Danby DPAC7099 User Manual

Loading...

Owner’s Use and Care Guide

Guide de soin d’utiliser-et

Model • Modèle

DPAC 7099

CAUTION: Read and follow all safety rules and operating instructions before first use of this product.

MISE EN GARDE : Veuillez lire attentivement les consignes de sécurité et les directives d'utilisation avant l'utilisation initiale de ce produit.

PORTABLE AIR CONDITIONER

 

Table of contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

CLIMATISEUR PORTATIF

 

Table des matières . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE: If the unit changes ownership, be sure this manual accompanies the unit.

CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEURE: En cas de revente du l’unité, ce manuel doit être inclus avec l’appareil.

Danby Products Ltd, PO Box 1778, Guelph, Ontario Canada N1H 6Z9

Danby Products Inc, PO Box 669, Findlay, Ohio USA 45839-0669

Version 1.11.08 JF

TABLE OF CONTENTS

UNIT SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.2

PART IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.3

IMPORTANT SAFETY INFORMATION

 

Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.3

Energy Saving Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.4

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.5

Window Kit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.5

OPERATION

 

Features of the Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.6

Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 7

Draining Excess Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Air Conditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 8

Dehumidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 9

Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

1

WELCOME

Thank you for choosing a Danby appliance to provide you and your family with all of the “Home Comfort” requirements of your home, cottage, or office. This Owner’s Use and Care Guide will provide you with valuable information

necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.

Your Danby Portable Air-Conditioner is a multi-functional room air-exchanging, air-processing appliance, designed to offer you the functions of; Air Conditioning, Dehumidifying, and Independent Fan. Each individual mode is featured with “oscillating” air swing capabilities. This unit can be conveniently moved from room to room within your home and set up in just minutes. Imagine the convenience of 4 Season Home Comfort at your fingertips, anywhere, anytime.

For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturers nameplate on the rear panel of the unit.

Model Number:

Serial Number:

Date of Purchase:

This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a Customer Service Representative, call Danby

TOLL FREE: 1-800-26- (1- 800-263-2629)

UNIT SPECIFICATIONS

Unit Specifications

 

 

Model Number

DPAC7099

 

 

Voltage/Frequency

115V-60Hz

 

 

Noise Level

50 dB

 

 

Fan Speeds

3

 

 

 

Airflow CFM High / Medium / Low

282 / 252 / 222

 

 

 

Cooling Capacity

7000BTU

 

 

 

Refrigerant

R410A

 

 

Unit Weight

24.5 kg (53.9 lbs)

 

 

Dimensions (inches) W x H x D

17 1/3”x 12”x 27 1/6

 

 

Dimensions (mm) W x H x D

440 x 305 x 690

 

 

Remote Control

Yes

 

 

Time of Day Clock

No

 

 

 

Auto-Timer

Yes

NOTE: Continuing research results in steady improvement. Therefore, this information and these specifications are subject to change without notice.

2

PART IDENTIFICATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Outlet

 

 

 

 

 

 

 

Air Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Intake

 

 

 

On/Off

 

Handles

 

 

(Evaporator)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water outlet for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

continuous drain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Intake

 

 

 

 

 

 

 

 

 

(condenser)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Outlet

 

 

 

 

 

 

 

 

 

 

drain

 

 

 

 

 

Castors

Air Outlet

 

 

 

 

 

 

 

 

 

 

(Heat Exhaust)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply Cord

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT SAFETY INFORMATION

READ ALL SAFETY INFORMATION BEFORE USING

ELECTRICAL

SPECIFICATIONS

1)Check available power supply and resolve any wiring problems BEFORE installation and operation of this unit. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2)This appliance draws 7.0 nameplate amps under Cooling Mode and may be used in any properly wired, general purpose 15 amp household grounded receptacle.

3)For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult a qualified electrician.

WARNING: Improper connection of the grounding plug can result in risk of Fire, Electric Shock, and/or injury to Persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is proplery grounded.

4)DO NOT USE PLUG ADAPTERS OR EXTENSION CORDS WITH THIS UNIT. If it is necessary to use an extension cord with this unit, use an approved “air conditioner” extension cord only (available at most local hardware stores).

5)To avoid the possibility of personal injury, always disconnect the power supply to the unit before installing and/or servicing.

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

7.0

18

AWGAmerican Wire Gauge

*Based on copper wire at 105°C temperature rating.

TABLE 2

Receptacle and Fuse Types

Rated Volts

125

Amps

15

Wall Outlet

 

 

 

 

 

 

 

Fuse Size

15

 

 

 

 

 

 

Time Delay Fuse

Plug Type

(or Circuit Breaker)

 

 

 

 

 

CAUTION: Do not leave this unit unattended in a space where people or animals cannot react to a failed unit are located. A failed unit can cause extreme overheating or death in such an enclosed, unattended space.

3

IMPORTANT SAFETY INFORMATION

POWER SUPPLY The power cord supplied with this air conditioner contains a device

CORD

that senses damage to the power cord. To test if your power cord is

working properly, you must do the following:

 

1)Connect the power supply cord to an electrical outlet.

2)The power supply cord has two buttons located on the head of the plug. One button is marked “TEST”, and the other is marked “RESET”. Press the “TEST” button; you will hear a click as the “RESET” button pops out.

