
||
2.3 PERFORMANCE SPECIFICATIONS |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
Item |
|
GT1055-QSBD |
GT1050-QBBD |
|
|
|
Type |
STN color liquid crystal |
|
STN monochrome (white/blue) |
|
|
|
liquid crystal |
|
||
|
|
|
|
|
|
|
Screen Size |
5.7" |
|
|
|
*1 |
Resolution |
320 x 240 dots |
|
|
|
Display Size (WxH) |
115 x 86 (4.53 x 3.39) mm (inch) (Horizontal format) |
|
|||
Section |
|
||||
|
font: 53 characters x 20 lines (Horizontal Format) |
|
|||
|
Display Character |
16-dot standard font: 20 characters x 15 lines, 12-dot standard |
|
||
|
|
|
|
|
|
Display |
Display Color |
256 colors |
|
Monochrome (white/blue), 16 |
|
|
|
|
|||
|
|
scales |
|
||
|
|
|
|
|
|
|
Contrast Adjust. |
16-level adjustment |
|
|
|
|
Intensity of LCD Only |
380 [cd/m²] |
|
260 [cd/m²] |
|
|
Life |
Approx. 50,000h. (Time for display intensity to become 1/5 at |
|
||
|
operating ambient temperature of 25°C) |
|
|||
|
|
|
|||
|
|
Cold cathode fluorescent tube (irreplaceable by a user) |
|
||
|
Type |
backlight shutoff detection function is included. Backlight off/ |
|
||
|
|
screen saving time can be set. |
|
|
|
Backlight |
|
Approx. 75,000h or longer |
|
Approx. 54,000h or longer |
|
|
ambient temperature of 25°C) |
|
ambient temperature of 25°C) |
|
|
|
Life |
(Time for display intensity |
|
(Time for display intensity |
|
|
reaches 50% at the operating |
|
reaches 50% at the operating |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Green light : Power is supplied |
|
|
|
LED (POWER LED) |
Orange light : Screen saving |
|
|
||
Green / Orange flashing : Blown backlight bulb |
|
||||
|
|
|
|||
|
|
POWER LED is not lit : Power is not supplied |
|
||
|
No. of touch keys |
Maximum 50 keys/screen (Matrix resistive film touch panel) |
|
||
Panel |
Key size |
Minimum 16 x 16 dots (per key) |
|
|
|
Simultaneous |
|
|
|
|
|
Touch |
pressing of two (or |
Enable |
|
|
|
more) areas (2-point |
|
|
|||
|
|
|
|
|
|
|
press) |
|
|
|
|
|
Life |
1 million times or more (operating force 0.98N max.) |
|
||
|
|
|
|
|
|
Item |
|
GT1055-QSBD |
GT1050-QBBD |
|
|
|
C Drive *3 |
Flash memory ROM (Internal), for storing project data |
|
||
|
(3M bytes or less) and OS |
|
|
||
Memory |
|
|
|
||
|
SRAM (Internal), for storing alarm history, recipe data and time |
|
|||
|
Life |
100,000 (Number of write times) |
|
|
|
|
D Drive |
action setting value |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
Battery |
Model |
GT11-50BAT lithium battery |
|
|
|
Type |
Magnesium maganese dioxide lithium primary battery |
|
|||
|
|
||||
|
Backup Target |
Clock data, alarm history and recipe data |
|
||
|
Life |
Approx. 5 years (Operating ambient temperature of 25°C) |
|
||
Buzzer Output (a buzzer |
|
|
|
|
|
that sounds when touch |
Single tone (LONG/ SHORT/ OFF adjustable) |
|
|||
keys are pressed) |
|
|
|
|
|
Environmental Protective |
Equivalent to IP67 (JEM1030) (front section) |
|
|||
Structure *4 |
|
||||
|
|
|
|
||
External Dimensions |
164 x 135 x 56 (6.46 x 5.32 x 2.21) |
|
|||
W x H x D mm (inch) |
(Excluding mounting fixtures) (Horizontal format) |
|
|||
|
|
Conforming to serial RS-422/485 standard, 1ch |
|
||
|
|
Transmission speed: 115,200/57,600/38,400/19,200/9,600/ |
|
||
|
|
4,800bps |
|
|
|
|
RS-422/485 |
Connector shape: D-sub 9-pin (Female) |
|
||
|
|
Application: PLC communication |
|
|
|
|
|
Terminating resistor *5: Open/110Ω/330Ω (Switched by |
|
||
Interface |
|
terminating resistor selector switch) (At factory shipment: 330Ω) |
|
||
|
00bps |
|
|
||
|
|
Conforming to serial RS-232 standard, 1ch |
|
||
|
|
Transmission speed: 115,200/57,600/38,400/19,200/9,600/4,8 |
|
||
-in |
RS-232 |
Connector shape: D-sub 9-pin (Male) |
|
||
Built |
|
Application: PLC communication, bar code reader connection, |
|
||
|
PC communication (Project data upload/download, OS |
|
|||
|
|
