CMOS Laser Analog Sensor
IA Series
Instruction Manual
Read this manual before using the product in order to achieve maximum
performance.
Keep this manual in a safe place after reading it so that it can be used at
any time.
Symbols
The following symbols alert you to important messages. Be sure to read these
messages carefully.
It indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in
product damage as well as property damage.
It indicates cautions and limitations that must be followed
during operation.
Safety measures for the laser
Laser radiation emission indicator
The laser radiation emission indicator lights up after turning on the power and
while the laser beam is being emitted.
Laser emission stop input
The laser emission stops when an emission stop (purple line) signal is input (for
20 ms or longer). The emission stops while the signal is input. The laser beam is
emitted a maximum of 20 ms after the signal input is canceled. An analog output
of 0.2 V is delivered during laser emission stop.
Warming up
Leave the IA Series about 30 minutes after turning on the power.
The circuit is not stable immediately after the power turns on, so the display
value may gradually drift.
Laser warning labels
The following diagrams show the type and position of laser warning labels
according to the IA Series.
It indicates additional information on proper operation.
It indicates tips for better understanding or useful information.
Safety Information for IA series
This product is just intended to detect the object(s). Do not
•
use this product for the purpose to protect a human body or a
part of human body.
This product is not intended for use as explosion-proof
•
product. Do not use this product in a hazardous location and/
or potentially explosive atmosphere.
Safety precautions on laser product
This product employs a semiconductor laser for its light
•
source.
Use of controls or adjustments or performance of procedures
•
other than those specified herein may result in hazardous
radiation exposure.
Follow the instructions mentioned in this manual. Otherwise,
•
injury to the human body (eyes and skin) may result.
Do not disassemble this product. Laser emission from this
•
product is not automatically stopped when it is disassembled.
Precautions on class /2 laser products
Do not stare into the beam.
•
Do not direct the beam at other people or into areas where
•
other people unconnected with the laser work might be
present.
Be careful of the path of the laser beam.
•
If there is a danger that the operator may be exposed to the
laser beam reflected by specular or diffuse reflection, block
the beam by installing an enclosure with the appropriate
reflectance.
Install the products so that the path of the laser beam is not
•
as the same height as that of human eye.
Precaution on class 1 laser products
Do not stare into the beam.
•
Model IA-030 IA-065/100
Wavelength 655 nm 655 nm
FDA(CDRH)
Part1040.10
IEC 60825-1
* The classification is implemented based on IEC60825-1 following the requirement of
Item Description
Laser Class
Output 220 μW560 μW
Laser Class Class 1 Laser Product Class 2 Laser Product
Output 220 μW560 μW
Laser Notice No.50 of FDA (CDRH).
Class 1 Laser Product
*
Class Laser Product
The IEC warning/explanatory labels are only included with Class 2 laser
products.
When using this product in the countries and/or regions other than U.S., use the
IEC warning/explanatory label in the package of this product.
In this case, it can be affixed on the FDA (CDRH) warning label, which has
already been affixed to this product.
1
IA Series-IM_E
Precautions on Regulations and Standards
0.5V
MODE
SEL
SET
LASER
OUT
ZERO
CLP
BANK
CENTER
4V
series
IA
z IA-1000
Amplifier x1
Instruction manual x1
z IA-030/065/100
Sensor head x1
Mounting bracket x1
Insulating sheet x1
Flat nut x1
M3 x L30 screw x2
Laser warning sticker* x1
* This is not included with IA-030.
1
3
2
Amplifier mounting bracket
Analog voltage output
(0.5 to 4 V)
Brown
Blue
Black
Shielded
Pink
*
Purple
Analog voltage output
(GND)
External input
Laser emission
stop input
10 to 30 VDC
CE Marking
Keyence Corporation has confirmed that this product complies with the essential
requirements of the applicable EC Directive, based on the following
specifications.
Be sure to consider the following specifications when using this product in the
Member State of European Union.
z EMC Directive(2004/108/EC)
• Applicable standard EMI : EN61326-1, Class A
• The length of cable connected to the power supply connector must be less
than or equal to 30m.
• For the Analog voltage output cable, adopt two ferrite cores under following
conditions.
Location : 200 mm or less from the end of Analog voltage output cable.
Ferrite core : ZCAT2035-0930, Manufactured by TDK (5 turns)
Remarks:
These specifications do not give any guarantee that the end-product with this
product incorporated complies with the essential requirements of EMC Directive.
The manufacturer of the end-product is solely responsible for the compliance on
the end-product itself according to EMC Directive.
UL Certificate
This product is an UL/cUL Recognized component.
• UL File No. E301717
• Category NRKH2, NRKH8
Be sure to consider the following specifications when using this product as an
UL/cUL recognized component.
• Use the power supply with Class 2 output defined in NFPA70 (NEC: National
Electrical Code).
• Power supply, Control input and Analog voltage output circuits shall be
connected to a single Class2 source only.
