1 Introduction
1.1 Instrument description
The propeller rod stirrer 802 Stirrer is controlled by a Touch Control or a
PC software.
It however has its own control. The stirring rate is set by a controller.
The 802 Stirrer can be connected to a titration stand, a tower of a sample
changer or directly to a sample changer.
1.2 About the documentation
CAUTION
1 Introduction
Please read through this documentation carefully before putting the
instrument into operation. The documentation contains information
and warnings which the user must follow in order to ensure safe operation of the instrument.
1.2.1 Symbols and conventions
The following symbols and styles are used in this documentation:
Cross-reference to figure legend
The first number refers to the figure number, the
second to the instrument part in the figure.
Instruction step
Carry out these steps in the sequence shown.
Warning
This symbol draws attention to a possible life hazard
or risk of injury.
Warning
This symbol draws attention to a possible hazard due
to electrical current.
Warning
This symbol draws attention to a possible hazard due
to heat or hot instrument parts.
■■■■■■■■
1
1.3 Safety instructions
1.3 Safety instructions
1.3.1 General notes on safety
WARNING
This instrument may only be operated in accordance with the specifications in this documentation.
■■■■■■■■■■■■■■■■■■■■■■
Warning
This symbol draws attention to a possible biological
hazard.
Caution
This symbol draws attention to a possible damage of
instruments or instrument parts.
Note
This symbol marks additional information and tips.
This instrument has left the factory in a flawless state in terms of technical
safety. To maintain this state and ensure non-hazardous operation of the
instrument, the following instructions must be observed carefully.
1.3.2 Electrical safety
The electrical safety when working with the instrument is ensured as part
of the international standard IEC 61010.
Only personnel qualified by Metrohm are authorized to carry out service
work on electronic components.
Never open the housing of the instrument. The instrument could be
damaged by this. There is also a risk of serious injury if live components
are touched.
There are no parts inside the housing which can be serviced or replaced
by the user.
WARNING
WARNING
■■■■■■■■
2
■■■■■■■■■■■■■■■■■■■■■■
1 Introduction
Mains voltage
WARNING
An incorrect mains voltage can damage the instrument.
Only operate this instrument with a mains voltage specified for it (see
rear panel of the instrument).
Protection against electrostatic charges
WARNING
Electronic components are sensitive to electrostatic charges and can be
destroyed by discharges.
Always pull the mains cable out of the mains connection socket before
connecting or disconnecting electrical appliances on the rear panel of
the instrument.
1.3.3 Working with liquids
CAUTION
Periodically check all system connections for leaks. Observe the relevant
regulations in respect to working with flammable and/or toxic fluids
and their disposal.
1.3.4 Flammable solvents and chemicals
WARNING
All relevant safety measures are to be observed when working with
flammable solvents and chemicals.
■Set up the instrument in a well-ventilated location (e.g. laboratory
flue).
■Keep all sources of flame far from the workplace.
■Clean up spilled fluids and solids immediately.
■Follow the safety instructions of the chemical manufacturer.
■■■■■■■■
3
1.3 Safety instructions
1.3.5 Recycling and disposal
This product is covered by European Directive 2002/96/EC, WEEE – Waste
from Electrical and Electronic Equipment.
The correct disposal of your old equipment will help to prevent negative
effects on the environment and public health.
More details about the disposal of your old equipment can be obtained
from your local authorities, from waste disposal companies or from your
local dealer.
■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■
4
■■■■■■■■■■■■■■■■■■■■■■
1
2
2 Device overview
2.1 802 Stirrer
2 Device overview
Figure 1802 Stirrer
Connector plug
1
For connecting the propeller stirrer to the
stirrer connector of a device or to a controller.
Metal rod
2
For fastening a stirring propeller.
■■■■■■■■
5
2.2 802 Stirrer with its own control
1
2
3
4
5
6
7
8
9
10
2.2 802 Stirrer with its own control
■■■■■■■■■■■■■■■■■■■■■■
Drive of the propeller stirrer
1
Stirring propeller (6.1909.0104)
3
Switching contacts
5
The stirrer is switched on by a suitably
attached electrode holder.