installation, transparent function) |
|
||
|
|
Conforming to serial USB (Full Speed 12Mbps), device, 1ch |
|
||
|
USB |
Connector shape: Mini-B |
|
|
|
|
Application: PC communication (Project data upload/download, |
|
|||
|
|
|
|||
|
|
OS installation, transparent function) |
|
||
|
GT10-50FMB |
For connecting GT10-50FMB memory board |
|
||
Panel Cutting Dimensions |
(W x H) 153 x 121 (6.03 x 4.77) mm (inch) (Horizontal format) |
|
|||
Weight |
0.7kg (Excluding mounting fixtures) |
|
|||
Compatible Software |
GT Designer2 Version 2.90U or later/GT Designer3 Version |
5 |
|||
Package |
1.01B or later |
|
|||
|
|
Mitsubishi Electric Automation, Inc.
GT105_ QUICK START MANUAL
1.Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements. Flickers may be observed depending on the display color. Please note that these dots appear due to its characteristic and are not caused by product defect.
•Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment. However, please note that these phenomena appear due to its characteristic and are not caused by product defect.
•There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.
•• A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.
•When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.
•Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature. Especially in the low temperature environment, the display response becomes slow due to the characteristics of
the STN liquid crystal. Please check the display response in advance for using this product.
•When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear. To prevent heat damage, the screen saver function is effective. F
2.Using the GOT Backlight OFF function can prolong the life of the backlight.
3.ROM in which new data can be written without deleting the written data.
4.Note that this does not guarantee all users’ operation environment. In addition, the product may not be used in environments under exposition of oil or chemicals for a long period of time, or in environments filled with oil-mist.
5.Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting GOT multidrop connection. Gradation inversion is a characteristic of liquid crystal displays. Please be forewarned that depending on the displayed color, the visualization may be difficult even within the described view angle. Using the GOT Backlight OFF function can prolong the life of the backlight. The touch panel is analog resistive film-type. If you touch the panel simultaneously in 2 points or more, the switch that is located around the center of the touched point, if any, may operate. Do not touch the panel in 2 points or more simultaneously. Do not press the GOT display section with a pointed material as a pen or driver. Doing so can result
in a damage or failure of the display section. For the analog-resistive film type touch panels, normally the adjustment is not required. However, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, execute the touch panel calibration. When any difference between a touched position and the object position occurs, other object may be activated. This may cause an unexpected operation due to incorrect output or malfunction. ROM in which new data can be written without deleting the written data. Set the terminating resistor
selector switch of the GOT in accordance with the connection type when adopting GOT multidrop connection. Compliant with IP67 when the USB environmental protection cover is attached. Not compliant when a USB cable is connected. Note that this does not guarantee all users’ operation
environment. The protection is not applied when the interface environment protection cover is removed. In addition, the product may not be used in environments under exposition of oil or chemicals for a long period of time, or in environments filled with oil-mist.
