Contents

Purpose of This Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

New Features and Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Compatibility and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Resolved Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Known Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Contacting Quantum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Purpose of This Release

The Scalar i2000/i6000 i8.1.2 release includes new features and enhancements that extend its capabilities. These release notes describe these new features and enhancements, as well as currently known issues and issues that were resolved for this release of the product. These notes also provide drive and auxiliary firmware compatibility information. Visit http://www.quantum.com for additional information about Scalar i2000 / i6000 and previous releases.

© 2011 Quantum Corporation. All rights reserved.

6-66883-05 Rev A, February 2011

Quantum, the Quantum logo, DLT, DLTtape, the DLTtape logo, SuperLoader, Scalar, StorNext, and DXi are registered trademarks of Quantum Corporation, registered in the U.S. and other countries. All other trademarks are the property of their respective companies. Specifications are subject to change without notice.

Quantum SCALAR I6000 I8.1.2, SCALAR I2000 I8.1.2 Manual

Release Notes

6-66883-05 Rev A

February 2011

New Features and Enhancements

i6000 i8.1.2

i6000 i8.1.1

i6000 i8.1

This release resolves issues in the i8.1, i8.1.1, and i8.1.2 releases.

In regards to the i8.1 release, the Scalar i6000 Addendum contains detailed information on the new features.

The i8.1.2 release provides resolution to two known issues. See Resolved Issues on page 4 for more information.

The i8.1.1 release provides further enhancements to the Control Path Failover functionality introduced in the i8.1 release. See Resolved Issues on page 4 for all resolved issues related to this release.

IBM LTO-5 Drive Support

The Scalar i6000 supports the IBM LTO-5 FC single port drive.

Control Path Failover Support

The Scalar i6000 provides support for configuring the HP LTO-5 drive for control path failover. To configure control path failover drives, you must have a Storage Networking License (SNW).

RSA Key Manager (RKM)

The Scalar i6000 now supports RKM functionality for encryption-capable HP LTO drives. To use the RKM functionality, you must have an EKM license key.

2

New Features and Enhancements

Release Notes

6-66883-05 Rev A

February 2011

Compatibility and Support

Encryption and Q-EKM

 

 

 

 

 

and SKM Drive Support

 

 

 

 

 

Encryption

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option

HP LTO-4

IBM LTO-4

HP LTO-5

IBM LTO-5

 

 

 

 

 

 

 

 

 

Application

Supported

Supported

Supported

Supported

 

 

Managed

 

 

(i6000 only)

(i6000 only)

 

 

Encryption

 

 

 

 

 

 

 

 

 

 

 

 

 

Q-EKM

Not

Requires

Not

Requires

 

 

 

Supported

EKM License

Supported

EKM License

 

 

 

 

 

 

 

 

 

SKM

Requires EKM

Not

Requires

Not

 

 

 

License

Supported

EKM License

Supported

 

 

 

 

 

 

 

 

 

RKM

Requires EKM

Not

Requires

Not

 

 

(i6000 only)

License

Supported

EKM License

Supported

 

 

 

 

 

 

 

Compatibility Matrix See the following table for information on drive and auxiliary firmware compatibility with this release of Scalar i2000/i6000. This information is current as of this product releasee. For the most up to date information on Quantum Global Services, please visit: http://www.quantum.com.

 

 

Drive Firmware

 

 

i8.1.2 Release

 

Library Firmware: 607A.GS05301

 

 

Component

Firmware Version

 

 

LMC Remote Client

5.1.13

Drive Types

 

 

 

Quantum SDLT 320 (SCSI)

v941

Quantum SDLT 600 (FC)

v531

Quantum DLT-S4

v422

IBM LTO-1 (SCSI)

5AU1

 

 

IBM LTO-1 (FC)

5AU1

 

 

 

IBM LTO-2

(SCSI)

A4N0

 

 

 

IBM LTO-2

(FC)

A4N0

 

 

 

IBM LTO-3

(FC) 2 Gb

93GM

 

 

 

IBM LTO-3

(FC) 4 Gb

93GM

 

 

 

Compatibility and Support

3

Release Notes

6-66883-05 Rev A

February 2011

 

 

Drive Firmware

 

 

i8.1.2 Release

 

Library Firmware: 607A.GS05301

 

 

 

Component

 

Firmware Version

 