Figure 2802 Stirrer with its own control
Electrode holder (6.2021.020)
2
Support rod (6.2016.070)
4
Length 40 cm
Controller (6.2137.000)
6
For controlling the stirring rate
■■■■■■■■
6
■■■■■■■■■■■■■■■■■■■■■■
2 Device overview
Rotary wheel
7
For setting the stirring rate. If the end of the
scale is reached, turn to the other end in
order to readjust the scale.
Connector plug
9
For connecting the propeller stirrer.
Clamping screw
8
For fixing the positioning height of the
6.2137.000 rotary controller on the support
rod.
Connector plug
10
For connecting a power supply:
EU 230V / 9V DC
USA 110V / 9V DC
■■■■■■■■
7
3.1 Setting up the instrument
3 Installation
3.1 Setting up the instrument
3.1.1 Packaging
The instrument is supplied in highly protective special packaging together
with the separately packed accessories. Keep this packaging, as only this
ensures safe transportation of the instrument.
3.1.2 Checks
Immediately after receipt, check whether the shipment has arrived complete and without damage by comparing it with the delivery note.
3.1.3 Location
The instrument has been developed for operation indoors and may not be
used in explosive environments.
■■■■■■■■■■■■■■■■■■■■■■
Place the instrument in a location of the laboratory which is suitable for
operation, free of vibrations, protected from corrosive atmosphere, and
contamination by chemicals.
The instrument should be protected against excessive temperature fluctuations and direct sunlight.
■■■■■■■■
8
■■■■■■■■■■■■■■■■■■■■■■
1
2
3.2 Mounting the 802 Stirrer to the titration stand
Mounting the propeller stirrer as follows:
Insert the propeller stirrer 802 Stirrer without the stirring propeller
1
from above into the center opening of the electrode holder.
Plug the stirring propeller from below to the propeller stirrer.
2
3 Installation
3.3 Connecting the 802 Stirrer to the titration stand
Connect the propeller stirrer as follows:
Connect the cable of the 802 Stirrer to the corresponding stirrer con-
1
nector (with stirrer symbol) of the titration stand.
■■■■■■■■
9
3.4 Connecting the 802 Stirrer to the sample changer
Ind.
Ref.
Temp.
Remote
MSB
USB
Pol.
Made by Metrohm Switzerland
a)
b)
■■■■■■■■■■■■■■■■■■■■■■
3.4 Connecting the 802 Stirrer to the sample changer
Connecting the propeller stirrer directly to the sample
changer
■■■■■■■■
10
Connect the propeller stirrer as follows:
Connect the cable of the 802 Stirrer to the stirrer connector (with
1
stirrer symbol) on the rear of the tower (a) or directly to the sample
changer (b).
■■■■■■■■■■■■■■■■■■■■■■
MSB
3.804.300X
USB 1
Contr.
MSB 2
MSB 3
3 Installation
Connecting the propeller stirrer with the titration stand to
the sample changer
Connect the propeller stirrer with the titration stand as follows:
Exit the control software.
1
Connect the connection cable of the titration stand to one of the
2
sockets marked with MSB on the rear of the control device.
Connect the propeller stirrer to the stirrer socket (with stirrer symbol)
3
of the titration stand.
Start the control software.
4
■■■■■■■■
11
4.1 Rotational speed
4 Technical specifications
4.1 Rotational speed
■■■■■■■■■■■■■■■■■■■■■■
Maximum rota-
±2050...2250 U/min
tional speed
Setting of the
±15 steps
rotational speed
Increase of rota-
±140...150 U/min
tional speed per
step
4.2 Power supply
Voltage
Power consumption
FuseElectronic overload protection
+12 V, -12 V, +5 V
4 W
4.3 Safety specifications
Design and testing
■EN/IEC 61010-1:2001
■UL 61010-1: 2004
■CSA-C22.2 No. 61010-1: 2004
■Degree of protection IP40
■Protection class III
This is to certify the conformity to the standard specifications for electrical
appliances and accessories, as well as to the standard specifications for
security and to system validation issued by the manufacturing company.
