Braun 7899CC, 7897CC, 7898CC User Manual

0 (0)
Series 7
90951420/VI-16
Type 5696 Modèle 5696 Modelo 5696
www.braun.com
7899cc 7898cc 7897cc
Braun Infolines Lignes d’assistance Braun Líneas de información de Braun
English 6
Français 20
Español 33
Thank you for purchasing a Braun product. We hope you are completely satisfied with your new Braun shaver. If you have any questions, please call: US residents 1-800-BRAUN-11 1-800-272-8611 Canadian residents 1-800-387-6657
Merci d’avoir fait l’achat d’un produit Braun. Nous espérons que vous serez entièrement satisfait de votre nouveau rasoir Braun. Si vous avez des questions, veuillez appeler Braun Canada : 1-800-387-6657
Gracias por haber comprado un producto Braun.
EN/FR/ES
t
r
i
m
m
e
r
Ser
ies
7
S e
r ie
s 7
Se
rie
s 7
34
Series 7
8
Series 7
Series 7
9
10
5
11
12 13
trimmer
trimmer
trimmer
trimmer
trimmer
trimmer
n o
on
off
off
wet & dry
2 1
6
14
7
15
16
16a 16b 16c 16d
20
h
y
y
g
r
i
e
e
t
t
n
a
e
b
17
h
y
y
g
r
i
e
e
t
t
n
a
e
b
19
y r
d
&
et
w
18
3
tr
immer
r
e
l
e
a
s
e
r im
tr
S
eries 7
2
1
+
trimmer
lock
lock
lock
re l
e a se
lock
90°
me
trim
me
r
Series
r
e
l
e
a
s
e
r
Series
re
le
a
s
e
mer
S
e
Series 7
rie
s
Series 7
Series
r
e
le
a
s
e
mer
4
Series 7
S
eri
Se
r
ies 7
es
7
re
le
a
s
e
Series 7
re
le
a
s
e
1
t
rimmer
2
n
a
f
e
l
a
c
s
t
n
a
e
f
l
a
c
t
s
t r i
m me
r
Se
r
ies 7
n
a
f
e
l
a
c
s
t
n
a
e
f
l
a
c
t
s
n
a
e
f
l
a
c
t
s
5
English
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following:
Read all instructions before using this appliance.
When disconnected, the hand-held part of this shaving appliance may be used in a bath or shower. For safety reasons, the appliance can only be operated cordless.
DANGER
To reduce the risk of electric shock:
1. The charger unit is not for immersion in water or for use in shower.
2. Do not reach for a charger that has fallen into water. Unplug immediately.
3. Do not place, store or charge the appliance where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid.
4. Except when charging, always unplug this appliance from the electrical outlet immediately after using.
5. This appliance is provided with a special cord set with integrated Safety Extra Low Voltage power supply. Do not exchange or manipulate any part of it.
6. Do not use an extension cord with this appliance.
7. Unplug this appliance before cleaning.
6
WARNING
To reduce the risk of burns, fire, electric shock, or injury to persons:
1. Close supervision is necessary when this appliance is used by, on, or
near children or persons with disabilities.
2. Use this appliance only for its intended use as described in this
manual. Do not use attachments not recommended by the manufacturer.
3. Never operate this appliance if it has a damaged cord or plug, if it is
not working properly, if it has been dropped or damaged, or if the power supply has been dropped into water. Return the appliance to a service center for examination and repair.
4. Keep the cord away from heated surfaces.
5. Never drop or insert any object into any opening of the appliance.
6. Do not use outdoors or operate where aerosol (spray) products are
being used or where oxygen is being administered.
7. Do not use this appliance with a damaged or broken foil, as serious
skin injuries may occur.
8. Always attach plug to appliance first, then to outlet. To disconnect,
turn all controls off, then remove plug from outlet.
9. When plugging to an electrical outlet outside North America, use a
plug adapter to match the outlet’s pin configuration.
10. Caution: The battery used in this device may present a fire or
chemical burn hazard if mistreated. Do not disassemble, heat above 100 °C (212 °F), or incinerate.
11. Only use the special electric cord set provided with the appliance.
SAVE THESE INSTRUCTIONS
7
Our products are designed to meet the highest standards of quality, functionality and design. Thank you for your trust in Braun’s quality, and we hope you enjoy your new Braun shaver.
This product is for household use only.