• Use with over current protection device which is rated 30V or more and not
more than 1A.
EMS : EN61326-1
SFT36SN, Manufactured by TKK (2 turns)
Mounting and Wiring the Sensor Amplifier
Mounting the sensor amplifier
Mounting the IA-1000
1 Align the claw at the bottom of the
main body with the DIN rail. While
pushing the main body in the
direction of the arrow 1, slant it in the
direction of the arrow 2.
2 To dismount the sensor, raise the
main body in the direction of the
arrow 3 while pushing the main body
in the direction of the arrow 1.
When using the amplifier mounting bracket
(OP-76877) (sold separately), mount it as
shown in the diagram to the right.
Amplifier wiring
The following information shows the I/O cable.
"I/O Circuit Diagram" (page 6)
* The external input switches as shown below
depending on the amplifier settings.
• bnK .. ........ Bank switching
• SFt .. ........ Zero shift
• oFF .......... Input off
Checking the Package Contents
Check if the parts and equipment listed below are included in the package of the
model you purchased before using the unit.
Sensor amplifier Sensor head
We have thoroughly inspected the package contents before shipment. However,
in the event of defective or broken items, contact your nearest KEYENCE office.
IA Series-IM_E
2
Connecting and Mounting the Sensor Head
Laser receiver
Mounting area
LASER
(Laser radiation
emission indicator)
OUT
(Analog indicator*
1
)
Mounting area
CENTER
(Reference distance*
2
)
Laser transmitter
Connector
Insulating sheet
Sensor head
M3 screw
(supplied accessory)
z Mounting when detecting
targets close to a wall
z Mounting when detecting
targets in a hole
• Receives little
effect from stray
laser light.
• Variations in the
detection value
with effects from
stray laser light.
• The target cannot be
detected when the
transmitter or receiver
are blocked.
z When detecting uneven workpieces
• Stable detection
even on uneven
areas.
• Incorrect values
can be detected
on the uneven
areas.
Current value (mm) display (red
)
Arrow buttons
Analog indicator
*1
(red)
Laser radiation emission
indicator (green)
[SET] button
LED bar
*3
[MODE] button
Zero shift input indicator
*4
(red)
Bank input indicator
*6
(green)
Reference distance indicator
*5
(green)
CLP function indicator*2
(red)
4V 2.25V 0.5V
Full range of analog output.
* When the current value is "---" ,"FFF", or "ErH", the LED bar turn
off totally, and when the current value is "uuu", the LED bar holds
the immediately preceding value.
Sensor Amplifier
Sensor head part names
IA-030
*1 The analog indicator lights up when the analog output is within the range and turns off
when the output is out of range.
"5. Analog output scaling (Bank A/B)" (page 6)
*2 The reference distance indicator lights up when the measurement distance is IA-
030:30 ± 0.25 mm, IA-065:65 ± 0.5 mm, IA-100:100 ± 1 mm
.
Connecting the sensor head
1 Unlock the sensor head
connector and insert it into
back of the amplifier.
2
Turn the round part of the
connector clockwise until a
clicking sound is heard to lock
it.
When shortening the sensor head cable,follow the instructions
given in the "Sensor Head Connector Assembly Manual" included
with the sensor head.
Sensor amplifier part names
*1 The analog indicator lights up when the analog output is within the range and
turns off when the output is out of range.
"5. Analog output scaling (Bank A/B)" (page 6)
*2 This indicator lights up when the clamp function is turned on.
"3. Clamp function setting" (page 5)
*3
The LED bar changes according to the analog output.
*4 Turns on while the zero shift function is performed (until the zero shift function is
reset), and turns off while the shift function is canceled.
*5 The reference distance indicator lights up when the
030:30 ± 0.25 mm, IA-065:65 ± 0.5 mm, IA-100:100 ± 1 mm.
*6 "Bank switching" (page 4)
measurement distance is IA-
Main screen
Mounting the sensor head
Attach the sensor head using the dedicated mounting bracket. If you do not use the
dedicated mounting bracket, be sure to place the supplied insulating sheet between
the mounting surface and the sensor head as shown below. (The insulating sheet is
not required when the dedicated bracket is use.)
For the IA Series, the optical axis may vary by approximately
±2.0°.
The main screen can be switched between "Current value display" and "Peak/bottom
value display". The main screen can be switched even during keylock.
Current value display screen
Current value (mm)
CENTER
SET
BANK
Peak/bottom value display screen
The screen switches automatically in the following order.
CENTER
SET SET
BANK
CENTER
SET
BANK
* While the peak or bottom value is displayed, press the up arrow key to reset.
Pressing the [Up] and [Down] arrow buttons simultaneously on the Current value
display screen forces the current value to 0.
MODE
or
Bottom value
CENTER
BANK
Peak value
CENTER
SET
BANK
MODE MODE
MODE MODE
3