■■■■■■■■■■■■■■■■■■■■■■
Name of commodity
Electromagnetic
compatibility
Safety specificationsEN/IEC 61010-1: 2001, UL 61010-1: 2004,
802 Stirrer
Rod stirrer for the connection to Metrohm instruments. The 802 Rod
Stirrer for titrations, pH/ion measurements and conductivity measurements is a low-voltage instrument.
This instrument has been built and has undergone final type testing
according to the standards:
CSA-C22.2 No. 61010-1: 2004, degree of protection IP40, protection
class III
This instrument meets the requirements of the CE mark as contained in
the EU directives 2006/95/EC (LVD), 2004/108/EC (EMC). It fulfils the following specifications:
EN 61326-1Electrical equipment for measurement, control
and laboratory use – EMC requirements
EN 61010-1Safety requirements for electrical equipment for
Metrohm Ltd. is holder of the SQS certificate ISO 9001:2000 Quality management system for development, production and sales of instruments
and accessories for ion analysis.
Herisau, 6 January, 2009
D. Strohm
Vice President, Head of R&D
5.2 Quality Management Principles
Metrohm Ltd. holds the ISO 9001:2000 Certificate, registration number
10872-02, issued by SQS (Swiss Association for Quality and Management
Systems). Internal and external audits are carried out periodically to assure
that the standards defined by Metrohm’s QM Manual are maintained.
The steps involved in the design, manufacture and servicing of instruments
are fully documented and the resulting reports are archived for ten years.
The development of software for PCs and instruments is also duly documented and the documents and source codes are archived. Both remain
the possession of Metrohm. A non-disclosure agreement may be asked to
be provided by those requiring access to them.
The implementation of the ISO 9001:2000 quality management system is
described in Metrohm’s QM Manual, which comprises detailed instructions on the following fields of activity:
Instrument development
The organization of the instrument design, its planning and the intermediate controls are fully documented and traceable. Laboratory testing
accompanies all phases of instrument development.
A. Dellenbach
Head of Quality Management
Software development
Software development occurs in terms of the software life cycle. Tests are
performed to detect programming errors and to assess the program’s
functionality in a laboratory environment.
Components
All components used in the Metrohm instruments have to satisfy the quality standards that are defined and implemented for our products. Suppliers of components are audited by Metrohm as the need arises.
■■■■■■■■
15
5.3 Warranty (guarantee)
Manufacture
The measures put into practice in the production of our instruments guarantee a constant quality standard. Production planning and manufacturing
procedures, maintenance of production means and testing of components, intermediate and finished products are prescribed.
Customer support and service
Customer support involves all phases of instrument acquisition and use by
the customer, i.e. consulting to define the adequate equipment for the
analytical problem at hand, delivery of the equipment, user manuals, training, after-sales service and processing of customer complaints. The
Metrohm service organization is equipped to support customers in implementing standards such as GLP, GMP, ISO 900X, in performing Operational Qualification and Performance Verification of the system components or in carrying out the System Validation for the quantitative determination of a substance in a given matrix.
5.3 Warranty (guarantee)
■■■■■■■■■■■■■■■■■■■■■■
Metrohm guarantees that the deliveries and services it provides are free
from material, design or manufacturing errors. The warranty period is 36
months from the day of delivery; for day and night operation it is 18
months. The warranty remains valid on condition that the service is provided by an authorized Metrohm service organization.
Glass breakage is excluded from the warranty for electrodes and other
glassware. The warranty for the accuracy corresponds to the technical
specifications given in this manual. For components from third parties that
make up a considerable part of our instrument, the manufacturer's warranty provisions apply. Warranty claims cannot be pursued if the Customer
has not complied with the obligations to make payment on time.
During the warranty period Metrohm undertakes, at its own choice, to
either repair at its own premises, free of charge, any instruments that can
be shown to be faulty or to replace them. Transport costs are to the Customer's account.
Faults arising from circumstances that are not the responsibility of
Metrohm, such as improper storage or improper use, etc. are expressly
excluded from the warranty.
■■■■■■■■
16
■■■■■■■■■■■■■■■■■■■■■■
6 Accessories
6.1 Scope of delivery
NOTE
Subject to change without notice.
