DRG-LV |
|
DESCRIPTION |
The DRG has a “F” connector for attaching an antenna. The |
STEP 1 Open receiver case. To open case, |
|||||||
|
The DRG-LV |
is a digital receiver designed for use with |
receiver is supplied with a 9-inch local antenna, a three foot |
squeeze sides of case and rotate upward. |
|||||||
DRG-2LV |
|
automatic gate operators or systems where a remote antenna |
75 ohm coaxial cable, and a bulkhead |
connector for |
|
|
|
||||
|
mounting the antenna outside the gate operator enclosure. |
|
|
|
|||||||
|
is needed. The DRG-2LV will operate two gates, one gate and |
|
|
|
|||||||
|
|
|
an obstacle sensor or channel one can open the gate and |
|
|
|
|
|
|
|
|
|
|
|
channel two can close the gate. |
RECEIVER |
|
|
|
|
|
|
|
|
|
|
All of the Delta-3 transmitters, including the two and |
|
|
|
|
|
|
||
|
|
|
|
|
|
3-FOOT |
|
|
|
||
DIGITAL |
|
four-channel transmitters, are compatible with the the DRG. |
|
|
|
CABLE |
|
|
|
||
|
|
|
|
|
|
|
|
||||
|
The Delta-3 radio format provides 256 different digital codes. |
|
|
|
|
|
|
|
|||
GATE |
|
|
The codes are set using the 8-position coding switches in the |
|
|
|
CASE SCREWS |
|
|
|
|
RECEIVER |
|
units. In order to avoid the possibility of duplicating codes in |
|
|
|
|
|
|
|
||
|
adjacent systems, factory set codes should not be used. |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
||
Installation Instructions |
The receivers can operate from 10.2-16 VDC or 12-16 VAC |
|
|
|
|
|
|
|
|||
and are normally powered from the gate operator. The relay |
|
|
|
MOUNTING |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|||
|
|
|
contact(s) are rated at 5 amps @ 30 volts AC/DC NEC Class |
|
|
|
HARDWARE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
2 circuit. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LOCAL |
|
NUT |
|
|
|
|
|
|
|
|
|
ANTENNA |
BULKHEAD |
WASHER |
SQUEEZE BOTH SIDES AT TABS |
|
|
|
|
|
|
|
|
|
CONNECTOR |
AND TILT UPWARD |
|
|
|
(800) 421-1587 ∙ www.linearcorp.com |
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|||
STEP 2A |
DRG-LV code setting. To set a |
STEP 2B |
DRG-2LV code setting. Select any |
STEP 3 |
Transmitter code setting. Locate |
STEP 4 Connect receiver relay output. |
|||||
code, select any valid combination of ON and |
valid combination of ON and OFF positions for |
the coding switch on the transmitter and set the |
Connect the appropriate channel wires (Ch. 1 - |
||||||||
OFF positions for the switch keys numbered 1- 8. |
each of the switch keys numbered 1 - 8. Use a |
eight keys identical to those on the desired |
two gray wires), (Ch. 2 - two yellow wires) to the |
||||||||
Use a paper clip to set the eight keys. |
different code combination than that used for |
channel of the receiver. Be sure they match |
appropriate activation terminals on the gate |
||||||||
|
|
|
channel one switch. |
exactly. I f |
u s i n g a t w o |
o r f o u r - c h a n n e l |
operator. |
|
|
||
SET CODE |
|
|
|
transmitter, refer to the coding instructions |
|
|
|
||||
|
|
|
included with the transmitter for proper system |
|
GATE OPERATOR |
||||||
SWITCH KEYS |
|
SET CHANNEL TWO |
coding. |
|
|
|
DRG |
|
MANUAL ACCESS |
||
|
|
|
CODE SWITCH KEYS |
|
|
|
|
Digital Gate Receiver |
|
REQUEST |
|
|
|
|
|
|
|
|
|
|
|||
CHANNEL ONE |
|
|
|
|
|
|
|
|
|
|
|
SWITCH KEYS |
|
CHANNEL TWO |
REMOVE BATTERY |
|
|
|
|
|
|||
|
|
|
ACCESS DOOR |
|
|
|
|
1 |
COMMON |
||
|
|
|
SWITCH KEYS |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
SWITCHES IN |
CHANNEL |
2 |
RELAY |
|
|
|
|
|
|
|
|
TRANSMITTER |
ONE |
|
|
|
|
|
|
|
|
|
|
GRAY |
|
|
||
|
|
|
|
|
|
|
|
|
3 12 V RADIO POWER |
||
|
|
|
|
|
|
|
|
|
|
||
THIS SWITCH |
|
THIS SWITCH |
|
|
|
|
|
|
|
||
HAS 2, 3 & 6 ON |
|
|
|
|
|
|
OBSTACLE INPUT |
||||
|
HAS 2, 4 & 6 ON |
|
CODING |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|||
DO NOT USE: |
|
|
|
|
SWITCH |
|
|
YELLOW |
1 |
COMMON |
|
|
|
|
|
|
|
THIS SWITCH |
|||||
|
DO NOT USE: |
|
|
|
CHANNEL |
|
|||||
ALL ON; ALL OFF; |
|
|
|
|
TWO |
|
|
||||
|
ALL ON; ALL OFF; |
|
|
|
HAS 2, 3 & 6 ON |
2 |
OBSTACLE |
||||
ALT ON/OFF, OR OFF/ON |
|
|
|
|
|
||||||
|
ALT ON/OFF, OR OFF/ON |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
||
STEP 5 |
C o n n e c t r e c e i v e r t o p o w e r . |
STEP 6 |
