PORTABLE CLIMATISEUR
OWNER’S
GUIDE
MODEL •
DPA140HCB1WDD
Danby Products Ltd., Guelph, ON, Canada N1H 6Z9
www.goedekers.com 13.11.14
Danby Products Inc, Findlay, Ohio USA 45840
1-800-263-2629 (1-800-26-DANBY)
DO NOT |
RETAILER |
Dear valued |
fulfills all |
your |
|
Please contact us |
for any inquiries |
|
|
NE PAS |
LE |
DÉTAILLANT SANS CONSIGNES SUPPLÉMENTAIRES
Cher(ère) client(e) important(e), nous espérons que votre produit Danby répond à tous vos besoins. Votre satisfaction est notre priorité!
Veuillez nous contacter au numéro gratuit de service après-vente, si vous avez des questions quelconques à propos de votre nouvel appareil.
NO DEVUELVA ESTA UNIDAD A LA TIENDA SIN
INSTRUCCIONES ADICIONALES
Estimado cliente, esperamos que el producto Danby que ha comprado satisfaga completamente sus necesidades. Su satisfacción
es nuestra prioridad!
Por favor, contáctenos gratuitamente a nuestro número de Servicio al Cliente para cualquier pregunta que tenga sobre su nuevo electrodoméstico.
www.goedekers.com
Danby 28.08.2014
TO OBTAIN WARRANTY SERVICE YOU MUST PROVIDE A VALID PROOF OF PURCHASE. PLEASE STAPLE YOUR RECEIPT TO THIS PAGE FOR FUTURE REFERENCE.
POUR OBTENIR LE SERVICE SUR GARANTIE, VOUS DEVEZ FOURNIR UNE PREUVE D’ACHAT VALIDE. VEUILLEZ AGRAFER VOTRE REÇU À CETTE PAGE POUR RÉFÉRENCE
IMPORTANT
This product is factory |
grounded plug. It must |
be plugged into a mating |
Electrical Code and |
applicable local codes |
receptacle, it is the |
responsibility and |
accordance with the |
National Electrical Code |
prong should not, |
under any circumstances, |
when they show |
any sign of damage. Do |
checked and test- |
ed by a qualified electrician or electrical supplier. |
|
IMPORTANT - MÉTHODE POUR LA MISE À LA TERRE
Ce produit arrive d’origine avec un cordon d’alimentation équipé d’une prise à trois fiches. Il doit être branché dans une prise avec une fiche de mise à la terre en conformité avec le Code national de l’électricité et les codes et règles locaux applicables. Si la prise murale n’a pas de mise à la terre, il est de la responsabilité du client de changer la prise existante pour la rendre conforme au Code national de l’électricité et aux codes et règles locaux applicables. La fiche de mise à la terre ne doit pas, en aucune circonstance, être coupée ou retirée. Si vous apercevez des signes de dommage, n’utilisez jamais le cordon d’alimentation, la prise ou l’appareil. N’utilisez jamais l’appareil avec une rallonge sauf si elle a été vérifiée et testée par un électricien qualifié ou un fournisseur de matériel électrique.
www.goedekers.com
CONTENTS
TABLE DES MATIÈRES
PORTABLE AIR CONDITIONER |
1-16 |
Owner’s Use and Care Guide ................................ |
• Welcome
• Important Safety Information
• Features
• Installation Instructions
• Operation Instructions
• Care and Maintenance
• Troubleshooting
• Warranty
CLIMATISEUR
Guide d’utilisation
•Bienvenue
•Consignes de
•Caractéristiques
•Consignes
•Consignes
•Soins et entretien
•Dépannage
•Garantie
CAUTION:
Read and follow all safety rules and operating instructions before first use of this product.
AVERTISSEMENT :
les consignes de d’utilisation avant
produit.
the grounding plug can shock and/or injury to
the appliance. Check with representative if in doubt that
grounded.
terre mal branchée peut de choc électrique
personnes qui utilisent
pas certain que l’appareil terre, consultez un
é.
Model • Modèle
DPA140HCB1WDD / DPA140HUB1WDD
www.goedekers.com
Welcome
Welcome to the Danby family. We are proud of our quality products, and we believe in dependable service, like you will find in this Owner’s Use and Care Guide, and like you will receive from our friendly customer service department. Best of all, you will experience these values each and every time you use your Danby appliance. That is important, because your new appliance will be a part of your family for a long time.
Note the information below; you will need this information to obtain service under warranty. To receive service, you must provide the original receipt.
Serial Number:
Date
to help
us
Read
It
If
Save
Check before calling. This section helps you solve common problems that may occur.
If you do need service, you can relax, knowing help is only a phone call away.
1-800-26- (1-800-263-2629)
www.goedekers.com
1
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation resulting from ignoring these instructions may cause harm or damage.
SAFETY PRECAUTIONS
ALWAYS DO THIS
Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug unit immediately if this occurs.
Always transport your air conditioner in a vertical position and place on a stable, level surface during use. If the unit is transported laying on its side it
. If the power cord is
.
with a clearance of at
off the unit and
the unit on or off.
room air. Always ensure ciently.
such as a bathroom or
Do not touch the unit with wet or damp hands.
Do not press the buttons on the control panel with anything other than your fingers.
Do not remove any fixed components. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
Never use the plug to start and stop the unit.
Do not cover or obstruct the inlet or outlet grilles.
Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapour such as alcohol, insecticides, gasoline, etc.
Do not allow children to operate the unit unsupervised.
Do not use this product for functions other than those described in this instruction manual.
www.goedekers.com
2
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation resulting from ignoring these instructions may cause harm or damage.
ENERGY SAVING TIPS
•Use the unit in the recommended room size.
•Locate the unit where furniture cannot obstruct the air flow.
