Service Bulletin
(Page.1/2)
Ref. No. 5H3-0003 (C279)
<Date> Oct. 19, 2012
|
|
Subject |
|
|
Change of the Feed Clutch (Permanent Measures against the |
||
|
|
|
|
Noise) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Model |
|
|
PF-310, PF-310+, PF-430 |
|
|
|
|
|
|
|
|||
<Affected machines> |
|
|
|||||
PF-310: |
FS-2000D, FS-2020D, FS-2025D, FS-3900DN, FS-3920DN, FS-4000DN, FS-4020DN, FS-3925DN, |
||||||
|
|
|
|
FS-4025DN, FS-3040MFP, FS-3140MFP, |
|
||
PF-310+: |
FS-3540MFP, FS-3640MFP, FS-3040MFP+, FS-3140MFP+ |
|
|||||
PF-430: |
FS-6950DN, FS-6970DN, FS-6975DN |
|
|||||
|
|
|
|
||||
|
KDC’s Classification |
Entire Stock Rework |
In-Field modification at next visit |
||||
|
|
|
|
|
|
In-Field modification by case |
No modification necessary |
Field Measure:
When replacing the clutches (old No.3 to new No.3) in the cassette attached to the polyester slider, there is no need to remove the polyester slider.
Serial Nos. of the Affected Machines: To be informed later
Topic
A polyester slider was added as the measure against noise as informed by the service bulletin SB-5H3-0002-B068 (issued on March 8, 2011). This time, the size of the clutch gears was changed and the polyester sliders were removed as the permanent measures and in order to improve the process efficiency. (As the size of the gear was changed, interference of the gear will be prevented, which made removal of the polyester sliders possible.)
In addition, the polyester slider and the leaflet were deleted from service parts.
Content of Changes
7.5 mm |
|
|
|
6.5 mm |
CLIP |
||||
CLIP |
|
|
|||||||
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
Removed polyester |
|
|
|
|
Polyester slider |
|
|
|
||
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
slider |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
KYOCERA Document Solutions Europe
Technical Customer Service Division (TCSD)