ZOOM 507 Operation Manual

0 (0)

Operation Manual

Thank you for selecting the ZOOM 507 (hereafter simply called the "507").

Please take the time to read this manual carefully so you can get the most out of your 507 and ensure optimum performance and reliability.

Retain this manual for future reference.

ZOOM CORPORATION

NOAH Bldg., 2-10-2, Miyanishi-cho, Fuchu-shi, Tokyo 183, Japan

PHONE: 0423-69-7116 FAX: 0423-69-7115

Printed in Japan 507-5000

1 Major Features

High-grade reverb of top class devices despite compact size; delay with 990 ms maximum delay time; and outstanding spatial effects that produce a beautiful chorus sound at an affordable price.

On-board "Zfx-2" DSP (Digital Signal Processor) developed by Zoom, and an innovative design used solely for its powerful spatial effects. Demonstrates its power in home recording as well as in live performances.

You can switch between 24 patches to store diverse settings based on your preference.

Integrated auto-chromatic tuner for guitar. You can tune your instrument easily anywhere, any time. You can also leave the tuning function disabled all the time.

The optional FP01 expression pedal enables foot control of the mix level for the effect sound. The optional FS01 foot switch enables operation of the chorus ON/OFF switch.

Dual power supply design allows the unit to be powered from an alkaline battery (6LR61) or an AC adapter.

2 Safety Precautions

USAGE AND SAFETY PRECAUTIONS

In this manual, symbols are used to highlight warnings and cautions for you to read so that accidents can be prevented. The meanings of these symbols are as follows:

This symbol indicates explanations about extremelydangerous issues. If users ignore this symbol and handle the device incorrectly, serious injury or death could

Warning result.

This symbol indicates explanations about dangerousissues. If users ignore this symbol and handle the device the wrong way, bodily injury and damage to the

Caution equipment could result.

Please observe the following safety tips and precautions to ensure hazard-free use of the 507.

Usage precautions

Electrical interference

For safety considerations, the 507 has been designed to provide maximum protection against the emission of electromagnetic radiation from inside the device, and from external interference.However, equipment that is very susceptible to interference or that emits powerful electromagnetic waves should not be placed near the 507, as the possibility of interference cannot be ruled out entirely.

Whatever the type of digital control device, the 507 included, electromagnetic damage can cause malfunctioning and corrupt or destroy data. Since this is an ever-present danger, thorough care should be taken to minimize the risk of damage.

About power

Warning• Since power consumption of this unit is fairly high, we recommend the use of an AC adapter whenever possible. When powering the unit from a battery, use only an alkaline type.

AC adapter operation

Be sure to use only an AC adapter which supplies 9 V DC, 300 mA and is equipped with a "center minus" plug (Zoom AD-0006). The use of an adapter other than the specified type may damage the unit and pose a safety hazard.

Connect the AC adapter only to an AC outlet that supplies the rated voltage required by the adapter.

When disconnecting the AC adapter from the AC outlet, always grasp the adapter itself and do not pull the cable.

If the unit is not to be used for a long time, disconnect the AC adapter from the outlet.

Battery operation

Use only a 9 V (alkaline) battery (6LR61).

The 507 cannot be used for recharging.

Pay close attention to the labelling of the battery to make sure you choose the correct type.

If the 507 is not to be used for an extended period of time, remove the battery from the unit.

If battery leakage has occurred, wipe the battery compartment and the battery terminals carefully to remove all remnants of battery fluid.

While using the unit, the battery compartment cover should be closed.

Environment

Caution Avoid using your 507 in environments where it will be exposed to:

Extreme temperature

High humidity or moisture

Excessive dust or sand

Excessive vibration or shock

Cleaning

Use a soft, dry cloth to clean the 507. If necessary, slightly moisten the cloth. Do not use abrasive cleanser, wax, or solvents (such as paint thinner or cleaning alcohol), since these may dull the finish or damage the surface.

Connecting cables and input and output jacks

You should always turn off the power to the 507 and all other equipment before connecting or disconnecting any cables. Also make sure to disconnect all cables and the AC adapter before moving the 507.

Handling

Caution • The 507 is a precision instrument. Except for the foot switches, do not push other parts with your feet or subject them to strong force.

Take care that no foreign objects (coins or pins etc.) or liquids enter the unit.

Be sure to turn the power to all equipment off before making connections.