Warning Clean&Charge Station
To prevent the cleaning fluid from leaking, ensure that the Clean&Charge Station is placed on a flat surface. When a cleaning cartridge is installed, do not tip, move suddenly or transport the station in any way as cleaning fluid might spill out of the cartridge.
Do not place the station inside a mirror cabinet, nor place it on a polished or lacquered surface.
The cleaning cartridge contains a highly flammable liquid so keep it away from sources of ignition. Do not expose to direct sunlight and cigarette smoking nor store it over a radiator.
Do not refill the cartridge and use only original Braun refill cartridges.
Description
Clean&Renew station 1 Cleaning fluid display 2 Lift button for cartridge exchange 3 Station-to-shaver contacts 4 Start button 5 Cleaning program indicators 6 Station power socket 7 Cleaning cartridge (not with all
models)
Shaver 8 Foil & Cutter cassette 9 Cassette release button 10 Shaver head lock switch
11 Pop-out long hair trimmer 12 On/off switch 13 – setting button (sensitive) 14 + setting button (intensive) 15 Reset button 16 Shaver display 16a Battery segments 16b Hygiene segments 16c Low charge indicator 16d Replacement symbol 17 Shaver-to-station contacts 18 Shaver power socket 19 Travel case 20 Special cord set (design can differ)
Before shaving
Prior to first use you must connect the shaver to an electrical outlet using the special cord set (20) or alternatively proceed as below.
Installing the Clean&Renew station
Press the lift button (2) to open the housing.
Hold the cleaning cartridge (7) down on a flat, stable surface (e.g. table).
8
Carefully remove the lid from the cartridge.
Slide the cartridge into the base of the station as far as it will go.
Slowly close the housing by pushing it down until it locks.
Using the special cord set (20), connect the station power socket (6) to an electrical
outlet.
The cleaning fluid display (1) will show how much fluid is in the cartridge:
up to 30 cleaning cycles available up to 7 cleaning cycles remaining new cartridge required
Charging and cleaning the shaver
Insert the shaver head with the front showing and released head lock (10) into the Clean&Renew. The contacts (17) on the back of the shaver will align with the contacts (3) in the cleaning station. Important: The shaver needs to be dry and free from
any foam or soap residue!
If required, the Clean&Renew station will automatically charge the shaver. The hygiene status of the shaver will also be analyzed and one of the following cleaning program indicators (5) will light up:
shaver is clean short economical cleaning required
normal level of cleaning required
high intensive cleaning required
If the station selects one of the required cleaning programs, it will not start unless you press the start button (4). For best shaving results, we recommend cleaning after
each shave.
Each cleaning program consists of several cycles, where cleaning fluid is flushed through the shaver head. Depending on your Clean&Renew Station model and/or program selected, the cleaning time takes up to 16 minutes. Leave the shaver in the station for drying. It takes several hours until remaining moisture evaporates depending on the climatic conditions.
When the program is finished, the blue indicator will light up.
Stand-by mode
10 minutes after completing the charging or cleaning session, the Clean&Renew station switches to the stand-by mode: The indicators of the Clean&Renew station turn off.
Shaver display
The shaver display (16) shows the charge status of the battery on the left, and the hygiene status on the right. 6 dark segments are shown on each side when the battery is fully charged and the shaver is hygienically clean.
9
Battery segments
During charging or when using the shaver, the respective battery segment (16a) will blink. When fully charged all 6 segments are shown. With decreasing charge the segments gradually disappear.
Low charge indicator The low charge indicator (16c) provided with a red frame blinks to indicate that the battery is running low. The remaining battery capacity is sufficient for 2 to 3 shaves.
Hygiene segments
All 6 hygiene segments (16b) will appear after the shaver has been cleaned in the Clean&Renew station. When the shaver is being used, the hygiene segments will gradually disappear. Once the shaver is returned to the station, the system will automatically select the appropriate cleaning program and restore the segments to maximum hygiene. Given that rinsing the shaver under tap water is not as hygienic as the cleaning station, the hygiene segments will only restore themselves when the shaver has been cleaned in the Clean&Renew station.
Charging information
A full charge will take about 1 hour and provides up to 50 minutes of cordless shaving
time. This may vary according to your beard growth and environmental temperature. 5-minute quick charge is sufficient for a shave.