Mounting the receiver. U s e t h e |
STEP 7 |
Connect antenna. C o n n e c t t h e |
LINEAR LIMITED WARRANTY |
|||||
Connect the red power input wire to the 12V radio |
screws provided to mount the receiver within the |
coaxial cable to the “F” connector on the receiver. |
This product is warranted to the consumer against defects in material and workmanship |
||||||||
for one year from the date of purchase. This warranty applies to first retail buyers of |
|||||||||||
power and the black wire to the common terminal |
operator housing. This provides protection from |
Drill a 3/8" hole on the top of the operator housing |
new devices. Warrantor will repair, or at its option, replace, any device it finds that |
||||||||
requires service under this warranty, and will return the repaired or replaced device to |
|||||||||||
on the gate operator. Alternately connect wires to |
the elements. Secure case with case screws. |
for the bulkhead connector. Insert the connector |
the consumer at the warrantor’s cost. For warranty service and shipping instructions |
||||||||
a 12-16 VAC transformer. |
|
|
|
and secure it with the nut and lock washer. |
contact warrantor at the address shown below. Devices must be sent to warrantor for |
||||||
|
|
|
service at owner’s expense. The remedies provided by this warranty are exclusive. |
||||||||
|
|
|
|
|
Connect the cable and antenna to the operator. |
Implied warranties under state law are to the one year period of this written warranty. |
|||||
|
|
|
|
|
|
|
|
|
Some states do not allow limitations on how long an implied warranty lasts, so the above |
||
|
|
|
|
|
|
|
|
|
limitation may not apply to you. In order to be protected by this warranty, save your |
||
|
GATE OPERATOR |
|
|
|
|
|
|
proof of purchase and send copy with equipment should repair be required. This |
|||
|
|
|
|
|
|
|
warranty gives you specific legal rights, and you may also have other rights which vary |
||||
|
|
|
|
|
|
|
|
|
from state to state. |
|
|
|
|
MANUAL |
|
MOUNT RECEIVER |
|
|
SLIDE WEATHER |
All products returned for warranty service require a Return Product Authorization Number |
|||
|
|
|
|
|
(RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other |
||||||
|
|
ACCESS REQUEST |
|
|
|
RESISTANT CAP |
|||||
|
|
|
INSIDE GATE |
|
|
important details. |
|
|
|||
DRG |
|
|
|
CONNECT COAXIAL |
OVER CONNECTION |
|
|
||||
|
|
|
IMPORTANT !!! |
|
|||||||
|
|
|
HOUSING |
|
|
|
|||||
Digital Gate Receiver |
|
|
|
CABLE TO "F" |
|
|
|
|
|||
|
|
OBSTACLE |
|
|
|
|
Linear radio controls provide a reliable communications link and fill an important need |
||||
|
|
|
|
CONNECTOR |
|
|
|
||||
|
BLACK |
|
|
|
|
|
INSERT BULKHEAD |
in portable wireless signaling. However, there are some limitations which must be |
|||
|
|
|
|
|
|
observed. |
|
|
|||
|
|
|
|
|
|
|
|
|
|
||
|
1 |
COMMON |
|
|
|
|
CONNECTOR THROUGH |
For U.S. installations only: The radios are required to comply with FCC Rules and |
|||
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
OPERATOR HOUSING |
Regulations as Part 15 devices. As such, they have limited transmitter power and |
|||
|
2 |
RELAY |
|
|
|
|
|
|
therefore limited range. |
|
|
|
RED |
|
|
|
|
|
|
|
A receiver cannot respond to more than one transmitted signal at a time and may be |
||
|
12 V RADIO POWER |
|
|
|
|
|
|
blocked by radio signals that occur on or near their operating frequencies, regardless of |
|||
|
3 |
|
SECURE CASE |
|
|
SECURE CONNECTOR |
code settings. |
|
|
||
|
|
|
|
|
|
|
|
||||
|
|
|
|
CLOSED WITH TWO |
|
|
TO HOUSING USING |
Changes or modifications to the device may void FCC compliance. |
|||
|
|
|
|
SCREWS AT BOTTOM |
|
|
WASHER AND NUT |
Infrequently used radio links should be tested regularly to protect against undetected |
|||
|
|
|
|
|
|
|
|
interference or fault. |
|
|
|
|
INPUT VOLTAGE REQUIREMENT |
|
OF CASE |
|
|
|
|
|
|
||
|
|
|
|
CONNECT CABLE TO |
A general knowledge of radio and its vagaries should be gained prior to acting as a |
||||||
|
10.2-16 VOLT DC or 12-16 VAC |
|
|
|
|
||||||
|
|
|
|
|
BULKHEAD CONNECTOR |
wholesale distributor or dealer, and these facts should be communicated to the ultimate |
|||||
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
users. |
|
|
|
|
|
|
|
|
|
|
|
Copyright © 1999 Linear Corporation |
|
216267 B |