Appearance
White stripe patterns may appear on the surface of the resin molded part of the product. Please note that these phenomena appear due to the characteristics of the material used in the product and are not caused by product defect.
|
GT1055-QSBD |
GT1050-QBBD |
|
Input power supply |
24VDC (+10% -15%) |
|
|
voltage |
|
||
|
|
||
Fuse (built-in, not |
1.0A |
|
|
exchangeable) |
|
||
|
|
||
|
9.84W (410mA/24VDC) |
9.36W (390mA/24VDC) |
|
Power Consumption (At |
or less, |
or less, |
|
backlight off) |
(4.32W (180mA/24VDC) |
(4.32W (180mA/24VDC) |
|
|
or less) |
or less) |
|
Inrush current |
15A or less (26.4VDC) 2ms |
|
|
Permissible |
|
|
|
instantaneous power |
Within 5ms |
|
|
failure time *1 |
|
|
|
Noise immunity |
Noise voltage: 1000Vp-p, Noise width: 1µs (by noise |
||
simulator of 30 to 100Hz noise frequency) |
|||
|
|||
Dielectric withstand |
500VAC for 1 minute (across power supply terminals |
||
voltage |
and earth) |
|
|
Insulation resistance |
10MΩ or larger by insulation resistance tester (across |
||
power supply terminals and earth) |
|||
|
|||
Grounding |
Class D grounding (100Ω or less). To be connected |
||
to the panel when grounding is not possible |
|||
|
*1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure. The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored.
6
FRONT PANEL
1) 2)
3)
No. |
Name |
Description |
|
|
|
Displays the utility screen and the user creation screen. |
|
(1) |
Display section |
GT1055-QSBD : 320 240 dots, STN color liquid crystal |
|
GT1050-QBBD : 320 240 dots, STN monochrome (white/ |
|||
|
|
||
|
|
blue) liquid crystal |
|
(2) |
Touch panel |
For operating the touch switches in the utility screen and the |
|
user creation screen |
|||
|
|
||
|
|
Green light: Power is supplied |
|
(3) |
POWER LED |
Orange light: Screen saving (At backlight off) |
|
Green / Orange flashing: Blown backlight bulb |
|||
|
|
||
|
|
POWER LED is not lit: Power is not supplied |
BACK PANEL
|
1) |
2) |
7) |
|
|
|
|
|
|
|
|
|
|
Battery cover opened |
|
|
|
|
|
|
|
(Hardware version A to B) |
|
|
|
|
|
|
|
10) |
|
|
|
|
|
|
|
(Hardware version |
|
|
|
|
|
|
|
C or later) |
|
|
|
|
|
|
|
Power supply |
|
|
|
|
|
|
|
terminal layout |
|
|
|
5) 6) |
9) |
3) 4) |
11)12) |
||
|
|
|
|
|
|
13) |
|
|
|
8) |
|
|
8) |
|
|
No. |
Name |
|
Description |
|
|
||
|
|
|
|
For communicating with controller (PLC, |
|||
(1) |
PLC connection |
|
microcomputer board, bar code reader, etc) or |
||||
interface (RS-232) |
personal computer (OS installation, project data |
||||||
|
|||||||
|
|
|
|
download, transparent) (D-sub 9-pin male) |
|||
(2) |
PLC connection |
|
For communicating with controller (PLC, |
||||
interface (RS-422) |
microcomputer board, etc) (D-sub 9-pin female) |
||||||
|
|||||||
(3) |
USB interface |
|
For PC connection (OS installation, project data |
||||
|
download, transparent) (Mini-B) |
||||||
|
|
|
|
||||
(4) |
USB cover |
|
Open or close when using the USB interface |
||||
(5) |
Power terminal |
|
Power terminal and FG terminal (for power supply |
||||
|
(24VDC) to GOT and grounding) |
||||||
|
|
|
|
||||
(6) |
Power terminal |
|
Open or close when connecting a power terminal. |
||||
cover |
|
|
(Color: transparent) (Hardware version B or later) |
||||
|
|
|
|||||
(7) |
Rating plate |
|
- |
|
|
||
(nameplate) |
|
|
|
||||
|
|
|
|
|
|||
(8) |
Hole for unit |
|
Hole for the inserting installation fittings (accessory) |
||||
|
during the GOT installation to the panel (4 holes at top |
||||||
installation fitting |
|
||||||
|
|
and bottom) |
|
|
|||
|
|
|
|
|
|
||
(9) |
Battery cover |
|
Open or close when replacing the battery. |
Mitsubishi Electric Automation, Inc.