Before moving the unit, turn the power off and disconnect all cables and the AC adapter.

Alterations

Caution Never open the case of the 507 or attempt to modify the product in any way since this can result in damage to the unit.

ZOOM 507 Operation Manual

7

Selecting Patches

Bank switching

Banks A, b, C, d, E, F are available

PATCH PATCH

DOWN UP

Patch switching

24 patches are available

The 24 patches can be easily selected by pressing the patch pedals. The right patch pedal switches to the next patch and the left patch pedal switches to the previous patch.

In the initial condition, the 507 is set up so that the patch pedals select patches continuously, but you can also set up the unit so that patches are switched only within a certain bank of four patches. [For details, see section 9 Patch Switching (Application: Bank Hold ON).]

Banks are selected with the VALUE +/- keys. Press the VALUE+ key to select the next bank, and the VALUEkey to select the previous bank.

For example, to switch from Patch 2, Bank A to Patch 3, Bank C, the patch pedal would have to be pressed nine times. Instead, you can press the VALUE+ key twice to switch to Bank C, and then press the patch pedal (UP) just once to select Patch 3.

BANK UP

BANK DOWN

Bank/patch switching when Bank Hold is off (initial setting)

BANK F

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK E

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK d

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK C

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK b

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK A

PATCH 1

PATCH 2

PATCH 3

PATCH 4

8

Using the Bypass/Tuner Mode

The effects of the 507 can be turned off (bypassed) temporarily, so that only the original sound of the instrument is heard. In this mode, the auto-chromatic tuning function via the LED display is also active.

Bypass mode

Pressing both patch pedals simultaneously activates the Bypass mode.

Currently selected

patch is displayed

Press

Tuner ON/OFF

Pressing the EDIT key and the STORE key simultaneously for more than one second in Play mode will allow you to select whether or not to activate the tuning function in Bypass mode. When you change the setting, the display will show"tunEr oFF" (tuning function off) or "tunEr on" (tuning function on) according to the setting.

* The reference pitch (A) can be adjusted in the range from 435 to 445 Hz. When the BANK key is pressed in Bypass/Tuner mode, this is shown as "35" to "45" on the display for a second. Adjust to the suitable value. At power-on, the setting is 440 Hz (40).

Bypass ON/OFF

The bypass function is invoked by pressing the left and right Press both patch pedals simultaneously.

pedals together To cancel the Bypass/Tuner mode, just press one of the patch pedals.

Release immediately

Tuning function (only when the tuning function is ON)

To cancel the Bypass mode, simply press one of the patch pedals. The unit then reverts to the previously selected patch.

Tuner mode

The 507 is initially set so that the auto-chromatic tuning function for the guitar activates automatically when the Bypass mode is invoked. In Bypass mode, pick an open string to be tuned. The closest note will be shown on the display.

Input signal standby condition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

w

Regular tuning

 

 

 

 

 

Do = C

 

 

 

Re# = D#

 

 

 

 

 

Fa# = F#

 

 

 

La = A

5th string

&

 

w

 

&

# w

 

&

# w

 

 

&

 

 

 

 

Regular tuning

6th string

 

Regular tuning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do# = C#

 

 

 

Mi = E

 

 

 

 

So = G

 

 

 

# w

La# = A#

 

 

 

 

 

 

 

 

1st string

 

 

 

 

3rd string

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

&

 

 

 

&

w

&

w

 

&

 

 

# w

Regular tuning

 

 

 

 

 

 

Regular tuning

 

 

 

 

 

 

&

w

Fa = F

 

 

&

# w

 

So# = G#

 

 

 

w

 

&

 

w

Re = D

4th string

 

 

 

 

 

&

Si = B

2nd string

When the tuning function is active, the parameter cursor LEDs serve as tuning meter, designed to enhance tuning precision during fine adjustments.

Turning tuning function off

If you do not want to activate the tuning function in Bypass

mode, press the STORE and EDIT keys simultaneously for Pitch is too high Correctly tuned Pitch is too low more than one second in Play mode. The tuning function will be turned off, and this setting will be stored even when the power is turned off. When you turn the function off, the display will show "tunEr oFF" (tuning function off).

To turn the tuning function on, press the same keys simultaneously again. The display will show "tunEr on" (tuning function on).

NOTE: Please note that the tuning function may not operate properly if other effect modules between the guitar and the 507 are on.