DRG-LV

 

DESCRIPTION

The DRG has a “F” connector for attaching an antenna. The

STEP 1 Open receiver case. To open case,

 

The DRG-LV

is a digital receiver designed for use with

receiver is supplied with a 9-inch local antenna, a three foot

squeeze sides of case and rotate upward.

DRG-2LV

 

automatic gate operators or systems where a remote antenna

75 ohm coaxial cable, and a bulkhead

connector for

 

 

 

 

mounting the antenna outside the gate operator enclosure.

 

 

 

 

is needed. The DRG-2LV will operate two gates, one gate and

 

 

 

 

 

 

an obstacle sensor or channel one can open the gate and

 

 

 

 

 

 

 

 

 

 

channel two can close the gate.

RECEIVER

 

 

 

 

 

 

 

 

 

All of the Delta-3 transmitters, including the two and

 

 

 

 

 

 

 

 

 

 

 

 

3-FOOT

 

 

 

DIGITAL

 

four-channel transmitters, are compatible with the the DRG.

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

 

 

 

The Delta-3 radio format provides 256 different digital codes.

 

 

 

 

 

 

 

GATE

 

 

The codes are set using the 8-position coding switches in the

 

 

 

CASE SCREWS

 

 

 

RECEIVER

 

units. In order to avoid the possibility of duplicating codes in

 

 

 

 

 

 

 

 

adjacent systems, factory set codes should not be used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Instructions

The receivers can operate from 10.2-16 VDC or 12-16 VAC

 

 

 

 

 

 

 

and are normally powered from the gate operator. The relay

 

 

 

MOUNTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

contact(s) are rated at 5 amps @ 30 volts AC/DC NEC Class

 

 

 

HARDWARE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 circuit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOCAL

 

NUT

 

 

 

 

 

 

 

 

 

ANTENNA

BULKHEAD

WASHER

SQUEEZE BOTH SIDES AT TABS

 

 

 

 

 

 

 

 

CONNECTOR

AND TILT UPWARD

 

 

(800) 421-1587 www.linearcorp.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 2A

DRG-LV code setting. To set a

STEP 2B

DRG-2LV code setting. Select any

STEP 3

Transmitter code setting. Locate

STEP 4 Connect receiver relay output.

code, select any valid combination of ON and

valid combination of ON and OFF positions for

the coding switch on the transmitter and set the

Connect the appropriate channel wires (Ch. 1 -

OFF positions for the switch keys numbered 1- 8.

each of the switch keys numbered 1 - 8. Use a

eight keys identical to those on the desired

two gray wires), (Ch. 2 - two yellow wires) to the

Use a paper clip to set the eight keys.

different code combination than that used for

channel of the receiver. Be sure they match

appropriate activation terminals on the gate

 

 

 

channel one switch.

exactly. I f

u s i n g a t w o

o r f o u r - c h a n n e l

operator.

 

 

SET CODE

 

 

 

transmitter, refer to the coding instructions

 

 

 

 

 

 

included with the transmitter for proper system

 

GATE OPERATOR

SWITCH KEYS

 

SET CHANNEL TWO

coding.

 

 

 

DRG

 

MANUAL ACCESS

 

 

 

CODE SWITCH KEYS

 

 

 

 

Digital Gate Receiver

 

REQUEST

 

 

 

 

 

 

 

 

 

CHANNEL ONE

 

 

 

 

 

 

 

 

 

 

SWITCH KEYS

 

CHANNEL TWO

REMOVE BATTERY

 

 

 

 

 

 

 

 

ACCESS DOOR

 

 

 

 

1

COMMON

 

 

 

SWITCH KEYS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCHES IN

CHANNEL

2

RELAY

 

 

 

 

 

 

 

TRANSMITTER

ONE

 

 

 

 

 

 

 

 

 

GRAY

 

 

 

 

 

 

 

 

 

 

 

3 12 V RADIO POWER

 

 

 

 

 

 

 

 

 

 

THIS SWITCH

 

THIS SWITCH

 

 

 

 

 

 

 

HAS 2, 3 & 6 ON

 

 

 

 

 

 

OBSTACLE INPUT

 

HAS 2, 4 & 6 ON

 

CODING

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT USE:

 

 

 

 

SWITCH

 

 

YELLOW

1

COMMON

 

 

 

 

 

 

THIS SWITCH

 

DO NOT USE:

 

 

 

CHANNEL

 

ALL ON; ALL OFF;

 

 

 

 

TWO

 

 

 

ALL ON; ALL OFF;

 

 

 

HAS 2, 3 & 6 ON

2

OBSTACLE

ALT ON/OFF, OR OFF/ON

 

 

 

 

 

 

ALT ON/OFF, OR OFF/ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 5

C o n n e c t r e c e i v e r t o p o w e r .