GT105_ QUICK START MANUAL
GT11-50BAT battery for storing clock data, alarm (10) Battery history, recipe data and time action setting value (The
project data is stored in the built-in flash memory.)
(11) |
Memory board |
Remove when using the memory board. |
|
cover |
|||
|
|
||
(12) |
Memory board |
Interface for mounting the memory board to the GOT. |
|
interface |
|||
|
|
||
|
Terminating |
Terminating resistor selector of RS422/485 |
|
(13) |
resistor selector |
||
(330Ω /OPEN/110Ω) (At factory shipment: 330Ω) |
|||
|
switch (TERM.) |
||
|
|
|
164(6.46") |
|
22 |
120(4.73") |
|
(0.87") |
23(0.91") |
|
|
|
|
|
10 |
(0.4") |
#4-40UNC
(Inch screw type)
|
135(5.32") |
120 |
M2.6 |
|
(4.73") |
||
|
|
|
(Metric screw type) |
|
|
10 |
(0.4") |
22 |
120(4.73") |
Panel thickness: 5mm(0.2") or less |
|
|
|
(0.87")
53(2.09") |
6(0.24") |
47(1.86") |
56(2.21") |
|
152(5.99") |
|
|
Memory board connected
62(2.44") |
Unit: mm(inch) |
|
Example nameplate (manufacture's serial number 1010001)
GRAPHIC OPERATION TERMINAL |
|
MODEL |
GT1055-QSBD |
IN 20.4 26.4VDC POWER 2.2W MAX |
|
S/N |
1010001 AA |
MITSUBISHI ELECTRIC CORPORATION |
|
MADE IN JAPAN |
<Jan., 2010 or later> |
|
*Actual product nameplate differs |
|||
7-digit |
|
|
|
from the example shown above. |
|
|
|
|
|
|
|
0 |
1 |
10 |
0 |
0 |
1 |
Control number
Month (example: Jan.). 1 to 9: Jan. to Sep.,
X: Oct., Y: Nov., Z: Dec.
Year (example: 2010)
Last two digit of year
<Dec., 2009 or before> 6-digit
9 X 0 0 0 1
Control number
Month (example: Oct.). 1 to 9: Jan. to Sep.,
X: Oct., Y: Nov., Z: Dec.
Year (example: 2009) Last digit of year
How to confirm production year and month
The production date of the optional replacement battery can be confirmed by the lot No. marked on the nameplate (label) affixed on the battery.
Nameplate
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Connector |
|||||
|
Model name |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
GT11-50BAT |
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
LOT. |
|
|
LOT.101 |
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
<Jan., 2010 or later> |
|
|
<Dec., 2009 or before> |
||||||||||||||||||
|
|
||||||||||||||||||||
|
3-digit |
|
|
|
|
|
2-digit |
||||||||||||||
|
|
1 |
|
|
0 |
1 |
|
8 |
|
X |
|||||||||||
|
|
|
|
|
|
|
|
Month |
|
|
|
|
|
|
|
|
|
|
|
Month |
|
|
|
|
|
|
|
|
|
(example:Jan.) |
|
|
|
|
|
|
|
|
|
(example: Oct.) |
|||
|
|
|
|
|
|
|
|
1 (Jan.) to 9 (Sep.), |
|
|
|
|
|
|
|
|
|
1 (Jan.) to 9 (Sep.), |
|||
|
|
|
|
|
|
|
|
X (Oct.), Y (Nov.), Z (Dec.) |
|
|
|
|
|
X (Oct.), Y (Nov.), Z (Dec. |
|||||||
|
|
|
Year (example: 2010) |
|
|
|
|
|
|
|
|
|
Year (example: 2008) |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
Last two digit of year |
|
|
|
|
|
|
|
|
|
Last digit of year |
Mount the GOT onto the control panel while considering the following control panel inside dimensions.
Horizontal format.