 

 

IBM LTO-4 (FC) 4 Gb

 

A239

 

 

 

IBM LTO-5 (FC) 8 Gb

 

A6SA

 

 

 

HP LTO-3 (FC) 2 Gb

 

L67Z

 

 

 

HP LTO-3 (FC) 4 Gb

 

M69Z

 

 

 

HP LTO-4 (FC) 4 Gb

 

H5EZ

 

 

 

HP LTO-5 (FC) 8 Gb

 

I3AZ

 

 

 

UDS3 Drive Sled i2000

 

680Q.GU062

 

 

 

1. Logical serial number addressing (drive spoofing) is not supported. It is recommended that all customers move to the latest drive firmware.

2. Check with Quantum Customer Service for the latest firmware. 3. Install the LMC remote client from the Quantum Web site.

4. Install the AMC 4.6.6 Server and SAN manager remote client from the Quantum Web site.

Software Compatibility

To view a list backup software packages that have been tested for interoperability with the Scalar i2000 and Scalar i6000, refer to the Quantum Software Compatibility Guide at http://www.quantum.com/swcompguide.aspx.

Resolved Issues

 

 

This release of Scalar i2000/i6000 i8.1, i8.1.1, and i8.1.2 firmware resolved the

 

 

following issues:

 

 

 

Change

Service

 

Request

Request

Description

Number

Number

 

 

 

 

 

 

607A.GS05301

 

 

 

31338

 

Input from second (non-existent) picker is causing cold boot issue where robot would not

 

 

come ready.

 

 

 

31572

 

Phantom drives are displayed when shortening a library to a single frame.

 

 

 

 

 

606A.GS00301

 

 

 

30539

 

The library network name cannot contain more than 30 characters.

 

 

 

30539

 

The library network name cannot contain more than 30 characters.

 

 

 

4

Resolved Issues

 

 

Release Notes

 

 

6-66883-05 Rev A

 

 

February 2011

 

 

 

Change

Service

 

Request

Request

Description

Number

Number

 

 

 

 

30587

 

When the topology is changed on a CPF secondary inactive drive the system produces a

 

 

RAS ticket.

 

 

 

30588

 

After a speed change on the CPF primary drive, the host loses drive access.

 

 

 

30590

 

Logical serial number addressing spontaneously disabled after upgrading from i8.0.1 to

 

 

i8.1

 

 

 

 

 

605A.GS07401

 

 

 

20621

 

TUR is lost following Target reset.

 

 

 

29426

 

A tape with no clutch (gets TA55) or TA4 gets invalid CM scan results when running MeDIA

 

 

Full scan with continue on error.

 

 

 

28580

1121736

Target reset is received while writing data results in lost devices.

 

1113800

 

 

 

 

28631

1118228

FCB6404 - Upgrade QLogic Microcode to 3.03.26

 

 

 

28663

1120564

LUN reset received while writing data results in lost devices.

 

1148758

 

 

 

 

28678

1115150

LSI fiber controller firmware failed resulting in I/O fail (IOC is in fault state. Fault Code =

 

 

2215)

 

 

 

29320

1018764

FC blade ethernet interface has Failed - memory leak confirmed.

 

1024756

 

 

1053450

 

 

1080524

 

 

1100730

 

 

1119412

 

 

1107096

 

 

1124992

 

 

 

 

29418

1118244;

Drive brick firmware auto-update settings are being reset by the MCB at firmware update

 

1147748

to 6.6

 

 

 

29437

1143964

Need to be able to enter a fully qualified DNS name for the library name.

 

 

 

29748

1143538

MCB and FCB SOIP connection failure loop results in FC blade cannot connect library LUNs.

 

1170050

 

 

1176098

 

 

 

 

29821

1167054

i6k i8.01 FW Upgrade LTO-5 Drive FW will not upgrade. I27z is the minimum level to

 

 

properly work with EEB/LTO5 drives.

 

 

 

29937

1170674

SKM - RAS ticket now instructs to back up keys, plus mentions that the LME can be

 

 

enabled for the partition (s).

 

 

 

30216

1177632

The "Pre 600A.X CF Replacement.." menu option should always be available, even if the

 

 

robot is down.

 

 

 

30242

1178196

Kernel oops in vcm during snapshot process

 

 

 

Resolved Issues