STEP 6

Mounting the receiver. U s e t h e

STEP 7

Connect antenna. C o n n e c t t h e

LINEAR LIMITED WARRANTY

Connect the red power input wire to the 12V radio

screws provided to mount the receiver within the

coaxial cable to the “F” connector on the receiver.

This product is warranted to the consumer against defects in material and workmanship

for one year from the date of purchase. This warranty applies to first retail buyers of

power and the black wire to the common terminal

operator housing. This provides protection from

Drill a 3/8" hole on the top of the operator housing

new devices. Warrantor will repair, or at its option, replace, any device it finds that

requires service under this warranty, and will return the repaired or replaced device to

on the gate operator. Alternately connect wires to

the elements. Secure case with case screws.

for the bulkhead connector. Insert the connector

the consumer at the warrantor’s cost. For warranty service and shipping instructions

a 12-16 VAC transformer.

 

 

 

and secure it with the nut and lock washer.

contact warrantor at the address shown below. Devices must be sent to warrantor for

 

 

 

service at owner’s expense. The remedies provided by this warranty are exclusive.

 

 

 

 

 

Connect the cable and antenna to the operator.

Implied warranties under state law are to the one year period of this written warranty.

 

 

 

 

 

 

 

 

 

Some states do not allow limitations on how long an implied warranty lasts, so the above

 

 

 

 

 

 

 

 

 

limitation may not apply to you. In order to be protected by this warranty, save your

 

GATE OPERATOR

 

 

 

 

 

 

proof of purchase and send copy with equipment should repair be required. This

 

 

 

 

 

 

 

warranty gives you specific legal rights, and you may also have other rights which vary

 

 

 

 

 

 

 

 

 

from state to state.

 

 

 

 

MANUAL

 

MOUNT RECEIVER

 

 

SLIDE WEATHER

All products returned for warranty service require a Return Product Authorization Number

 

 

 

 

 

(RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other

 

 

ACCESS REQUEST

 

 

 

RESISTANT CAP

 

 

 

INSIDE GATE

 

 

important details.

 

 

DRG

 

 

 

CONNECT COAXIAL

OVER CONNECTION

 

 

 

 

 

IMPORTANT !!!

 

 

 

 

HOUSING

 

 

 

Digital Gate Receiver

 

 

 

CABLE TO "F"

 

 

 

 

 

 

OBSTACLE

 

 

 

 

Linear radio controls provide a reliable communications link and fill an important need

 

 

 

 

CONNECTOR

 

 

 

 

BLACK

 

 

 

 

 

INSERT BULKHEAD

in portable wireless signaling. However, there are some limitations which must be

 

 

 

 

 

 

observed.

 

 

 

 

 

 

 

 

 

 

 

 

 

1

COMMON

 

 

 

 

CONNECTOR THROUGH

For U.S. installations only: The radios are required to comply with FCC Rules and

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATOR HOUSING

Regulations as Part 15 devices. As such, they have limited transmitter power and

 

2

RELAY

 

 

 

 

 

 

therefore limited range.

 

 

 

RED

 

 

 

 

 

 

 

A receiver cannot respond to more than one transmitted signal at a time and may be

 

12 V RADIO POWER

 

 

 

 

 

 

blocked by radio signals that occur on or near their operating frequencies, regardless of

 

3

 

SECURE CASE

 

 

SECURE CONNECTOR

code settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLOSED WITH TWO

 

 

TO HOUSING USING

Changes or modifications to the device may void FCC compliance.

 

 

 

 

SCREWS AT BOTTOM

 

 

WASHER AND NUT

Infrequently used radio links should be tested regularly to protect against undetected

 

 

 

 

 

 

 

 

interference or fault.

 

 

 

INPUT VOLTAGE REQUIREMENT

 

OF CASE

 

 

 

 

 

 

 

 

 

 

CONNECT CABLE TO

A general knowledge of radio and its vagaries should be gained prior to acting as a

 

10.2-16 VOLT DC or 12-16 VAC

 

 

 

 

 

 

 

 

 

BULKHEAD CONNECTOR

wholesale distributor or dealer, and these facts should be communicated to the ultimate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

users.

 

 

 

 

 

 

 

 

 

 

 

Copyright © 1999 Linear Corporation

 

216267 B

Loading...