30 152 (5.99") (1.19")
120 (4.73") |
140 (5.52") |
Unit:mm(inch)
Vertical format.
140 (5.52")
120 (4.73")
152 (5.99")
30 (1.19") |
Unit:mm(inch) |
Applicable cable
Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.
7
Mitsubishi Electric Automation, Inc.
GT105_ QUICK START MANUAL
Cut holes in the following dimensions on the panel. A space of top and bottom is required to allow for the attachment of mounting fixtures.
|
• Horizontal format |
|
• Vertical format |
|
|
|||
|
|
A |
C |
C |
|
B |
|
C |
|
|
|
|
|
|
|
||
|
|
|
B |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A |
|
|
|
C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Unit: mm(inch) |
|
|
|
Unit: mm(inch) |
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
GOT |
A |
|
B |
C |
|
Panel Thickness |
||
|
|
mm (inch) |
||||||
|
|
|
|
|
|
|
|
|
GT105 |
153 (6.03") |
|
121 (4.77") |
10 (0.39") or |
|
Within 2 (0.07") |
||
(+2 (0.07"), 0 (0)) |
(+2 (0.07"), 0 (0)) |
more |
|
to 5 (0.19") |
||||
|
|
|
When mounting the GOT, the following clearances must be maintained from other structures and devices.
Horizontal position
Installation Environment |
A |
B |
C |
D |
E |
|
|
|
|
|
|
In the presence of radiated- |
50 mm |
80 mm |
50 mm |
50 mm |
100 mm |
noise or heat-generating |
(1.97") |
(3.14") or |
(1.97") or |
(1.97") |
(3.93") or |
equipment nearby |
or more |
more *1 |
more*2 |
or more |
more |
In the absence of radiated- |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
noise or heat-generating |
(0.79") or |
(0.79") or |
(0.79") or |
(0.79") or |
(0.79") or |
equipment nearby |
more |
more |
more |
more |
more |
Other device or control panel
|
B |
|
C |
D |
E |
|
A |
|
Vertical position
Installation Environment |
A |
B |
C |
D |
E |
|
|
|
|
|
|
In the presence of radiated- |
50 mm |
50 mm |
80 mm |
50 mm |
100 mm |
noise or heat-generating |
(1.97") |
(1.97") |
(3.14") or |
(1.97") |
(3.93") or |
equipment nearby |
or more |
or more |
more *1 |
or more |
more |
In the absence of radiated- |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
noise or heat-generating |
(0.79") or |
(0.79") or |
(0.79") or |
(0.79") or |
(0.79") or |
equipment nearby |
more |
more |
more |
more |
more |
8
Other device or control panel
|
B |
|
C |
D |
E |
|
A |
|
When mounting the main unit to a control panel or similar fixture, set the GOT display section as shown below.
Horizontal installation
When the temperature inside the control panel is 40° to 55°, the mounting angle should be in the range from 60 to 105 degrees.
Vertical installation
When the temperature inside the control panel is 40° to 50°, the mounting angle should be in the range from 60 to 105 degrees.
|
GOT |
|
|
back |
|
GOT |
panel |
|
105° |
||
display |
||
section |
60° |
|
|
||
Control |
|
|
panel, etc. |
|
The GOT will have a longer lifetime if used within the mounting angles shown above. Ideally, the temperature inside the control panel should not exceed 0 to 40°C
The GOT is designed to be embedded into a panel. Mount the GOT by following the procedure below.
Cautions on the installation panel
Make sure that the panel surface is free from warpage, flaws and irregularities. Warpage, flaws and irregularities may disable the waterproof effect. Select proper panel thickness under consideration of the panel strength. (For example, the panel strength may be insufficient depending on the panel material and dimensions even
if the panel thickness is acceptable. Insufficient panel strength may cause warpage depending on the installation positions of the GOT and other equipment.) Installing the packing Install packing to the packing installation groove on the back panel of the GOT. While referring to
the cross sectional view of the packing shown right, push the thinner side into the packing groove. (Drawing below is the example of lateral format.)
Mitsubishi Electric Automation, Inc.