3)Press the “RESET” button; you will hear a click as the button engages.

4)The power supply cord is now energized and supplying electricity to the air conditioner (on some products this is also indicated by a light on the plug head).

NOTE: The power cord supplied with this air conditioner contains a current leakage detection device designed to reduce the risk of fire. In the event the power supply cord is damaged, it cannot be repaired and must be replaced with a new cord from the product manufacturer.

Under no circumstances should this device be used to turn the unit on or off.

The “RESET” button must always be pushed in (engaged) for correct operation.

The power supply cord must be replaced if it fails to reset when the “TEST” button is pushed in.

ENERGY-SAVING

Your Danby appliance is designed to be highly efficient in

energy savings. Follow these recommendations for greater

TIPS

efficiency.

 

 

 

4) Start your air conditioner before the

1) Select a thermostat setting that suits your

outdoor air becomes hot and uncomfortable,

comfort needs and leave at that chosen

to avoid an initial period of discomfort while

setting.

 

the unit is cooling off the room. Use of the

2) The air filter is very efficient in removing

automatic start/stop programmable TIMER

feature can be a major asset in this regard if

airborne particles. Keep the air filter clean at

utilized to the fullest extent.

all times.

 

5) When outdoor temperatures are cool

3) Use drapes, curtains or shades to keep

enough, turn the air conditioner off and use

direct sunlight from penetrating and heating

the FAN MODE. This circulates indoor air,

room, but do not allow drapes or curtains to

providing some cooling comfort while utilizing

obstruct the air flow around the unit.

less electricity.

4

Danby DPAC7099 User Manual

INSTALLATION

ELECTRIC SHOCK HAZARD: To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.

FIG 1. INSTALLATION ACCESSORIES

Flexible Exhaust Hose (13cm), Exhaust nozzle connector (Fix to unit)

(1pc).....................................................1/set

Adjustable window door slider kit (3 pcs).....

from

28 1/3”(72cm) up to 80” (203cm)

 

Fixture.....

(1 pcs)

Screws......

(8 pcs)

NOTE: The exhaust/window kit must be installed at all times when the unit is operating under AIR CONDITIONING mode.

There should be at least 11.8” (30cm) clearance between the unit and any other objects or building structures, and should be installed on a level surface. The unit does not have to be vented outside during Dehumidifying or Fan Only mode operation.

Instructions for Assembling the Window Adapter KitFig. 2

1)Insert tube adapters through the back of the window panel.

2)Secure each tube adapter with four screws through the front of the window panel.

3)Insert window panel extensions into window panel. Lightly tighten the screws in the window panel to hold the extensions in place.

WINDOW

KIT

Fig. 1

Fig. 2

Back of Window Pane

Tube Adapters

Air Conditioning Mode ONLY

Your window kit has been designed to fit most standard “vertical”/”horizontal” windows up to a maximum height of 80” (203cm). For vertical window applications, multi lock positions are provided on the edge of each slider section to secure each sliding section together.

1)Select a suitable location, making sure you have access to an electrical outlet.

2)Install the flexible hose to the rear side of the unit. Insert the hose collar on top of the exhaust opening and twist to lock into position.

3)Install the adjustable Window Slider Kit as required (see Fig. 3a & 3b).

4)Install the opposite end of the flexible exhaust hose into the window exhaust adapter.

5)Install the window exhaust adapter into the opening in the slider section, making sure the window slider sections are secure.

6)Plug the unit into a 115V/60Hz grounded electrical outlet.

Horizontal Window

 

Window Slider Kit:

 

 

Min.: 28 1/3(72cm)

 

 

Max.: 80” (203cm)

 

 

Vertical

 

 

Window

Window Slider Kit:

 

 

Min.: 28 1/3(67.5cm)

Fig. 3a

Fig. 3b

Max.: 80” (203cm)

 

 

5

OPERATIONFeatures of the Control Panel

LCD

Display

Water Full

ON/OFF

Indicator

Switch

 

EMERGENCY ON/OFF Switch

This switch is used when unit needs to be temporarily switched on/off.

Pressing the emergency will turn on the unit. The running mode and fan speed mode will be set automatically.

Pressing the emergency button again will stop the unit.

Note: When the unit is on, remember to lift up the air outlet flap.

WATER FULL INDICATOR

When illuminated, signifies condensed water inside the unit can’t be discharged and the condensation water level has reached full water level.

The unit stops operating when this

indicator flashes. After discharging the water, press the POWER button to restart the unit. The operating mode will be that which was in operation before water full indicator illumination.

• LED light colour is RED

LCD DISPLAY

Cooling Mode

Dehumidify Mode

Fan only Mode

Auto Mode

High Fan Speed

Medium Fan Speed

Low Fan Speed

Display set temperature

Display timer setting of auto switch On/Off

Mode Control

The Mode Control has 4 settings:

• Cool • Dehumidify • Fan • Auto

The settings are adjusted by the Mode Control button

Fan Speed Control

The Fan Speed Control has 4 settings:

• Auto (Cool only) • High • Medium • Low

Temp. Set Controls

Press “ ” or “” to set temperature.

The setting ranges from 16°C (61°F) to 32°C (89°F).

Note: When choosing Auto, Dehumidify or Fan Mode, temperature setting button is invalid.