Quantum SCALAR I6000, SCALAR I2000 Manual

5 (1)
6-01159-04
Scalar Library
Basic SNMP Reference Guide Basic SNMP Reference Guide
Quantum Scalar i2000 / i6000 Library
Quantum Scalar
i
2000 / i6000 Library
Scalar i2000 / i6000 Basic SNMP Guide, 6-01159-04, May 2010, Made in USA. Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied, including
but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice.
COPYRIGHT STATEMENT
Copyright 2010 by Quantum Corporation. All rights reserved. Your right to copy this manual is limited by copyright law. Making copies or adaptations without prior written
authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of the law.
TRADEMARK STATEMENT
Quantum, DLT, DLTtape, the Quantum logo, and the DLTtape logo are all registered trademarks of Quantum Corporation.
SDLT and Super DLTtape are trademarks of Quantum Corporation. Other trademarks may be mentioned herein which belong to other companies
Published: May 2010 Document Number: 6-01159-04 Rev A

Contents

1 About This Guide and Your Product 1
Explanation of Symbols and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Other Documents you Might Need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Getting More Information or Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Description 5
SNMP Functionality Available to External Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Accessing SNMP Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SNMP Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 SNMP Queries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Library Identification 7
Product Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Logical Library Name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Library Status and Health 9
Drive Online/Offline Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Drive Overall Health . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Physical Library Online/Offline State. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Robotics Readiness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Library Main Door Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Import/Export Station Door Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Partition Online/Offline Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Overall Library Health: RAS Subsystem Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5 SNMP Traps 13
ADIC Intelligent Storage MIB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Trap # 500: startupSequenceCompleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Trap # 501: shutdownSequenceInitiated. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Scalar i2000Basic SNMP Reference Guide iii
ADIC Management MIB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Trap # 101: physLibraryOnlineStatusChange. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Trap # 102: physLibraryDoorStatusChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Trap # 103: ieStationDoorStatusChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Trap # 110: rcuReady . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Trap # 111: rcuNotReady . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Trap # 204: logicalLibraryOnlineStatusChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
RAS System Status Change Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Trap # 400: connectivityGroupStatusChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Trap # 401: controlGroupStatusChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Trap # 402: coolingGroupStatusChange. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Trap # 403: drivesAndMediaGroupStatusChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Trap # 404: powerGroupStatusChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Trap # 405: roboticsGroupStatusChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
A MIBs Implemented 17
ADIC Intelligent Storage MIB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 ADIC Management MIB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 SANMgr Proxy MIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Reference MIBs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
B Variables and Traps Quick Reference 19
iv Contents

About This Guide and Your Product

WARNING
CAUTION
Note
This reference guide describes the basic usage of the Sim ple Netw or k Ma nag em e nt Pro to co l (SNM P) to acquire alert information from the Scalar® i2000 / i6000 library. Focus is placed on the most critical information available through Traps and Management Information Base (MIB) queries. For information about the Scalar i2000 / i6000 library, itself, refer to the Scalar i6000 User’s Guide. For information on integrating MIBs into a SNMP management application, contact your software vendor.
The information presented in this document represents the most commonly requested MIB objects and SNMP Traps needed to monitor the Scalar i2000 / i6000 from a network management tool. For more information about the Scalar i2000 / i6000 MIBs, contact technical support.
This basic SNMP reference is written for library customers, partners, third party management software developers, and other parties interested in integrating the Scalar i2000 / i6000 library with commercial management frameworks.
This document assumes the reader has a working knowledge of SNMP. The reader should be able to compile a MIB on their specific framework application, perform SNMP GET operations, as well as understand how to collect Traps and filter them for information.

Explanation of Symbols and Notes

The following symbols appear throughout this document to highlight important information.
INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, COULD RESULT IN DEATH OR BODILY INJURY.
Indicates a situation that may cause possible damage to equipment, loss of data, or interference with other equipment.
Indicates important information that helps you make better use of your system.
Scalar i2000 / i6000 Basic SNMP Reference Guide 1

Other Documents you Might Need

Note
The following documents are also available for this product. These documents can be found on the prod uct CD or at www.quantum.com/support
Scalar i6000 User’s Guide (6-00421-xx)
Release Notes are also available for this product. The Relea se Notes describe changes to your system or firmware since the last release, provide compatibility information, and discuss any known issues and workarounds. The Release Notes can be fo und in the product box or at www.quantum.com/support

Getting More Information or Help

More information about this product is available on the Service and Support website at
www.quantum.com/support
including answers to frequently asked questions (FAQs). You can also access software, firmware, and drivers through this site.
For further assistance, or if training is desired, contact Quantum:
. The Service and Support Website contains a collection of information,
.
Global Call Handling: 1-800-284-5101 For additional contact information: www.quantum.com/support To open a Service Request: www.quantum.com/osr
For the most updated information on Quantum Global Services, please visit: www.quantum.com/support
2 About This Guide and Your Product
Scalar i2000 / i6000 Basic SNMP Reference Guide 3
4 About This Guide and Your Product
Loading...
+ 18 hidden pages