Kyocera FS-3040P, FS-2020, FS-3540, FS-3040, FS-3140P Service Bulletin 2J0 0028 B363

...
0 (0)
Kyocera FS-3040P, FS-2020, FS-3540, FS-3040, FS-3140P Service Bulletin 2J0 0028 B363

Service Bulletin

(Page.1/2)

Ref. No. 2J0-0028 (B363)

<Date> November 14, 2011

Subject Measures against the Developer Bias Failure

FS-2000D, FS-3900DN, FS-4000DN, FS-2020D, FS-3920DN,

Model

FS-4020DN, FS-2025D, FS-3925DN, FS-4025DN, FS-3040MFP, FS-3140MFP, FDS-3040MFP+, FS-3140MFP+, FS-3540MFP, FS-3640MFP

Topic

A spacer was affixed to the developer bias terminal on the machine side in order to prevent the faint image caused by contact failure of the developer bias terminal with the developer unit.

Developer contact

 

 

 

 

 

No protrusion

 

 

 

0.5 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

Spacer affixed

 

 

No protrusion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.5 mm

 

CONTACT BIAS (302F902270)

SPACER CONTACT BIAS

13mm

0.5mm

6.5mm

KMC’s Classification

Entire Stock Rework

In-Field modification at next visit

 

In-Field modification by case

No modification necessary

 

 

Field Measure: No particular problem is expected.

 

Serial Nos. of the Affected Machines: Please refer to the next page.

KYOCERA MITA Europe B.V.

European Service & Development Center (ESDC)

Loading...