6.1.1 802 Stirrer for 727 Ti Stand 2.802.0010
6 Accessories
Qty.
Order no.Description
11.802.0010802 Stirrer
Propeller stirrer
16.1909.010Stirring propeller / 96 mm
Stirring propeller, fitting length from lower edge of the ground joint:
96 mm. For usage in beakers with 702, 802 propeller stirrer.
Material:PP
16.2137.000Controller for 722/727
For 722 Rod Stirrer or 727 Ti Stand
18.802.8001MLManual 802 Stirrer
6.1.2 802 Stirrer (USA) 2.802.0011
Qty.
Order no.Description
11.802.0010802 Stirrer
■■■■■■■■
17
6.1 Scope of delivery
Qty.Order no.Description
Propeller stirrer
16.1909.010Stirring propeller / 96 mm
Stirring propeller, fitting length from lower edge of the ground joint:
96 mm. For usage in beakers with 702, 802 propeller stirrer.
Material:PP
16.1910.000Switching ring
For the 6.2137.000 controller for the 722, 803 or 727 Ti Stand, if
used with another electrode holder than the 6.2021.030.
■■■■■■■■■■■■■■■■■■■■■■
16.2119.020Power supply USA 110V/9V DC
With US mains plug. Input: 220...240 V AC. For 622, 649, 722, 728
stirrers or 727 Ti Stand. Output: 9 V DC/0.2 A.
Length (m):2
16.2137.000Controller for 722/727
For 722 Rod Stirrer or 727 Ti Stand
18.802.8001MLManual 802 Stirrer
6.1.3 802 Stirrer (EU) 2.802.0014
Qty.
Order no.Description
11.802.0010802 Stirrer
■■■■■■■■
18
Propeller stirrer
■■■■■■■■■■■■■■■■■■■■■■
Qty.Order no.Description
16.1909.010Stirring propeller / 96 mm
Stirring propeller, fitting length from lower edge of the ground joint:
96 mm. For usage in beakers with 702, 802 propeller stirrer.
Material:PP
16.1910.000Switching ring
For the 6.2137.000 controllor for the 722, 803 or 727 Ti Stand, if
used with another electrode holder than the 6.2021.030.
6 Accessories
16.2117.020Power supply EU 220V/9V DC
With Euro mains plug. Input: 220...240 V AC. For 622, 649, 722,
728, 727 Ti Stand or Spectrosense. Output: 9 V DC/0.2 A.
Length (m):2
16.2137.000Controller for 722/727
For 722 Rod Stirrer or 727 Ti Stand
18.802.8001MLManual 802 Stirrer
6.1.4 802 Stirrer for sample changer 2.802.0020
Qty.
Order no.Description
11.802.0010802 Stirrer
Propeller stirrer
■■■■■■■■
19
6.1 Scope of delivery
Qty.Order no.Description
16.1909.020Stirring propeller / 104 mm
Stirring propeller, fitting length from lower edge of the ground joint:
104 mm. For usage in beakers with 722, 802 propeller stirrer.
Material:PP
18.802.8001DEManual 802 Stirrer
6.1.5 802 Stirrer for 804 Ti Stand 2.802.0040
■■■■■■■■■■■■■■■■■■■■■■
Qty.
Order no.Description
11.802.0010802 Stirrer
Propeller stirrer
16.1909.010Stirring propeller / 96 mm
Stirring propeller, fitting length from lower edge of the ground joint:
96 mm. For usage in beakers with 702, 802 propeller stirrer.
Material:PP
18.802.8001MLManual 802 Stirrer
■■■■■■■■
20
■■■■■■■■■■■■■■■■■■■■■■
6 Accessories
6.2 Optional accessories
6.2.1 802 Stirrer 2.802.0010, 2.802.0011, 2.802.0014, 2.802.0020 und
2.802.0040
Order no.Description
6.1909.050Stirring propeller for 120 mL beakers
Stirring propeller for the usage of the 802 Stirrer with a sample rack for 120 mL
beakers (6.1459.300).
Material:ETFE
Length (mm):111
6.1909.060Stirring propeller (intense)
Stirring propeller with 3 blades for intense stirring
Length (mm):104
■■■■■■■■
21
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.