96M00080
Attachment / Slit Plate / Polarizing Filter for the PZ-G Series
Instruction Manual
● List of attachments / polarizing filters
● OP-85136 (attachment for square type sensors)
● OP-85135 (attachment for threaded type sensors)
Name Contents Model No.
Attachment A Square type attachment × 2 pcs. OP-85136
Attachment B Threaded type attachment × 2 pcs. OP-85135
Slit plate set 0.5 mm, 1 mm, 2 mm × 3 pcs. each OP-85137
Polarizing filter A (red) Red polarizing filter × 2 pcs. OP-85138
Polarizing filter B (infra red) Infrared polarizing filter × 3 p cs. OP-85139
A slit plate and polarizin g filter can be installed in the thrubeam type sensors (PZ-G51/ G52 Series).
Mount the slit plate and polarizing filter on the ma in body after assemb ling the attachmen t using the
following procedures. (Th e slit plate and pola rizing filter can be mount ed simultaneous ly.)
Important
Before use, be sure to remove the protective seal from both sides of the polarizing filter.
* The slit plate and polarizing filter are optional.
① A ssembling the attachment ②
Attachment
Cover
Slit
Polarizing filte
late
*When removing the cover,
use a screwdriver to hold
the hook down.
Mounting onto the main body
Attachment with the slit plate
and polarizing mounted
The slit plate can be
mounted vertically.
Photoelectric sensor head
* The slit plate and polarizing filter are optional.
① A ssembling the attachment ②
Attachment
Slit plate
Cover
Polarizing filte
* When removing the cover,
use a screwdriver to hold
the hook down.
Mounting onto the main body
Attachment with the slit plate and
polarizing filter mounted
The slit plate can be
mounted verticall
Photoelectric sensor head
.
Note
• Mount the slit plate and polar izing filter at the following position.
• Receiver ..................................................Upper portion
• PZ-G51 Series transmitter ......................Upper portion
• PZ-G52 Series transmitter ......................Upper/lower portions
Mount only
on the upper
portion
PZ-G51/G52 receiver
• When mounting the slit plate and p olarizing filter on the thrube am type sens ors (PZ-G51/52
Series) make sure the transmitter and receiver are mounted facing the same direction.
In addition, if a sensor is mounted adjacent to the existing one, mount th e sensors so that
they face the opposite direction.
Mount only
on the upper
portion
PZ-G51 transmitter PZ-G52 transmitter
Mount on
both the
upper/lower
Example: When interference prevention is carried out for 4 sets
Transmitter
Transmitter
Receiver
Receiver
Receiver
Transmitter
Transmitter
● OP-85137 (slit plate set)
Three types of slit plates with varying widths are available. Select according to your detection purposes
from the following list.
Receiver
Contents Slit plate Slit plate + polarizing filte r
Slit plate size (mm) 0.5×5.0 1.0×5.0 2.0×5.0
No slit
0.5×5.0 1.0×5.0 2.0×5.0
plate
Color of slit plate Black Blue Gray — Black Blue Gray
Detecting
distance
(m)
PZ-G51
Series
PZ-G52
Series
1 2.5 5 9 0.5 1.5 3
2.5 5.5 10 1 5 1 2 5