•Keep blinds/curtains closed during the sunniest part of the day.
•Keep the filters clean.
•Keep doors and windows closed to keep cool air in and warm air out (cooling mode)
OPERATING
CONDITIONS
TOOLS FOR
WINDOW KIT
INSTALLATION
Identifying
ELECTRICAL INFORMATION
temperature range
TEMPERATURE
(62°F) ~ 35°C (95°F)
(55°F) ~ 35°C (95°F)
(41°F) ~ 30°C (86°F)
<30°C / 86°F
these operating tempera-
be cut down in size installation).
guide
WARNING
•Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
•Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
WARNING
•Be sure the electrical supply is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grill.
•Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
•Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
•Ensure the receptacle remains accessible after the unit is installed.
www.goedekers.com
3
Identifying Parts
ACCESSOIRES
PARTS
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
•Check all the their usage.
NOTE: All the illustrations different.
UNIT STRUCTURE
Fig.1
PART NAME |
QUANTITY |
Exhaust hose and adapotor; |
1 set |
window slider kit and screws |
|
Foam seal |
6 pieces |
Remote controller and battery |
1 ensemble |
|
piece |
|
|
instructions for
may be slightly
1 Control Panel
2 Horizontal louver blade (adjusts automatically)
3 Caster
4 Carrying handle (both sides)
www.goedekers.com
4
Identifying Parts
|
REAR |
Upper air filter (behind(Behindthegrill)l) |
|
5 |
|
Fig.2 |
6 |
Upper air intake |
|
7 |
Air outlet |
|
8 |
Drain outlet (only for pump heating model) |
|
9 |
Power cord outlet |
|
|
buckle (used only when storing |
|
|
outlet |
|
|
socket (use only when storing |
|
|
(behind the grill) |
Features
ELECTRONIC
INSTRUCTIONS
Before you begin, thoroughly |
and all its functions. Select |
the functions you desire |
|
The unit can be controlled |
|
Note: This manual does not include Remote Controller Operation. See the Remote Controller Instructions packed with the unit for this information.
Fig.3
8
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
2 |
|
1 |
|
|||
|
7 |
|
6 |
|
5 |
|
|
4 |
|
3 |
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
www.goedekers.com
5
Features
ELECTRONIC CONTROL INSTRUCTIONS
1POWER button
Turns power on/off.
2SLEEP button
Used to initiate the SLEEP operation.
3FAN button
Controls the fan speed. Press to toggle between three fan speeds: LOW (press 1 time), MEDIUM (press 2 times) and HIGH (press 3 times). The fan speed indicator light indicates the corresponding fan setting. Press the button a fourth time to initiate AUTO-FAN mode. In this mode, all three indicator lights will light up.
settings 30°C(86°F) control is
Fahrenheit or press and
for 3 seconds.
you press goes from
indicator light
OFF stop time program,
(select models only) Used to initiate the Auto swing feature. When operating press the SWING button to stop the louver at the desired angle.
8LED DISPLAY
Shows the set temperature in °C or °F and the Auto-timer settings. While on DRY and FAN modes, it shows the room temperature.
Error codes:
E1 - Room temperature sensor error -Unplug the unit and plug it back in. If error repeats, call for service.
E2 - Evaporator temperature sensor errorUnplug the unit and plug it back in. If error repeats, call for service.
E3 - Condenser temperature error - Unplug the unit and plug it back in. If error repeats call for service.
E4 - Display panel communication error - Unplug the unit and plug it back in. If error repeats call for service.
P1 - Bottom tray is full - Connect the drain hose and drain the collected water away. If error repeats, call for service.
www.goedekers.com
6
Operating Instructions
OPERATING MODES
COOL mode
-Press the “MODE” button until the “COOL” indicator light comes on.
-Press the UP or DOWN arrow buttons to select your desired
room temperature. The temperature can be set within a range of 17°C-30°C / 62°F-86°F.
- Press the “FAN SPEED” button to choose the fan speed.
HEAT mode
-Press the “MODE” button until the “HEAT” indicator light comes on.
-Press the ADJUST buttons “up” and “down” to select your desired room temperature. The temperature can be set within a range of 17°C-30°C / 62°F-86°F.
-Press the “FAN SPEED” button to choose the fan speed. For some models, the fan speed cannot be adjusted under HEAT mode.
automatically select coolyou have selected and
automatically to the tem-
comes on.
(1 time for LOW, -FAN).
speed lights up. All
press the Timer
-To initiate the “Auto-start” program: When the unit is off, press the Timer button, the TIMER ON indicator light will illuminate.
-Press or hold the “UP” or “DOWN ” buttons to change the Auto-time by 0.5 hour increments, up to 10 hours, then by 1 hour increments up to 24 hours.The control will count down the time remaining until the unit starts.
-The selected time will register in 5 seconds and the system will automatically revert back to display the previous temperature setting.
-Turning the unit ON or OFF at any time or adjusting the timer setting
to 0.0 will cancel the Auto Start/Stop timed program.
- When a malfunction (E1,E2,E3, E 4 or P1) occurs, the Auto Start/Stop timed program will also be cancelled.
SLEEP function
Simply press the sleep button. When in cooling mode, the temperature will increase by 1°C / 2°F every half hour for 1 hour. The unit will then hold this new temperature for 7 hours before returning to the original temperature setting and resuming normal operation.
NOTE: This feature is unavailable in FAN and DRY mode.
www.goedekers.com
7
Operating Instructions
POWER OUTAGE
AIR FLOW DIRECTION ADJUSTMENT
In the case of a power outage or interruption, the unit will automatically re-start with the default settings after the power is restored.
Wait 3 minutes before resuming operation
After the unit has stopped, it cannot operate for the first 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.
airflow direction.
to initiate the Auto
Fig. 4
www.goedekers.com