Recommended ambient temperature for charging is 41 °F to 95 °F / 5 °C to 35 °C.
The battery may not charge properly or at all under extreme low or high temperatures. Recommended ambient temperature for shaving is 60 °F to 95 °F / 15 °C to 35 °C. Do not expose the shaver to temperatures higher than 122 °F / 50 °C for extended periods of time.
Using the shaver
How to use
Press the on/off switch (12) to operate the shaver:
The pivoting shaver head and floating foils automatically adjust to every contour of
your face.
To shave hard to reach areas (e.g. under the nose), first slide the shaver head to the
back position, afterwards move the head lock switch to the back. The pivoting head is locked at this angle.
To trim sideburns, moustache or beard, slide the pop-out long hair trimmer (11)
upwards.
Tips for the perfect dry shave
For best shaving results, Braun recommends you follow 3 simple steps:
1. Always shave before washing your face.
2. At all times, hold the shaver at right angles (90°) to your skin.
3. Stretch your skin and shave against the direction of your beard growth.
10
Personalizing your shaver
By holding down the accelerator button –/+ (13) or (14) you can adjust the shaving power to your individual needs in the different areas of your face from sensitive to intensive. The pilot light in the on/off switch ( 12 ) changes within the following range:
(–) sensitive shave – light blue – dark blue – green (+) intensive shave
For a thorough and fast shave we recommend the green (intensive) setting. When switching on next time, the last used setting will be activated.
Cleaning
Automatic cleaning
After each shave, return the shaver to the Clean&Renew station and proceed as described above in the section «Before shaving». All charging and cleaning needs are then automatically taken care of. With daily use, a cleaning cartridge should be sufficient for about 30 cleaning cycles.
The hygienic cleaning cartridge contains ethanol or isopropanol (specification see cartridge), which once opened will naturally evaporate slowly. Each cartridge, if not used daily, should be replaced after approximately 8 weeks to ensure optimal disinfection.
The cleaning cartridge also contains lubricants, which may leave residual marks on the outer foil frame after cleaning. However, these marks can be removed easily by wiping gently with a cloth or soft tissue paper.
Manual cleaning
Cleaning under running water
Switch the shaver on (cordless) and rinse the shaver head under hot running
water until all residues have been removed. You may use liquid soap without
abrasive substances. Rinse off all foam and let the shaver run for a few more seconds.
Next, switch off the shaver, press the release button (9) to remove the Foil & Cutter
cassette (8) and let it dry. The shaver shall not be used until it has dried completely.
If you regularly clean the shaver under water, then once a week apply a drop of light
machine oil (not included) on top of the Foil & Cutter cassette and the long hair trimmer.
The shaver should be cleaned after each foam usage.
Cleaning with a brush
Switch off the shaver. Remove the Foil & Cutter cassette (8) and tap it out on a flat
surface. Using a brush, clean the inner area of the pivoting head. However, do not clean the cassette with the brush as this may damage it.
11
Cleaning the housing
From time to time clean the housing of the shaver and the Clean&Renew station with a damp cloth, especially inside the cleaning chamber where the shaver rests.
Replacing the cleaning cartridge
After having pressed the lift button (2) to open the housing, wait for a few seconds before removing the used cartridge to avoid any dripping. Before discarding the used cartridge, make sure to close the openings using the lid of the new cartridge, since the used cartridge will contain contaminated cleaning solution.
Keeping your shaver in top shape
Replacing the Foil & Cutter cassette / reset
To maintain 100% shaving performance, replace the Foil & Cutter cassette (8), when the replacement symbol (16d) lights up on the shaver display (after about 18 months) or when cassette is worn. The replacement symbol will remind you during the next 7 shaves to replace the Foil & Cutter cassette. Then the shaver will automatically reset the display.
After you have replaced the Foil & Cutter cassette, use a ball-pen to push the reset button (15) for at least 3 seconds to reset the counter. While doing so, the replacement light blinks and goes off when the reset is complete. The manual reset can be done at any time.
Accessories
Available at your dealer or Braun Service Centres:
Foil & Cutter cassette 70S
Cleaning cartridge Clean&Renew CCR
Battery removal
This appliance contains a rechargeable battery. Before disposing of the appliance, disassemble the housing as shown, remove the rechargeable battery and recycle or dispose of properly, according to local guidelines. Caution: Disassembling the appliance will destroy it and invalidate the warranty.